Glucose oxidase-based enzyme immobilised on tapered optical fibre for reliability improvement in selective glucose sensing

被引:7
作者
Aziz, M. S. [1 ,2 ,3 ]
Shamsudin, M. S. [1 ,4 ]
Fahri, M. A. S. A. [5 ]
Syuhada, A. [1 ]
Ibrahim, R. K. Raja [1 ,2 ]
Bakhtiar, H. [1 ,2 ]
Harun, S. W. [3 ]
机构
[1] Univ Teknol Malaysia UTM, Fac Sci, Dept Phys, Skudai 81310, Johor Dt, Malaysia
[2] Univ Teknol Malaysia UTM, Laser Ctr, Ibnu Sina Inst Sci & Ind Res, Skudai 81310, Johor Dt, Malaysia
[3] Univ Malaya, Fac Engn, Dept Elect Engn, Photon Engn Lab, Kuala Lumpur 50603, Malaysia
[4] Univ Southampton Malaysia UoSM, Fac Engn & Phys Sci, Sch Engn, Iskandar Puteri 79200, Johor Dt, Malaysia
[5] Univ Malaya UM, Photon Res Ctr, Kuala Lumpur 50603, Malaysia
来源
OPTIK | 2022年 / 259卷
关键词
Glucose sensor; Glucose oxidase; Immobilisation; Sensitivity; Selectivity; Fibre sensor; SURFACE-PLASMON RESONANCE; GRAPHENE OXIDE; GOLD NANOPARTICLES; SENSOR;
D O I
10.1016/j.ijleo.2022.168970
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical fibre-based sensing technology is considered as one of the uprising fields in photonics. Numbers of different fibre-based devices have been fabricated to systematically detect the element of interest, with the majority of the research works being focused on the selectivity and sensitivity of the sensor. In this research, a specific method of developing the sensor is demon-strated. The flame-brush technique was used on multimode fibre (MMF) to obtain an a tapered sensing structure with a waist diameter of 22.60 mu m. The tapered region was coated with glucose oxidase (GOD) by silanisation and enzyme immobilisation processes. The surface was charac-terised by fluorescent microscopy, FTIR spectroscopy, FESEM, and EDX analysis. The optimisation of GOD-coating was done by comparing the GOD coated surface with bare (uncoated) fibre and second by differentiating the pH-value of the GOD enzyme. Coated fibre exhibited higher sensitivity compared to bare tapered fibre. The values are S-coated = (5.01 +/- 0.72) x 10(-3) a.u. (%)(-1) for coated region, and S-uncoated = (3.33 +/- 0.59) x 10(-3) a.u.(%)(-1) for uncoated region. The highest sensitivity was obtained when the GOD has a pH-value of 5 where S-pH5 = S-coated, followed by S-pH7 = (1.73 +/- 0.55) x 10(-3) a.u.(%)(-1) and S-pH3 = (0.96 +/- 0.10) x 10(-3) a.u.(%)(-1). The sensor offered good stability of similar to 8.384 x 10(-6) a.u. s(- 1) retaining 0.4% of the original intensity. The sensor also provided good selectivity in glucose sensing, for which 11.595 nm redshift was observed in the transmitted spectrum.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Low-cost optical fiber multimode interference biosensor based on a glucose sensitive Glucose-Oxidase enzyme thin-film
    Rodriguez-Rodriguez, W. E.
    Rodriguez-Rodriguez, A. J.
    Juarez-Saldivar, A.
    Zamarreno, C. R.
    Matias, I. R.
    SENSORS AND ACTUATORS REPORTS, 2025, 9
  • [22] The application of the relaxation and simplex method to the analysis of data for glucose electrodes based on glucose oxidase immobilised in an osmium redox polymer
    Flexer, V.
    Calvo, E. J.
    Bartlett, P. N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 646 (1-2) : 24 - 32
  • [23] Needle-type glucose microbiosensor based on glucose oxidase immobilised in an overoxidised polypyrrole film (an in-vitro study)
    M. Quinto
    I. Losito
    F. Palmisano
    C. G. Zambonin
    Fresenius' Journal of Analytical Chemistry, 2000, 367 : 692 - 696
  • [24] The construction of molecularly imprinted electrochemical biosensor for selective glucose sensing based on the synergistic enzyme-enzyme mimic catalytic system
    Cheng, Yujun
    Chen, Tao
    Fu, Donglei
    Liu, Maosheng
    Cheng, Zhongfa
    Hua, Yanfei
    Liu, Jingquan
    TALANTA, 2022, 242
  • [25] Glucose optical fiber sensor based on sol-gel technique with ruthenium (III) chloride hydrate and glucose oxidase enzyme
    Alvarado-Mendez, E.
    Trejo-Duran, M.
    Estudillo-Ayala, J. M.
    Andrade-Lucio, J. A.
    Avina-Cervantes, J. G.
    Perez-Garcia, A.
    Pena-Gomar, M. C.
    Zavala-Fernandez, H.
    MEDICAL PHYSICS, 2006, 854 : 157 - +
  • [26] Direct electrochemistry of glucose oxidase based on its direct immobilization on carbon ionic liquid electrode and glucose sensing
    Shangguan, Xiaodong
    Zhang, Hongfang
    Zheng, Jianbin
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (08) : 1140 - 1143
  • [27] Fabrication and Characteristic of ZnO Glucose Oxidase Enzyme Electrode Based on Flexible Substrate
    Li Jin-Hua
    Li Jing
    Fang Xuan
    Wang Xiao-Hua
    Wei Zhi-Peng
    ACTA PHYSICO-CHIMICA SINICA, 2012, 28 (06) : 1393 - 1397
  • [28] Fibre optic biosensor for the determination of D-glucose based on absorption changes of immobilized glucose oxidase
    Chudobova, I
    Vrbova, E
    Kodicek, M
    Janovcova, J
    Kas, J
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 103 - 110
  • [29] Glucose concentration determination based on silica sol-gel encapsulated glucose oxidase optical biosensor arrays
    Chang, Gang
    Tatsu, Yoshiro
    Goto, Tatsushi
    Imaishi, Hiromasa
    Morigaki, Kenichi
    TALANTA, 2010, 83 (01) : 61 - 65
  • [30] Glucose Oxidase-Based pH/ROS Dual-Sensitive Nanoparticles for Tumor Starvation and Oxidative Therapy
    Chen, Miaoxin
    Li, Gaoyang
    Li, Mengli
    Xu, Shouhong
    Liu, Honglai
    ACS APPLIED NANO MATERIALS, 2024, 7 (16) : 18932 - 18942