Free-flap monitoring with tissue-oxygen measurement

被引:31
作者
Wechselberger, G
Rumer, A
Schoeller, T
Schwabegger, A
Ninkovic, M
Anderl, H
机构
[1] Univ. Clin. Plast. Reconstr. Surg., Innsbruck
[2] Univ Klin. F. Plastiche W., A-6020 Innsbruck
关键词
D O I
10.1055/s-2007-1000228
中图分类号
R61 [外科手术学];
学科分类号
摘要
Flap monitoring by oxygen measurement with a microcatheter pO(2) probe was carried out in 17 free flaps. The probe represents a new development among monitoring methods, allowing the measurement of oxygen pressure in all types of flaps including buried Free flaps and vascularized bone grafts. Fourteen flaps survived with no problem; Three flaps with different degrees of problem are reported, and the advantages and sources of error using this monitoring method are discussed.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 17 条
[1]   COLOR FLOW ULTRASOUND FOR DELINEATING MICROSURGICAL VESSELS - A CLINICAL AND EXPERIMENTAL-STUDY [J].
AMERHAUSER, A ;
MOELLEKEN, BRW ;
MATHES, SJ ;
GOODING, G ;
GOLDSTEIN, R ;
CALLEN, P ;
FILLY, RA ;
MAY, JW .
ANNALS OF PLASTIC SURGERY, 1993, 30 (03) :193-203
[2]   EXPERIMENTAL AND CLINICAL USE OF PH MONITORING OF FREE TISSUE TRANSFERS [J].
DUNN, RM ;
KAPLAN, IB ;
MANCOLL, J ;
TERZIS, JK ;
TRENGOVEJONES, G .
ANNALS OF PLASTIC SURGERY, 1993, 31 (06) :539-545
[3]   MYOCUTANEOUS FLAP ISCHEMIA - FLOW DYNAMICS FOLLOWING VENOUS AND ARTERIAL-OBSTRUCTION [J].
HJORTDAL, VE ;
HANSEN, ES ;
HAUGE, E .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (06) :1083-1091
[4]   TISSUE OXYGEN-TENSION MEASUREMENT FOR MONITORING MUSCULOCUTANEOUS AND CUTANEOUS FLAPS [J].
HJORTDAL, VE ;
AWWAD, AM ;
GOTTRUP, F ;
KIRKEGAARD, L ;
GELLETT, S .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1990, 24 (01) :27-30
[5]   DIFFERENTIAL-EFFECTS OF VENOUS STASIS AND ARTERIAL INSUFFICIENCY ON TISSUE OXYGENATION IN MYOCUTANEOUS ISLAND FLAPS - AN EXPERIMENTAL-STUDY IN PIGS [J].
HJORTDAL, VE ;
HAUGE, E ;
HANSEN, ES .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (03) :521-529
[6]  
HJORTDAL VE, 1991, ACTA CHIR-EUR J SURG, V157, P307
[7]   AN INTRAVASCULAR OXYGEN-TENSION MONITORING DEVICE USED IN MYOCUTANEOUS TRANSPLANTS - A PRELIMINARY-REPORT [J].
HOFER, SOP ;
TIMMENGA, EJF ;
CHRISTIANO, R ;
BOS, KE .
MICROSURGERY, 1993, 14 (05) :304-309
[8]  
JENKINS S D, 1987, Journal of Reconstructive Microsurgery, V3, P281, DOI 10.1055/s-2007-1006996
[9]   MONITORS FOR THE CUTANEOUS MICROCIRCULATION [J].
JONES, BM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (05) :843-850
[10]   IS EXPERIMENTAL MUSCLE FLAP TEMPERATURE A RELIABLE INDICATOR OF ITS VIABILITY [J].
KAUFMAN, T ;
GRANICK, MS ;
HURWITZ, DJ ;
KLAIN, M .
ANNALS OF PLASTIC SURGERY, 1987, 19 (01) :34-41