Blind intubation of anaesthetised children with supraglottic airway devices AmbuAura-i and Air-Q cannot be recommended A randomised controlled trial

被引:25
|
作者
Kleine-Brueggeney, Maren [1 ,2 ]
Nicolet, Anna
Nabecker, Sabine
Seiler, Stefan
Stucki, Franziska
Greif, Robert
Theiler, Lorenz
机构
[1] Univ Hosp Bern, Inselspital, Dept Anaesthesiol & Pain Med, CH-3010 Bern, Switzerland
[2] Univ Bern, CH-3010 Bern, Switzerland
关键词
LARYNGEAL MASK AIRWAY; TRACHEAL INTUBATION; DIFFICULT-AIRWAY; ADULT PATIENTS; MANAGEMENT; ANESTHESIA; TUBE; PERFORMANCE; PRESSURE; CONDUIT;
D O I
10.1097/EJA.0000000000000261
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUNDPaediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated.OBJECTIVEEvaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q.DESIGNA randomised controlled trial.SETTINGUniversity Childrens' Hospital; September 2012 to July 2014.PATIENTSEighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50kg.INTERVENTIONSTracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation).MAIN OUTCOME MEASURESPrimary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events.RESULTSPersonal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P=0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P=0.49). Median leak pressures were 18cmH(2)O (Air-Q) and 17cmH(2)O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19cmH(2)O; P=0.66]. Air-Q insertion was slower (27 vs. 19s, P<0.001). There was no difference in fibreoptic view, or adverse events (P>0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal.CONCLUSIONVentilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used.TRIAL REGISTRATIONClinicaltrials.gov identifier: NCT01692522.
引用
收藏
页码:631 / 639
页数:9
相关论文
共 11 条
  • [1] CobraPLUS and Cookgas air-Q versus Fastrach for blind endotracheal intubation: a randomised controlled trial
    Erlacher, Wolfgang
    Tiefenbrunner, Heide
    Kaestenbauer, Thomas
    Schwarz, Sylvia
    Fitzgerald, Robert D.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (03) : 181 - 186
  • [2] A randomized trial comparing the Ambu® Aura-i™ with the air-Q™ intubating laryngeal airway as conduits for tracheal intubation in children
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Sawardekar, Amod
    Gordon, Jason
    Shah, Ravi D.
    Mukherji, Isabella I.
    Roth, Andrew G.
    Suresh, Santhanam
    PEDIATRIC ANESTHESIA, 2012, 22 (12) : 1197 - 1204
  • [3] A randomized comparison between the i-gel™ and the air-Q™ supraglottic airways when used by anesthesiology trainees as conduits for tracheal intubation in children
    Jagannathan, Narasimhan
    Sohn, Lisa
    Ramsey, Melissa
    Huang, Andrea
    Sawardekar, Amod
    Sequera-Ramos, Luis
    Kromrey, Loryn
    De Oliveira, Gildasio S.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (06): : 587 - 594
  • [4] A Comparison between the i-gel® and air-Q® Supraglottic Airway Devices Used for the Patients Undergoing General Anesthesia with Muscle Relaxation
    Massoudi, Nilofar
    Fathi, Mohammad
    Nooraei, Navid
    Salehi, Alireza
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [5] Comparison of BlockBuster laryngeal mask with Air-Q intubating laryngeal airway as a conduit for fiber-optic guided intubation in children: A prospective randomized controlled study
    Soni, Lipika
    Kumar, Kanil Ranjith
    Sinha, Renu
    Ayub, Arshad
    Patel, Nishant
    PEDIATRIC ANESTHESIA, 2024, 34 (07) : 671 - 677
  • [6] The distance between the glottis and the cuff of a tracheal tube placed through three supraglottic airway devices in children A randomised controlled trial
    Lee, Ji-Hyun
    Park, Seoyeong
    Jang, Young-Eun
    Kim, Eun-Hee
    Kim, Hee-Soo
    Kim, Jin-Tae
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (10) : 721 - 727
  • [7] FIBEROPTIC-GUIDED AND BLIND TRACHEAL INTUBATION THROUGH ILTS-D, AMBU® AURAGAIN™, AND I-GEL® SUPRAGLOTTIC AIRWAY DEVICES: A RANDOMIZED CROSSOVER MANIKIN TRIAL
    Somri, Mostafa
    Matter, Ibrahim
    Gaitini, Luis A.
    Safadi, Anan
    Hawash, Nasir
    Gomez-Rios, Manuel A.
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (01): : 25 - 32
  • [8] Evaluation of glottic view through Air-Q Intubating Laryngeal Airway in the supine and lateral position and assessing it as a conduit for blind endotracheal intubation in children in the supine position
    Pandey, Ravinder Kumar
    Subramanium, Raj Kumar
    Darlong, Vanlal
    Lekha, Chandra
    Garg, Rakesh
    Punj, Jyotsna
    Rewari, Vimi
    Bajpai, Meenu
    PEDIATRIC ANESTHESIA, 2015, 25 (12) : 1241 - 1247
  • [9] A randomized comparison between the i-gel™ and the air-Q™ supraglottic airways when used by anesthesiology trainees as conduits for tracheal intubation in children [Comparaison randomisée entre les voies aériennes supraglottiques i-gel™ et air-Q™ quand elles sont utilisées par des résidents en anesthésiologie comme conduits pour intubation trachéale chez des enfants]
    Jagannathan N.
    Sohn L.
    Ramsey M.
    Huang A.
    Sawardekar A.
    Sequera-Ramos L.
    Kromrey L.
    De Oliveira G.S.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2015, 62 (6): : 587 - 594
  • [10] Design and implementation of the AIRWAYS-2 trial: A multi-centre cluster randomised controlled trial of the clinical and cost effectiveness of the i-gel supraglottic airway device versus tracheal intubation in the initial airway management of out of hospital cardiac arrest
    Taylor, Jodi
    Black, Sarah
    Brett, Stephen J.
    Kirby, Kim
    Nolan, Jerry P.
    Reeves, Barnaby C.
    Robinson, Maria
    Rogers, Chris A.
    Scott, Lauren J.
    South, Adrian
    Stokes, Elizabeth A.
    Thomas, Matthew
    Voss, Sarah
    Wordsworth, Sarah
    Benger, Jonathan R.
    RESUSCITATION, 2016, 109 : 25 - 32