Transcatheter Valve-in-Valve Repositioning of CoreValve® Evolut™ R in Aortic Prosthesis

被引:0
作者
Azevedo, Ana Isabel [1 ]
Ladeiras-Lopes, Ricardo [1 ]
Rodrigues, Alberto [1 ]
Braga, Pedro [1 ]
Ribeiro, Vasco Gama [1 ]
机构
[1] Vila Nova de Gaia Espinho Hosp Ctr, Rua Conceicao Fernandes, P-4434502 Oporto, Portugal
关键词
Aortic Vave; Bioprosthesis; Heart Valve Prosthesis Implantation; Heart Failure;
D O I
10.5935/abc.20160007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 41-year-old man with history of surgical replacement of the aortic valve with a 21mm-Mitroflow bioprosthesis (1A), presented with functional class IV heart failure. Transesophageal echocardiography confirmed severe bioprosthesis obstruction (1B). We implanted a 23mm-CoreValve® Evolut™ R (Medtronic, Minneapolis, USA) in the aortic bioprosthesis, by transfemoral approach. The valve was recaptured and repositioned during deployment (1C-E). Immediate (1F), one (1G) and three-month (1H) transthoracic echocardiography confirmed significant reduction in transaortic gradients. The patient remained in functional class I. © 2016, Arquivos Brasileiros de Cardiologia. All rights reserved.