Performance Evaluation of Thyroid Function Tests on a Novel Chemiluminescent Microparticle Immunoassay System

被引:4
作者
Ahn, Sunyoung [1 ]
Cho, Yonggeun [1 ]
Lee, Sang-Guk [1 ]
Kim, Jeong-Ho [1 ]
机构
[1] Yonsei Univ, Dept Lab Med, Coll Med, Seoul, South Korea
关键词
GUIDELINES;
D O I
10.1093/jalm/jfaa091
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The Alinity i system (Abbott), a recently developed automated immunoassay analyzer, has a compact footprint and a throughput of 200 tests per hour. Here, we present the first performance evaluation of thyroid function test (TFT) on the Alinity i system. Methods: We performed precision, linearity, comparison, functional sensitivity, carryover, and reference interval verification of 4 hormones (Thyroid Stimulation Hormone; TSH, total T3, free T4, and total T4) using the reagents provided by the manufacturer following the guidelines of the Clinical Laboratory Standards Institute. The performance of Alinity i was compared to that of the Architect i2000 immunoassay analyzer (Abbott, US). Results: The within-laboratory coefficients of variation for all the hormones were 1.6-3.6%. Linearity was observed for all the hormones over the entire tested analytical range (R-2 >= 0.99). The results for all the evaluated hormones using Alinity i system strongly correlated (r >= 0.978) with those from Architect i2000. Functional sensitivity was lower than the lower limit of the analytical measurement range. Sample carryover was less than 1.0%. Conclusions: TFTs on the Alinity i system showed acceptable performance in terms of precision, linearity, comparison, functional sensitivity, and carryover. Therefore, this system could be a useful laboratory tool for performing TFTs.
引用
收藏
页码:367 / 377
页数:11
相关论文
共 26 条
[1]  
Baskin HJ., 2002, Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists, V8, P457, DOI 10.4158/1934-2403-8.6.457
[2]  
BECKER DV, 1993, JAMA-J AM MED ASSOC, V269, P2736
[3]   CARRY-OVER IN AUTOMATIC ANALYZERS [J].
BROUGHTON, PMG .
JOURNAL OF AUTOMATIC CHEMISTRY, 1984, 6 (02) :94-95
[4]  
Ca S., 1988, MED LAB PROD, P17
[5]  
Clinical and Laboratory Standards Institute, 2002, METHOD COMPARISON BI
[6]  
Clinical Laboratory Standarts Institute [CLSI], 2004, EVALUATION PRECISION
[7]  
CLSI, 2003, EP06A CLSI
[8]   The clinical use of thyroid function tests [J].
de Carvalho, Gisah Amaral ;
Silva Perez, Camila Luhm ;
Ward, Laura Sterian .
ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2013, 57 (03) :193-204
[9]  
Demers LM, 2002, LAB SUPPORT DIAGNOSI, V13
[10]   Progress in standardizing and harmonizing thyroid function tests [J].
Faix, James D. ;
Miller, W. Greg .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2016, 104 (03) :913S-917S