Comparative thermodynamic study of refrigerants to select the best for use in the high-temperature stage of a two-stage organic Rankine cycle for RO desalination

被引:52
作者
Kosmadakis, G. [1 ]
Manolakos, D. [1 ]
Kyritsis, S. [1 ]
Papadakis, G. [1 ]
机构
[1] Agr Univ Athens, Dept Nat Resources & Agr Engn, Athens 11855, Greece
关键词
Organic working fluids; Organic Rankine cycle; Refrigerant; RO desalination; REVERSE-OSMOSIS DESALINATION; WASTE HEAT-RECOVERY; WORKING FLUIDS; SYSTEM; ALTERNATIVES; MIXTURES; DESIGN; HFCS; HFES;
D O I
10.1016/j.desal.2008.04.016
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A comparison of many organic working fluids was made. Emphasis was given to the efficiency of the thermodynamic cycle using each working fluid, as well as its environmental impact. The thermodynamic cycle consists of two stages: high temperature and low temperature. The maximum temperature of the first one is around 137 degrees C and the second one 77 degrees C. Not all the working fluids had a critical temperature higher than 137 degrees C; therefore, not all could be used under these conditions. The study focused on 33 organic working fluids; according to various criteria that were followed, the most appropriate found was the R245fa. Although it was not the most efficient, nor produced the maximum mechanical work, it performed quite well and, in addition, its use is not restricted by any international regulations. The concept was part ofthe research within the framework ofthe project COOP-CT-2003-507997.
引用
收藏
页码:74 / 94
页数:21
相关论文
共 28 条
[1]  
*AIR COND HEAT PUM, 1998, MONTR PROT SUBST DEP
[2]   Experimental investigation on the thermal stability of some new zero ODP refrigerants [J].
Angelino, G ;
Invernizzi, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01) :51-58
[3]   GENERAL-METHOD FOR THE THERMODYNAMIC EVALUATION OF HEAT-PUMP WORKING FLUIDS [J].
ANGELINO, G ;
INVERNIZZI, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1988, 11 (01) :16-25
[4]   SELECTING A WORKING FLUID FOR A RANKINE-CYCLE ENGINE [J].
BADR, O ;
PROBERT, SD ;
OCALLAGHAN, PW .
APPLIED ENERGY, 1985, 21 (01) :1-42
[5]  
BERNATCHOU AA, 1992, SOLAR ENERGY MAT SOL, V28, P81
[6]   Properties of novel fluorinated compounds and their mixtures as alternative refrigerants [J].
Beyerlein, AL ;
DesMarteau, DD ;
Kul, I ;
Zhao, G .
FLUID PHASE EQUILIBRIA, 1998, 150 :287-296
[7]   Comparative analysis of natural and synthetic refrigerants in application to low temperature Clausius-Rankine cycle [J].
Borsukiewicz-Gozdur, Aleksandra ;
Nowak, Wladyslaw .
ENERGY, 2007, 32 (04) :344-352
[8]   Maximising the working fluid flow as a way of increasing power output of geothermal power plant [J].
Borsukiewicz-Gozdur, Aleksandra ;
Nowak, Wladyslaw .
APPLIED THERMAL ENGINEERING, 2007, 27 (11-12) :2074-2078
[9]  
CALM JM, 1997, ASHRAE NIST REFR C N
[10]   Interaction coefficients for 15 mixtures of flammable and non-flammable components [J].
Defibaugh, DR ;
Morrison, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (08) :518-523