Contrast Sensitivity Evaluation of Aspheric and Spherical Intraocular Lenses 2 Years After Implantation

被引:16
作者
Caporossi, Aldo [1 ]
Casprini, Fabrizio [1 ]
Martone, Gianluca [1 ]
Balestrazzi, Angelo [1 ]
Tosi, Gian Marco [1 ]
Ciompi, Leonardo [1 ]
机构
[1] Univ Siena, Dept Ophthalmol & Neurosurg, I-53100 Siena, Italy
关键词
POSTERIOR CAPSULE OPACIFICATION; CATARACT-SURGERY; VISUAL PERFORMANCE; GLARE DISABILITY; OPTICAL-QUALITY; HUMAN EYE; ABERRATION; ACUITY; DESIGN; SILICONE;
D O I
10.3928/1081597X-20090610-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the quality of vision with aspheric and spherical intraocular lenses (IOLs) in pseudophakic patients after long-term follow-up. METHODS: Two hundred eyes of 100 patients with bilateral cataracts were randomly assigned to receive spherical (Acrysof SN60AT [Alcon Laboratories Inc] or Sensar AR40e [Advanced Medical Optics Inc)) or aspheric IOLs (Acrysof SN60WF [Alcon] or Tecnis Z9000 [Advanced Medical Optics]). Ophthalmologic examination, including best spectacle-corrected visual acuity (BSCVA), pupil size, ocular dominance, contrast sensitivity under mesopic and photopic conditions, and wavefront analysis, was performed 2 months and 1 and 2 years after surgery. RESULTS: No statistically significant differences among the four groups in terms of age, pupil diameter, postoperative BSCVA, corneal spherical aberration, and posterior capsular opacification were noted. At all followup examinations, contrast sensitivity results showed no significant differences between the two aspheric IOLs at all spatial frequencies. Under photopic conditions, significant differences (P<.05) between spherical and aspheric IOLs were detected for spatial frequencies of 12 and 18 cycles per degree (cpd) at 2 months and 2 years and 12 cpd at 1 year. Under mesopic conditions, significant differences (P<.05) were detected between spherical and aspheric IOLs for all spatial frequencies at 2 months; all spatial frequencies except 18 cpd at 1 year; and spatial frequencies of 3, 12, and 18 cpd at 2 years. In addition, aspheric IOLs had statistical reductions in total spherical aberration at all follow-up examinations (P<.01). CONCLUSIONS: This study confirms that implantation of a modified aspheric IOL improves functional visual performance at 2 years postoperative. [J Refract Surg. 2009;25:578-590.] doi:10.3928/1081597X-20090610-03
引用
收藏
页码:578 / 590
页数:13
相关论文
共 38 条
[11]   EVALUATING VISUAL FUNCTION IN CATARACT [J].
ELLIOTT, DB .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (11) :896-902
[12]   Corneal aberrations before and after small-incision cataract surgery [J].
Guirao, A ;
Tejedor, J ;
Artal, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (12) :4312-4319
[13]  
Holladay JT, 2002, J REFRACT SURG, V18, P683
[14]   Visual performance of aspherical and spherical intraocular lenses:: Intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations [J].
Kasper, Thomas ;
Buehren, Jens ;
Kohnen, Thomas .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2022-2029
[15]   Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses - Prospective evaluation [J].
Kershner, RM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (09) :1684-1694
[16]   Rate of posterior capsule opacification in eyes with the Akreos intraocular lens [J].
Khandwala, Mona A. ;
Marjnovic, Branka ;
Kotagiri, Ajay K. ;
Teimory, Masoud .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) :1409-1413
[17]   Two year results: Sharp versus rounded optic edges on silicone lenses [J].
Kruger, AJ ;
Schauersberger, J ;
Abela, C ;
Schild, G ;
Amon, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (04) :566-570
[18]   Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery [J].
Kurz, Sabine ;
Krummenauer, Frank ;
Thieme, Hagen ;
Dick, H. Burkhard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :393-400
[19]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957
[20]   New intraocular lens for achromatizing the human eye [J].
Lopez-Gil, Norberto ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1296-1302