Use of balloon expandable transcatheter valves for valve-in-valve implantation in patients with degenerative stentless aortic bioprostheses: Technical considerations and results

被引:24
作者
Bapat, Vinayak [1 ]
Davies, William [1 ]
Attia, Rizwan [1 ]
Hancock, Jane [1 ]
Bolter, Kirsty [1 ]
Young, Christopher [1 ]
Redwood, Simon [1 ]
Thomas, Martyn [1 ]
机构
[1] St Thomas Hosp, Dept Cardiovasc Surg & Cardiol, London SE1 7EH, England
关键词
CLINICAL-APPLICATION; STENOSIS; PROSTHESIS; REPLACEMENT; SURGERY;
D O I
10.1016/j.jtcvs.2014.05.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transcatheter valve-in-valve is an accepted treatment in high-risk patients with degenerative stented bioprostheses in the aortic position. Experience in treating stentless valves is, however, limited. Our aim was to determine the feasibility and single-center outcome of balloon expandable SAPIEN valve placement in degenerated stentless aortic valve bioprostheses. Methods: From February 2010 to January 2014, 10 patients with failing stentless bioprostheses underwent transcatheter aortic valve implantation using the Edwards SAPIEN transcatheter heart valve (SAPIEN, SAPIEN XT, and SAPIEN 3) at our institution. Seven patients had valve failure due to regurgitation and three to stenosis. The mean age was 73.3 +/- 15.0 years. The mean logistic EuroSCORE was 31.8 +/- 20.3, and the Society of Thoracic Surgeons score was 7.6 +/- 5.4. Results: Technical success was achieved in 9 of 10 patients. One patient required immediate placement of a second valve owing to low placement of the first. Two intraoperative complications developed that needed additional procedures. One patient underwent immediate repair of a right ventricular perforation from a pacing lead, the other, reexploration for epicardial bleeding. No deaths occurred. The median length of stay was 8.5 days (range, 3-44). The mean follow-up was 8.1 months (range, 1-21). No late reoperations or reinterventions were required. Conclusions: Transcatheter aortic valve implantation after previous stentless aortic valve replacement is technically demanding but a safe and feasible approach. The early results were excellent, with consistent improvement in hemodynamics. Prospective long-term follow-up in larger series is needed to evaluate this technique further.
引用
收藏
页码:917 / 922
页数:6
相关论文
共 21 条
[1]   A guide to fluoroscopic identification and design of bioprosthetic valves: A reference for valve-in-valve procedure [J].
Bapat, Vinayak ;
Mydin, Izanne ;
Chadalavada, Sucharitha ;
Tehrani, Hassan ;
Attia, Rizwan ;
Thomas, Martyn .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) :853-861
[2]   Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: Technical considerations and results [J].
Bapat, Vinayak ;
Attia, Rizwan ;
Redwood, Simon ;
Hancock, Jane ;
Wilson, Karen ;
Young, Christopher ;
Thomas, Martyn .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (06) :1372-1380
[3]   Effect of Valve Design on the Stent Internal Diameter of a Bioprosthetic Valve A Concept of True Internal Diameter and Its Implications for the Valve-in-Valve Procedure [J].
Bapat, Vinayak N. ;
Attia, Rizwan ;
Thomas, Martyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) :115-127
[4]   THE STENTLESS BIOPROSTHESIS - SURGICAL CHALLENGES AND IMPLICATIONS FOR LONG-TERM DURABILITY [J].
BARRATTBOYES, BG ;
CHRISTIE, GW ;
RAUDKIVI, PJ .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 :S39-S43
[5]   Survival after transapical and transfemoral aortic valve implantation: Talking about two different patient populations [J].
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Hutter, Andrea ;
Opitz, Anke ;
Bauernschmitt, Robert ;
Lange, Ruediger .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (05) :1073-1080
[6]   Prosthetic valve selection for middle-aged patients with aortic stenosis [J].
Chikwe, Joanna ;
Filsoufi, Farzan ;
Carpentier, Alain F. .
NATURE REVIEWS CARDIOLOGY, 2010, 7 (12) :711-719
[7]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[8]   Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves Results From the Global Valve-in-Valve Registry [J].
Dvir, Danny ;
Webb, John ;
Brecker, Stephen ;
Bleiziffer, Sabine ;
Hildick-Smith, David ;
Colombo, Antonio ;
Descoutures, Fleur ;
Hengstenberg, Christian ;
Moat, Neil E. ;
Bekeredjian, Raffi ;
Napodano, Massimo ;
Testa, Luca ;
Lefevre, Thierry ;
Guetta, Victor ;
Nissen, Henrik ;
Hernandez, Jose-Maria ;
Roy, David ;
Teles, Rui C. ;
Segev, Amit ;
Dumonteil, Nicolas ;
Fiorina, Claudia ;
Gotzmann, Michael ;
Tchetche, Didier ;
Abdel-Wahab, Mohamed ;
De Marco, Federico ;
Baumbach, Andreas ;
Laborde, Jean-Claude ;
Kornowski, Ran .
CIRCULATION, 2012, 126 (19) :2335-+
[9]   Prosthesis sizing for transcatheter aortic valve implantation - Comparison of three dimensional transesophageal echocardiography with multislice computed tomography [J].
Husser, Oliver ;
Holzamer, Andreas ;
Resch, Markus ;
Endemann, Dierk H. ;
Nunez, Julio ;
Bodi, Vicente ;
Schmid, Christof ;
Riegger, Guenter A. J. ;
Goessmann, Holger ;
Hamer, Okka ;
Stroszczynski, Christian ;
Luchner, Andreas ;
Hilker, Michael ;
Hengstenberg, Christian .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) :3431-3438
[10]   Transaortic Valve-in-Valve Implantation After Previous Aortic Root Homograft [J].
Ihlberg, Leo ;
Sahlman, Antero ;
Sinisalo, Juha ;
Rapola, Janne ;
Laine, Mika .
ANNALS OF THORACIC SURGERY, 2012, 94 (05) :1718-1721