Development of biosensor based on ionic liquid and corn peroxidase immobilized on chemically crosslinked chitin

被引:26
作者
Brondani, Daniela [1 ]
Dupont, Jairton [2 ]
Spinelli, Almir [1 ]
Vieira, Iolanda Cruz [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040970 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Quim Organ, BR-91501970 Porto Alegre, RS, Brazil
关键词
Biosensor; Ionic liquid; Peroxidase; Chitin; Adrenaline; MODIFIED GOLD ELECTRODE; CARBON-PASTE ELECTRODE; PHARMACEUTICAL PREPARATIONS; INJECTION-ANALYSIS; EPINEPHRINE; CHITOSAN; CATECHOLAMINES; ACID; DOPAMINE; LINKING;
D O I
10.1016/j.snb.2008.12.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors based on the ionic liquid 1-butyl-3-methytimidazolium hexafluorophosphate (BMIPF6) were constructed in order to determine adrenaline in pharmaceuticals by square-wave voltammetry. In these biosensors Nujol was used as the binder and a corn (Zea Mays L.) homogenate as a source of peroxidase, which was immobilized in chitin chemically crosslinked with carbodiimide and glyoxal. In the presence of hydrogen peroxide, the peroxidase catalyzes the oxidation of adrenaline to the corresponding o-quinone. which is electrochemically reduced at a potential of -0.23 V vs. Ag/AgCl. The best analytical responses were obtained employing peroxidase (7.5 units mg(-1) of carbon paste), BMIPF6:Nujol (50:50%, w/w) and 0.1 mol L-1 phosphate buffer solution (pH 7.0). The analytical curves were linear for adrenaline concentrations of 9.89 x 10(-7) to 1.22 x 10(-4) mol L-1. These biosensors demonstrated long-term stability and reproducibility with a relative standard deviation of 2.0%. The recovery of adrenaline in pharmaceutical samples ranged from 97.8 to 100.8% and the results obtained using the proposed biosensors are in agreement with those using the standard method. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 34 条
[1]   Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection - Epinephrine determination in pharmaceutical products [J].
Amorim, C. G. ;
Araujo, A. N. ;
Montenegro, M. C. B. S. M. .
TALANTA, 2007, 72 (04) :1255-1260
[2]   Recent advances in cholesterol biosensor [J].
Arya, Sunil K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) :1083-1100
[3]   Novel 2,2′-[1,2-ethanediylbis(nitriloethylidyne)]-bis-hydroquinone double-wall carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid [J].
Beitollahi, Hadi ;
Mazloum-Ardakani, Mohammad ;
Ganjipour, Bahram ;
Naeimi, Hossein .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (03) :362-368
[4]   Ionic liquid-based miniature electrochemical sensors for the voltammetric determination of catecholamines [J].
Chernyshov, Denis V. ;
Shuedene, Natalia V. ;
Antipova, Erika R. ;
Pletnev, Igor V. .
ANALYTICA CHIMICA ACTA, 2008, 621 (02) :178-184
[5]   Immobilization of Candida rugosa lipase on chitosan with activation of the hydroxyl groups [J].
Chiou, SH ;
Wu, WT .
BIOMATERIALS, 2004, 25 (02) :197-204
[6]   Disposable biosensor and biocatalysis of horseradish peroxidase based on sodium alginate film and room temperature ionic liquid [J].
Ding, Caifeng ;
Zhang, Meiling ;
Zhao, Fei ;
Zhang, Shusheng .
ANALYTICAL BIOCHEMISTRY, 2008, 378 (01) :32-37
[7]   Epinephrine quantification in pharmaceutical formulations utilizing plant tissue biosensors [J].
Felix, Fabiana S. ;
Yamashita, Miyuki ;
Angnes, Lucio .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (12) :2283-2289
[8]   A green bean homogenate immobilized on chemically crosslinked chitin for determination of caffeic acid in white wine [J].
Fernandes, Suellen Cadorin ;
Zwirtes de Oliveira, Ines Rosane W. ;
Vieira, Iolanda Cruz .
ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (04) :661-668
[9]   Biosensor based on laccase and an ionic liquid for determination of rosmarinic acid in plant extracts [J].
Franzoi, Ana Cristina ;
Dupont, Jairton ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
TALANTA, 2009, 77 (04) :1322-1327
[10]  
Garrido EM, 1997, J PHARMACEUT BIOMED, V15, P845