Experiences with a self-test for Dutch breast screening radiologists: lessons learnt

被引:5
作者
Timmers, J. M. H. [1 ,2 ]
Verbeek, A. L. M. [1 ,2 ]
Pijnappel, R. M. [1 ,3 ]
Broeders, M. J. M. [1 ,2 ]
den Heeten, G. J. [1 ,4 ]
机构
[1] Natl Expert & Training Ctr Breast Canc Screening, NL-6503 GJ Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Hlth Evidence, NL-6500 HB Nijmegen, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1100 DD Amsterdam, Netherlands
关键词
Breast screening; Self-test; Feedback; Interobserver agreement; Mammography; MAMMOGRAPHY; PERFORMANCE; VARIABILITY; AGREEMENT; ACCURACY;
D O I
10.1007/s00330-013-3018-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a self-test for Dutch breast screening radiologists introduced as part of the national quality assurance programme. A total of 144 radiologists were invited to complete a test-set of 60 screening mammograms (20 malignancies). Participants assigned findings such as location, lesion type and BI-RADS. We determined areas under the receiver operating characteristics (ROC) curves (AUC), case and lesion sensitivity and specificity, agreement (kappa) and correlation between reader characteristics and case sensitivity (Spearman correlation coefficients). A total of 110 radiologists completed the test (76 %). Participants read a median number of 10,000 screening mammograms/year. Median AUC value was 0.93, case and lesion sensitivity was 91 % and case specificity 94 %. We found substantial agreement for recall (kappa = 0.77) and laterality (kappa = 0.80), moderate agreement for lesion type (kappa = 0.57) and BI-RADS (kappa = 0.45) and no correlation between case sensitivity and reader characteristics. Areas under the ROC curve, case sensitivity and lesion sensitivity were satisfactory and recall agreement was substantial. However, agreement in lesion type and BI-RADS could be improved; further education might be aimed at reducing interobserver variation in interpretation and description of abnormalities. We offered individual feedback on interpretive performance and overall feedback at group level. Future research will determine whether performance has improved. aEuro cent We introduced and evaluated a self-test for Dutch breast screening radiologists. aEuro cent ROC curves, case and lesion sensitivity and recall agreement were all satisfactory. aEuro cent Agreement in BI-RADS interpretation and description of abnormalities could be improved. aEuro cent These are areas that should be targeted with further education and training. aEuro cent We offered individual feedback on interpretative performance and overall group feedback.
引用
收藏
页码:294 / 304
页数:11
相关论文
共 26 条
  • [1] [Anonymous], BREASTSCREEN AUSTR E
  • [2] Association Between Time Spent Interpreting, Level of Confidence, and Accuracy of Screening Mammography
    Carney, Patricia A.
    Bogart, T. Andrew
    Geller, Berta M.
    Haneuse, Sebastian
    Kerlikowske, Karla
    Buist, Diana S. M.
    Smith, Robert
    Rosenberg, Robert
    Yankaskas, Bonnie C.
    Onega, Tracy
    Miglioretti, Diana L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (04) : 970 - 978
  • [3] Analysis of the results of a proficiency test in screening mammography at the CSPO of Florence: Review of 705 tests
    Ciatto S.
    Ambrogetti D.
    Morrone D.
    Rosselli Del Turco M.
    [J]. La radiologia medica, 2006, 111 (6) : 797 - 803
  • [4] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46
  • [5] Mammographic Interpretation: Radiologists' Ability to Accurately Estimate Their Performance and Compare It With That of Their Peers
    Cook, Andrea J.
    Elmore, Joann G.
    Zhu, Weiwei
    Jackson, Sara L.
    Carney, Patricia A.
    Flowers, Chris
    Onega, Tracy
    Geller, Berta
    Rosenberg, Robert D.
    Miglioretti, Diana L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : 695 - 702
  • [6] Variability in Interpretive Performance at Screening Mammography and Radiologists' Characteristics Associated with Accuracy
    Elmore, Joann G.
    Jackson, Sara L.
    Abraham, Linn
    Miglioretti, Diana L.
    Carney, Patricia A.
    Geller, Berta M.
    Yankaskas, Bonnie C.
    Kerlikowske, Karla
    Onega, Tracy
    Rosenberg, Robert D.
    Sickles, Edward A.
    Buist, Diana S. M.
    [J]. RADIOLOGY, 2009, 253 (03) : 641 - 651
  • [7] Eng J, 2012, ROC ANAL WEB BAS CAL
  • [8] Esserman L, 2002, JNCI-J NATL CANCER I, V94, P369
  • [9] Web-Based Mammography Audit Feedback
    Geller, Berta M.
    Ichikawa, Laura
    Miglioretti, Diana L.
    Eastman, David
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (06) : W562 - W567
  • [10] The "Laboratory" effect: Comparing radiologists' performance and variability during prospective clinical and laboratory mammography interpretations
    Gur, David
    Bandos, Andriy I.
    Cohen, Cathy S.
    Hakim, Christiane M.
    Hardesty, Lara A.
    Ganott, Marie A.
    Perrin, Ronald L.
    Poller, William R.
    Shah, Ratan
    Sumkin, Jules H.
    Wallace, Luisa P.
    Rockette, Howard E.
    [J]. RADIOLOGY, 2008, 249 (01) : 47 - 53