STUDY ON TEMPERATURE MEASUREMENT IN WATER-SATURATED POROUS MEDIA USING MRI

被引:1
作者
Jiang, Lanlan [1 ]
Yu, Minghao [1 ]
Song, Yongchen [1 ]
Liu, Yu [1 ]
Yang, Mingjun [1 ]
Zhou, Xinhuan [1 ]
Zhao, Yuechao [1 ]
Dou, Binlin [1 ]
Wu, Bohao [1 ]
Xue, Ziqiu [2 ]
Li, Wei Zhong [1 ]
机构
[1] Dalian Univ Technol, Minist Educ, Key Lab Ocean Energy Utilizat & Energy Conservat, Dalian 116024, Liaoning, Peoples R China
[2] Res Inst Innovat Technol Earth, Kizugawa City, Kyoto 6190292, Japan
基金
中国国家自然科学基金;
关键词
MRI; temperature maps; T-1; method; chemical shift method; CHEMICAL-SHIFT; FLOW;
D O I
10.1615/JPorMedia.v17.i4.60
中图分类号
O414.1 [热力学];
学科分类号
摘要
An attractive approach for MRI thermograph has been used to investigate temperature distribution in watersaturated porous media. A range of temperaturesensitive MRI parameters (T-1 and chemical shift) were evaluated to measure temperature distribution induced heating and cooling in water and watersaturated porous media samples. The SPRG and SE sequences were used for the T-1 method. For the SPRG sequence, the T-1 dependence is about 0.0283 and 0.001 for water and watersaturated porous media, respectively. The error results from the T-1 measurement. The T-1 dependence for porous media was smaller than that for water, so the temperature measurement in porous media was more difficult. For the SE sequence, the relationship varied with TR. Generally, the relationship dependence of temperature is higher than that with the SPGR sequence. But the method with the spin echo sequence needs a long acquisition time, which is not useful to measurement temperatures changing quickly. For the chemical shift method, there was excellent linearity for water and porous media samples. The linearity relationship was independence with respect to physical or chemical structure, in addition to good temperature sensitivity. Also the chemical shift method gave promising results even at low magnetic fields. In contrast, the chemical shift method was currently accepted as the method of choice for MR thermometry in water-based homogeneous media. The T-1 method is used for temperature measurement during fluid flow.
引用
收藏
页码:347 / 358
页数:12
相关论文
共 26 条
  • [1] Mechanism of the trickle-to-pulse flow transition in fixed-bed reactors
    Anadon, LD
    Sederman, AJ
    Gladden, LF
    [J]. AICHE JOURNAL, 2006, 52 (04) : 1522 - 1532
  • [2] [Anonymous], 2016, CARBON DIOXIDE CAPTU
  • [3] Non-invasive temperature mapping using MRI:: Comparison of two methods based on chemical shift and T1-relaxation
    Bertsch, F
    Mattner, J
    Stehling, MK
    Müller-Lisse, U
    Peller, M
    Loeffler, R
    Weber, J
    Messmer, K
    Wilmanns, W
    Issels, R
    Reiser, M
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (04) : 393 - 403
  • [4] RELAXATION EFFECTS IN NUCLEAR MAGNETIC RESONANCE ABSORPTION
    BLOEMBERGEN, N
    PURCELL, EM
    POUND, RV
    [J]. PHYSICAL REVIEW, 1948, 73 (07): : 679 - 712
  • [5] SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE
    BLUML, S
    SCHAD, LR
    STEPANOW, B
    LORENZ, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) : 289 - 295
  • [6] FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE
    BRIX, G
    SCHAD, LR
    DEIMLING, M
    LORENZ, WJ
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (04) : 351 - 356
  • [7] MAGNETIC RESONANCE-GUIDED THERMAL SURGERY
    CLINE, HE
    SCHENCK, JF
    WATKINS, RD
    HYNYNEN, K
    JOLESZ, FA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 98 - 106
  • [8] Delannoy G, 1927, SPEECH ITS FUNCTION
  • [9] DEPOORTER J, 1995, MAGN RESON MED, V34, P359, DOI 10.1002/mrm.1910340313
  • [10] High temperature CO2 capture using calcium oxide sorbent in a fixed-bed reactor
    Dou, Binlin
    Song, Yongchen
    Liu, Yingguang
    Feng, Cong
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 183 (1-3) : 759 - 765