Effects of vessel compliance on flow pattern in porcine epicardial right coronary arterial tree

被引:52
作者
Huo, Yunlong [1 ]
Choy, Jenny Susana [1 ]
Svendsen, Mark [2 ]
Sinha, Anjan Kumar [3 ]
Kassab, Ghassan S. [1 ]
机构
[1] IUPUL, Dept Biomed Engn Surg & Cellular & Integrat Physi, Indianapolis, IN 46202 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] IUPUL, Dept Med, Indianapolis, IN 46202 USA
关键词
Vessel compliance; Atherosclerosis; Wall shear stress; Finite element; HUMAN CAROTID BIFURCATION; MASS-TRANSFER MECHANISM; FLUID SHEAR-STRESS; WALL SHEAR; PULSATILE FLOW; NUMERICAL-ANALYSIS; ABDOMINAL-AORTA; BLOOD-FLOW; PERMEABILITY; ATHEROSCLEROSIS;
D O I
10.1016/j.jbiomech.2008.12.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The compliance of the vessel wall affects hemodynamic parameters which may alter the permeability of the vessel wall. Based on experimental measurements, the present study established a finite element (FE) model in the proximal elastic vessel segments of epicardial right coronary arterial (RCA) tree obtained from computed tomography. the motion of elastic vessel wall was measured by an impedance catheter and the inlet boundary condition was measured by an ultrasound flow probe. The Galerkin FE method was used to solve the Navier-Stokes and Continuity equations, where the convective term in the Navier-Stokes equation was changed in the arbitrary Lagrangian-Eulerian (ALE) framework to incorporate the motion due to vessel compliance. Various hemodynamic parameters (e.g., wall shear stress WSS, WSS spatial gradient WSSG, oscillatory shear index-OSI) were analyzed in the model. The motion due to vessel compliance affects the time-averaged WSSG more strongly then WSS at bifurcations. The decrease of WSSG at flow divider in elastic bifurcations, as compared to rigid bifurcations, implies that the vessel compliance decreases the permeability of vessel wall and may be atheroprotective. the model can be used to predict coronary flow pattern in subject-specific anatomy as determined by noninvasive imaging. Published by Elsevier Ltd.
引用
收藏
页码:594 / 602
页数:9
相关论文
共 44 条
[1]   FLOW PATTERNS AND SPATIAL-DISTRIBUTION OF ATHEROSCLEROTIC LESIONS IN HUMAN CORONARY-ARTERIES [J].
ASAKURA, T ;
KARINO, T .
CIRCULATION RESEARCH, 1990, 66 (04) :1045-1066
[2]   Relation between non-uniform hemodynamics and sites of altered permeability and lesion growth at the rabbit aorto-celiac junction [J].
Buchanan, JR ;
Kleinstreuer, C ;
Truskey, GA ;
Lei, M .
ATHEROSCLEROSIS, 1999, 143 (01) :27-40
[3]   ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS [J].
CARO, CG ;
FITZGERA.JM ;
SCHROTER, RC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046) :109-+
[4]  
Cutnell J.D., 2006, PHYSICS
[5]   VASCULAR ENDOTHELIUM RESPONDS TO FLUID SHEAR-STRESS GRADIENTS [J].
DEPAOLA, N ;
GIMBRONE, MA ;
DAVIES, PF ;
DEWEY, CF .
ARTERIOSCLEROSIS AND THROMBOSIS, 1992, 12 (11) :1254-1257
[6]  
Donea J., 1983, Computational methods for transient analysis, P473
[7]   ANATOMIC CORRELATES OF AORTIC PULSE-WAVE VELOCITY AND CAROTID-ARTERY ELASTICITY DURING ATHEROSCLEROSIS PROGRESSION AND REGRESSION IN MONKEYS [J].
FARRAR, DJ ;
BOND, MG ;
RILEY, WA ;
SAWYER, JK .
CIRCULATION, 1991, 83 (05) :1754-1763
[9]  
Glasser SP, 1997, AM J HYPERTENS, V10, P1175
[10]   Effect of passive myocardium on the compliance of porcine coronary arteries [J].
Hamza, LH ;
Dang, Q ;
Lu, X ;
Mian, A ;
Molloi, S ;
Kassab, GS .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 285 (02) :H653-H660