Disposable screen-printed edge band ultramicroelectrodes for the determination of trace amounts of nitrite ion

被引:23
作者
Chang, Jen-Lin [1 ]
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
ultramicroelectrode; disposable; nitrite; linear scan voltammetry;
D O I
10.1002/elan.200503471
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of linear scan voltammetry for sensitive determination of nitrite by using a disposable screen-printed edge band carbon ultramicroelectrode (designated as SPUME) was reported in this study. The measurement with the SPUME can be performed in solutions of low ionic strength, e.g., natural waters, because the ohmic loses are negligible. The limiting oxidation current of nitrite showed a wide linear range up to 3 mM at the SPUME. A relative standard deviation of 2.46% (n = 5) for analyzing 5 mu M nitrite indicated a detection limit (SIN = 3) of 0.38 mu M. Real sample analysis of mineral and ground water samples as well as bratwurst food product showed satisfactory results. Since the SPUME is low cost and easy for mass production, the disposable nature further offers to application in diverse field of electroanalytical chemistry.
引用
收藏
页码:941 / 946
页数:6
相关论文
共 20 条
  • [1] Rapid and selective electrochemical determination of nitrite in cured meat in the presence of ascorbic acid
    Badea, M
    Amine, A
    Benzine, M
    Curulli, A
    Moscone, D
    Lupu, A
    Volpe, G
    Palleschi, G
    [J]. MICROCHIMICA ACTA, 2004, 147 (1-2) : 51 - 58
  • [2] CHANG JL, IN PRESS ELECTROCHEM
  • [3] Dietary vitamin E and selenium and toxicity of nitrite and nitrate
    Chow, CK
    Hong, CB
    [J]. TOXICOLOGY, 2002, 180 (02) : 195 - 207
  • [4] da Silva SM, 1998, ELECTROANAL, V10, P1200, DOI 10.1002/(SICI)1521-4109(199811)10:17<1200::AID-ELAN1200>3.0.CO
  • [5] 2-5
  • [6] DASILVA SM, 1996, ELECTROANAL, V8, P1055
  • [7] Guanghan L., 1997, FOOD CHEM, V59, P583
  • [8] Ion chromatographic method for simultaneous determination of nitrate and nitrite in human saliva
    Helaleh, MIH
    Korenaga, T
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 744 (02): : 433 - 437
  • [9] Sequential flow injection spectrophotometric determination of nitrite and nitrate in various samples
    Kazemzadeh, A
    Ensafi, AA
    [J]. ANALYTICA CHIMICA ACTA, 2001, 442 (02) : 319 - 326
  • [10] FARADAIC ELECTROCHEMISTRY AT MICROCYLINDER, BAND, AND TUBULAR BAND ELECTRODES
    KOVACH, PM
    CAUDILL, WL
    PETERS, DG
    WIGHTMAN, RM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 185 (02): : 285 - 295