Patient-specific cutting guides (PSCG) are an extension of preoperative planning for total knee arthroplasty (TKA). We wanted to evaluate their contribution to postoperative lower limb alignment. This study involved primary TKA cases being performed with PSCG between 10/05/2010 and 05/03/2013 and then followed prospectively. The analysis involved the PSCG usage and postoperative measurement of the patient's HKA, medial distal femoral joint angle (MDFA) and medial proximal tibia joint angle (MPTA). Of the 104 eligible cases, 68 were included; 11 of these cases were not performed completely with the PSCG as initially planned. Thus we compared these 11 cases with the 57 where PSCG were used. The preoperative HKA in the included cases was 175.8 degrees +/- 7.8; the postoperative angles on average were 179.2 degrees +/- 2.9 for the HKA, 89.9 degrees +/- 1.6 for the MDFA and 89.0 degrees +/- 2.3 for the MPTA. The average postoperative deviation from the target values was 2.22 degrees +/- 2.14 for the HKA angle, 1.07 degrees +/- 1.15 for the MDFA and 1.66 degrees +/- 1.90 for the MPTA. There were no significant differences between the two groups in any of the measurements. The lower limb alignment goal was achieved in 50 cases (73%), with 41 of these achieved with PSCG (82%). Of the 18 cases where the target was not achieved, PSCG were used 16 times (88%). In this study cohort, lower limb alignment was not significantly closer to an HKA of 180 degrees. or achieved more often with the use of PSCG versus standard instrumentation. Since the results of the two groups can be superimposed, we found no evidence that use of PSCG improves postoperative lower limb alignment. Level of evidence: IV. Study type: Cohort. (C) 2014 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S239 / S242
页数:4
相关论文
共 32 条
[1]   Survival analysis of total knee arthroplasty at a minimum 10 years' follow-up: A multicenter French nationwide study including 846 cases [J].
Argenson, J. -N. ;
Boisgard, S. ;
Parratte, S. ;
Descamps, S. ;
Bercovy, M. ;
Bonnevialle, P. ;
Briard, J. -L. ;
Brilhault, J. ;
Chouteau, J. ;
Nizard, R. ;
Saragaglia, D. ;
Servien, E. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (04) :385-390
[2]   Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees [J].
Bali, Kamal ;
Walker, Peter ;
Bruce, Warwick .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1149-1154
[3]   Patient specific cutting blocks are currently of no proven value [J].
Barrack, R. L. ;
Ruh, E. L. ;
Williams, B. M. ;
Ford, A. D. ;
Foreman, K. ;
Nunley, R. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11) :95-99
[4]   Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty [J].
Blakeney, William G. ;
Khan, Riaz J. K. ;
Wall, Simon J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1377-1384
[5]   A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement [J].
Chareancholvanich, K. ;
Narkbunnam, R. ;
Pornrattanamaneewong, C. .
BONE & JOINT JOURNAL, 2013, 95B (03) :354-359
[6]   Evaluation of the accuracy of a patient-specific instrumentation by navigation [J].
Conteduca, Fabio ;
Iorio, Raffaele ;
Mazza, Daniele ;
Caperna, Ludovico ;
Bolle, Gabriele ;
Argento, Giuseppe ;
Ferretti, Andrea .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) :2194-2199
[7]   Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty [J].
Dutton, Andrew Quoc ;
Yeo, Seng-Jin ;
Yang, Kuang-Ying ;
Lo, Ngai-Nung ;
Chia, Kui-Un ;
Chong, Hwei-Chi .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) :2-9
[8]   Health-related quality of life in total hip and total knee arthroplasty - A qualitative and systematic review of the literature [J].
Ethgen, O ;
Bruyere, O ;
Richy, F ;
Dardennes, C ;
Reginster, JY .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05) :963-974
[9]   Coronal Alignment in Total Knee Arthroplasty Just How Important is it? [J].
Fang, David M. ;
Ritter, Merrill A. ;
Davis, Kenneth E. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :39-43
[10]  
Fehring TK, 2001, CLIN ORTHOP RELAT R, P315