Multichannel place pitch sensitivity in cochlear implant recipients

被引:22
作者
Laneau, J [1 ]
Wouters, J [1 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Lab Expt ORL, B-3000 Louvain, Belgium
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2004年 / 5卷 / 03期
关键词
cochlear implant; place pitch; sensitivity; multichannel; monopolar;
D O I
10.1007/s10162-004-4049-y
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Cochlear implant recipients perceive a rise in pitch when the site of stimulation is moved from the apex toward the base. The place pitch sensitivity is typically measured using the stimulation of single channels. However, all current cochlear implant devices stimulate multiple channels simultaneously or with pulses temporally interleaved. The primary goal of the present study is to test whether the sensitivity of a cochlear implant recipient to changes in perceived pitch associated with changes of place of excitation improves or deteriorates when the number of active channels is increased, compared with stimulation with only one active channel. Place pitch sensitivity was recorded in four Nucleus CI24 subjects as a function of number of active channels (from 1 to 8). just noticeable differences were estimated from a constant stimuli 2AFC pitch-ranking experiment with roving loudness. Reference and comparison stimuli contained the same number of active channels but were shifted one or two electrodes toward the base or toward the apex. The place pitch sensitivity was measured using monopolar stimulation at two locations along the electrode array. To minimize cues related to loudness, the multichannel stimuli were loudness balanced relative to the single-channel stimuli presented at C-level. The number of active channels did not affect place pitch sensitivity. This is consistent with a model that compares the edges of the excitation pattern irrespective of the overlap between excitation patterns. There was a significant difference in sensitivity to place pitch among subjects. The average just noticeable differences of place pitch, extrapolated from a fitting procedure, for the subjects ranged from 0.25 mm to 0.46 mm.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 35 条
[1]   DIFFERENTIAL ELECTRICAL EXCITATION OF THE AUDITORY-NERVE [J].
BLACK, RC ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 67 (03) :868-874
[2]   PITCH PERCEPTION FOR DIFFERENT MODES OF STIMULATION USING THE COCHLEAR MULTIPLE-ELECTRODE PROSTHESIS [J].
BUSBY, PA ;
WHITFORD, LA ;
BLAMEY, PJ ;
RICHARDSON, LM ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (05) :2658-2669
[3]  
Busby PA, 1996, AUDIOLOGY, V35, P8
[4]   Limitations on rate discrimination [J].
Carlyon, RP ;
Deeks, JM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2002, 112 (03) :1009-1025
[5]  
Cohen L T, 1996, Audiol Neurootol, V1, P278
[6]   Psychophysics of a prototype peri-modiolar cochlear implant electrode array [J].
Cohen, LT ;
Saunders, E ;
Clark, GM .
HEARING RESEARCH, 2001, 155 (1-2) :63-81
[7]  
Cohen W, 1996, DOWN SYND Q, V1, P1
[8]   Investigating perceptual features of electrode stimulation via a multidimensional scaling paradigm [J].
Collins, LM ;
Throckmorton, CS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 108 (05) :2353-2365
[9]   Comparison of electrode discrimination, pitch ranking, and pitch scaling data in postlingually deafened adult cochlear implant subjects [J].
Collins, LM ;
Zwolan, TA ;
Wakefield, GH .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) :440-455
[10]   Coding of the fundamental frequency in continuous interleaved sampling processors for cochlear implants [J].
Geurts, L ;
Wouters, J .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 109 (02) :713-726