Decreasing battery life in subthalamic deep brain stimulation for Parkinson's disease with repeated replacements: Just a matter of energy delivered?

被引:19
作者
Israeli-Korn, Simon Daniel [1 ,2 ]
Fay-Karmon, Tsviya [1 ,2 ]
Tessler, Steven [4 ]
Yahalom, Gilad [1 ,2 ,4 ]
Benizri, Sandra [1 ,2 ]
Strauss, Hanna [1 ,2 ]
Zibly, Zion [3 ,4 ]
Spiegelmann, Roberto [3 ,4 ]
Hassin-Baer, Sharon [1 ,2 ,4 ]
机构
[1] Sheba Med Ctr, Movement Disorders Inst, IL-5262101 Ramat Gan, Israel
[2] Sheba Med Ctr, Dept Neurol, IL-5262101 Ramat Gan, Israel
[3] Sheba Med Ctr, Stereotact & Funct Neurosurg, Radiosurg Unit, Ramat Gan, Israel
[4] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
关键词
Parkinson's disease; STN; Deep brain stimulation; IPG; Battery life; IMPLANTABLE PULSE GENERATORS; HYPERPYREXIA SYNDROME; PATIENT SATISFACTION; IMPULSE GENERATORS; MALIGNANT SYNDROME; LONGEVITY; DYSTONIA; INFECTION; NUCLEUS;
D O I
10.1016/j.brs.2019.02.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: People with Parkinson's disease (PD) treated with deep brain stimulation (DBS) with non-rechargeable implantable pulse generators (IPGs) require elective IPG replacement operations involving surgical and anesthesiologic risk. Life expectancy and the number of replacements per patient with DBS are increasing. Objective: To determine whether IPG longevity is influenced by stimulation parameters alone or whether there is an independent effect of the number of battery replacements and IPG model. Methods: PD patients treated with bilateral subthalamic DBS were included if there was at least one IPG replacement due to battery end of life. Fifty-five patients had one or two IPG replacements and seven had three or four replacements, (80 Kinetra (R) and 23 Activa-PC (R)). We calculated longevity corrected for total electrical energy delivered (TEED) and tested for the effect of IPG model and number of previous battery replacements on this measure. Results: TEED-corrected IPG longevity for the 1st implanted IPG was 51.3 months for Kinetra (R) and 35.6 months for Activa-PC (R), which dropped by 5.9 months and 2.8 months, respectively with each subsequent IPG replacement (p <10(-6) for IPG model and p <10(-3) for IPG number). Conclusions: Activa-PC (R) has shorter battery longevity than the older Kinetra (R), battery longevity reduces with repeated IPG replacements and these findings are independent of TEED. Battery longevity should be considered both in clinical decisions and in the design of new DBS systems. Clinicians need accessible, reliable and user-friendly tools to provide online estimated battery consumption and end of life. Furthermore, this study supports the consideration of using rechargeable IPGs in PD. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:845 / 850
页数:6
相关论文
共 40 条
[1]   Randomized, Blinded Pilot Testing of Nonconventional Stimulation Patterns and Shapes in Parkinson's Disease and Essential Tremor: Evidence for Further Evaluating Narrow and Biphasic Pulses [J].
Akbar, Umer ;
Raike, Robert S. ;
Hack, Nawaz ;
Hess, Christopher W. ;
Skinner, Jared ;
Martinez-Ramirez, Daniel ;
DeJesus, Sol ;
Okun, Michael S. .
NEUROMODULATION, 2016, 19 (04) :343-356
[2]   Stability of symptom control after replacement of impulse generators for deep brain stimulation [J].
Allert, Niels ;
Kirsch, Holger ;
Weirich, Waldemar ;
Karbe, Hans .
JOURNAL OF NEUROSURGERY, 2009, 110 (06) :1274-1277
[3]   A Pilot Trial of Square Biphasic Pulse Deep Brain Stimulation for Dystonia: The BIP Dystonia Study [J].
Almeida, Leonardo ;
Martinez-Ramirez, Daniel ;
Ahmed, Bilal ;
Deeb, Wissam ;
De Jesus, Sol ;
Skinner, Jared ;
Terza, Matthew J. ;
Akbar, Umer ;
Raike, Robert S. ;
Hass, Chris J. ;
Okun, Michael S. .
MOVEMENT DISORDERS, 2017, 32 (04) :615-618
[4]   Systems for deep brain stimulation: review of technical features [J].
Amon, A. ;
Alesch, F. .
JOURNAL OF NEURAL TRANSMISSION, 2017, 124 (09) :1083-1091
[5]   Parkinsonism-hyperpyrexia syndrome and deep brain stimulation [J].
Artusi, Carlo Alberto ;
Merola, Aristide ;
Espay, Alberto J. ;
Zibetti, Maurizio ;
Romagnolo, Alberto ;
Lanotte, Michele ;
Lopiano, Leonardo .
JOURNAL OF NEUROLOGY, 2015, 262 (12) :2780-2782
[6]  
Benabid AL, 1998, MOVEMENT DISORD, V13, P119
[7]   Longevity of batteries in internal pulse generators used for deep brain stimulation [J].
Bin-Mahfoodh, M ;
Hamani, C ;
Sime, E ;
Lozano, AM .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2003, 80 (1-4) :56-60
[8]  
Rocha CED, 2014, BRAZ NEUROSURG, V33, P207
[9]   Proceedings of the Fourth Annual Deep Brain Stimulation Think Tank: A Review of Emerging Issues and Technologies [J].
Deeb, Wissam ;
Giordano, James J. ;
Rossi, Peter J. ;
Mogilner, Alon Y. ;
Gunduz, Aysegul ;
Judy, Jack W. ;
Klassen, Bryan T. ;
Butson, Christopher R. ;
Van Horne, Craig ;
Deny, Damiaan ;
Dougherty, Darin D. ;
Rowell, David ;
Gerhardt, Greg A. ;
Smith, Gwenn S. ;
Ponce, Francisco A. ;
Walker, Harrison C. ;
Bronte-Stewart, Helen M. ;
Mayberg, Helen S. ;
Chizeck, Howard J. ;
Langevin, Jean-Philippe ;
Volkmann, Jens ;
Ostrem, Jill L. ;
Shute, Jonathan B. ;
Jimenez-Shahed, Joohi ;
Foote, Kelly D. ;
Shukla, Aparna Wagle ;
Rossi, Marvin A. ;
Oh, Michael ;
Pourfar, Michael ;
Rosenberg, Paul B. ;
Silburn, Peter A. ;
de Hemptine, Coralie ;
Starr, Philip A. ;
Denison, Timothy ;
Akbar, Umer ;
Grill, Warren M. ;
Okun, Michael S. .
FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2016, 10
[10]   Probabilistic mapping of deep brain stimulation effects in essential tremor [J].
Dembek, Till A. ;
Barbe, Michael T. ;
Astrom, Mattias ;
Hoevels, Mauritius ;
Visser-Vandewalle, Veerle ;
Fink, Gereon R. ;
Timmermann, Lars .
NEUROIMAGE-CLINICAL, 2017, 13 :164-173