A Microscopic Optically Tracking Navigation System That Uses High-resolution 3D Computer Graphics

被引:10
|
作者
Yoshino, Masanori [1 ]
Saito, Toki [2 ]
Kin, Taichi [1 ]
Nakagawa, Daichi [1 ]
Nakatomi, Hirofumi [1 ]
Oyama, Hiroshi [2 ]
Saito, Nobuhito [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Dept Neurosurg, Tokyo 1138655, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Clin Informat Engn, Tokyo 1138655, Japan
关键词
computer graphics; microscope; neuronavigation; IMAGE-GUIDED NEUROSURGERY; AUGMENTED REALITY; SURGERY; NEURONAVIGATION; DECOMPRESSION; REGISTRATION; EXPERIENCE; FUTURE;
D O I
10.2176/nmc.tn.2014-0278
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Three-dimensional (3D) computer graphics (CG) are useful for preoperative planning of neurosurgical operations. However, application of 3D CG to intraoperative navigation is not widespread because existing commercial operative navigation systems do not show 3D CG in sufficient detail. We have developed a microscopic optically tracking navigation system that uses high-resolution 3D CG. This article presents the technical details of our microscopic optically tracking navigation system. Our navigation system consists of three components: the operative microscope, registration, and the image display system. An optical tracker was attached to the microscope to monitor the position and attitude of the microscope in real time; point-pair registration was used to register the operation room coordinate system, and the image coordinate system; and the image display system showed the 3D CG image in the field-of-view of the microscope. Ten neurosurgeons (seven males, two females; mean age 32.9 years) participated in an experiment to assess the accuracy of this system using a phantom model. Accuracy of our system was compared with the commercial system. The 3D CG provided by the navigation system coincided well with the operative scene under the microscope. Target registration error for our system was 2.9 +/- 1.9 mm. Our navigation system provides a clear image of the operation position and the surrounding structures. Systems like this may reduce intraoperative complications.
引用
收藏
页码:674 / 679
页数:6
相关论文
共 50 条
  • [21] Development of Massive Open Online Courses Based on 3D Computer Graphics and Multimedia
    Khoroshko, Leonid L.
    Ukhov, Peter A.
    Keyno, Pavel P.
    INTERNATIONAL JOURNAL OF ENGINEERING PEDAGOGY, 2019, 9 (04): : 4 - 15
  • [22] Vision-based endoscope tracking for 3D ultrasound image-guided surgical navigation
    Yang, L.
    Wang, J.
    Ando, T.
    Kubota, A.
    Yamashita, H.
    Sakuma, I.
    Chiba, T.
    Kobayashi, E.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 205 - 216
  • [23] Why are 3D Transformations in Computer Graphics Difficult? An Analysis of a Decade of Exam Questions
    Suselo, Thomas
    Wunsche, Burkhard C.
    Luxton-Reilly, Andrew
    PROCEEDINGS OF THE 24TH AUSTRALASIAN COMPUTING EDUCATION CONFERENCE, ACE 2022, 2022, : 181 - 190
  • [24] Fully integrated 3D high-resolution multicontrast abdominal PET-MR with high scan efficiency
    Kolbitsch, Christoph
    Neji, Radhouene
    Fenchel, Matthias
    Mallia, Andrew
    Marsden, Paul
    Schaeffter, Tobias
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 900 - 911
  • [25] Evaluation of an Electromagnetic 3D Navigation System to Facilitate Endovascular Tasks: A Feasibility Study
    Sidhu, R.
    Weir-McCall, J.
    Cochennec, F.
    Riga, C.
    DiMarco, A.
    Bicknell, C. D.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (01) : 22 - 29
  • [26] Registration of high-resolution 3D atrial images with electroanatomical cardiac mapping: Evaluation of registration methodology
    Sun, YY
    Azar, FS
    Xu, CY
    Hayam, G
    Preiss, A
    Rahn, N
    Sauer, F
    Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display, Pts 1 and 2, 2005, 5744 : 299 - 307
  • [27] RECONSTRUCTION OF THE HUMAN HIPPOCAMPUS IN 3D FROM HISTOLOGY AND HIGH-RESOLUTION EX-VIVO MRI
    Adler, Daniel H.
    Liu, Alex Yang
    Pluta, John
    Kadivar, Salmon
    Orozco, Sylvia
    Wang, Hongzhi
    Gee, James C.
    Avants, Brian B.
    Yushkevich, Paul A.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 294 - 297
  • [28] An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom
    Hsu, Christina M. L.
    Palmeri, Mark L.
    Segars, W. Paul
    Veress, Alexander I.
    Dobbins, James T., III
    MEDICAL PHYSICS, 2011, 38 (10) : 5756 - 5770
  • [29] Efficacy of a Novel Augmented Reality Navigation System Using 3D Computer Graphic Modeling in Endoscopic Transsphenoidal Surgery for Sellar and Parasellar Tumors
    Goto, Yoshiaki
    Kawaguchi, Ai
    Inoue, Yuki
    Nakamura, Yuki
    Oyama, Yuta
    Tomioka, Arisa
    Higuchi, Fumi
    Uno, Takeshi
    Shojima, Masaaki
    Kin, Taichi
    Shin, Masahiro
    CANCERS, 2023, 15 (07)
  • [30] Subject specific hand and forearm musculoskeletal 3D geometries using high-resolution MR images
    Marin, Frederic
    Devos, Pierre
    Hansen, Clint
    Charleux, Fabrice
    Robert, Ludovic
    Ben Mansour, Khalil
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2019, 7 (01) : 91 - 98