Comparison of Central Corneal Thickness, Thinnest Corneal Thickness, Anterior Chamber Depth, and Simulated Keratometry Using Galilei, Pentacam, and Sirius Devices

被引:38
作者
Anayol, Mustafa A. [1 ]
Guler, Emre [2 ]
Yagci, Ramazan [3 ]
Sekeroglu, Mehmet A. [1 ]
Yilmazoglu, Meltem [1 ]
Tirhis, Hakan [1 ]
Kulak, Ali E. [2 ]
Yilmazbas, Pelin [1 ]
机构
[1] Ulucanlar Eye Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
[2] Turgut Ozal Univ, Dept Ophthalmol, Sch Med, TR-06510 Ankara, Turkey
[3] Pamukkale Univ, Dept Ophthalmol, Sch Med, Denizli, Turkey
关键词
central corneal thickness; thinnest corneal thickness; anterior chamber depth; simulated keratometry; Pentacam; Galilei; Sirius; LENS POWER CALCULATION; OPTICAL COHERENCE TOMOGRAPHY; AUTOMATIC MEASUREMENTS; REFRACTIVE SURGERY; SCHEIMPFLUG CAMERA; OCULUS PENTACAM; REPEATABILITY; SYSTEM; HR; REPRODUCIBILITY;
D O I
10.1097/ICO.0000000000000119
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim was to evaluate the agreement in the central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), and mean simulated keratometry (simK) measurements using Pentacam, Galilei, and Sirius Scheimpflug systems in normal eyes. Methods: Anterior segment measurements were performed with Pentacam, Galilei, and Sirius devices in 32 healthy subjects. The right eye of each participant was selected. Measurements obtained with the 3 systems were compared using repeated-measures analysis of variance and Bonferroni multiple comparisons test. Results: Analysis of variance determined a significant difference in the anterior segment measurements of CCT, TCT, ACD, and simK between the 3 devices (P < 0.001). Pairwise comparisons of CCT and TCT measurements were significantly different except for the comparison between Pentacam and Sirius. All pairwise comparisons for ACD were statistically significant. The pairwise comparison results for simK values showed that the Galilei and Sirius systems demonstrated better agreement with each other than with Pentacam. Conclusions: The results of this study suggest that the Pentacam, Galilei, and Sirius Scheimpflug systems should not be accepted as interchangeable for CCT, TCT, ACD, and simK in healthy subjects.
引用
收藏
页码:582 / 586
页数:5
相关论文
共 24 条
[1]   Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers [J].
De la Parra-Colin, Paola ;
Garza-Leon, Manuel ;
Barrientos-Gutierrez, Tonatiuh .
INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (01) :27-33
[2]   Mapping Corneal Thickness Using Dual-Scheimpflug Imaging at Different Stages of Keratoconus [J].
Demir, Selim ;
Ortak, Huseyin ;
Yeter, Volkan ;
Alim, Sait ;
Sayin, Osman ;
Tas, Ufuk ;
Sonmez, Baris .
CORNEA, 2013, 32 (11) :1470-1474
[3]   MULTIPLE CRITERIA FOR EVALUATING THE MAGNITUDE OF EXPERIMENTAL EFFECTS [J].
HAASE, RF ;
ELLIS, MV ;
LADANY, N .
JOURNAL OF COUNSELING PSYCHOLOGY, 1989, 36 (04) :511-516
[4]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[5]   Comparison of Corneal Thickness Measurements Using Galilei, HR Pentacam, and Ultrasound [J].
Hosseini, Hamid Reza Jahadi ;
Katbab, Asadollah ;
Khalili, Mohammad Reza ;
Abtahi, Mohammad Bagher .
CORNEA, 2010, 29 (10) :1091-1095
[6]   A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness [J].
Huang, Jinhai ;
Ding, Xixia ;
Savini, Giacomo ;
Pan, Chao ;
Feng, Yifan ;
Cheng, Dan ;
Hua, Yanjun ;
Hu, Xiuli ;
Wang, Qinmei .
OPHTHALMOLOGY, 2013, 120 (10) :1951-1958
[7]  
Javaloy J, 2004, J REFRACT SURG, V20, P29
[8]   Biometry and intraocular lens power calculation [J].
Lee, Alexander C. ;
Qazi, Mujtaba A. ;
Pepose, Jay S. .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) :13-17
[9]   Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry Mapping [J].
Li, Yan ;
Meisler, David M. ;
Tang, Maolong ;
Lu, Ake T. H. ;
Thakrar, Vishakha ;
Reiser, Bibiana J. ;
Huang, David .
OPHTHALMOLOGY, 2008, 115 (12) :2159-2166
[10]   A Comprehensive Evaluation of the Precision (Repeatability and Reproducibility) of the Oculus Pentacam HR [J].
McAlinden, Colm ;
Khadka, Jyoti ;
Pesudovs, Konrad .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) :7731-7737