Three-dimensional true-FISP imaging of the coronary arteries: improved contrast with T2-preparation

被引:81
作者
Shea, SM [1 ]
Deshpande, VS [1 ]
Chung, YC [1 ]
Li, DB [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
关键词
magnetic resonance imaging; magnetization-prepared contrast; coronary artery imaging; fast imaging; MR angiography;
D O I
10.1002/jmri.10106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of a T2-magnetization preparation scheme for improving coronary artery imaging with true fast imaging with steady-state precession (True-FISP). Materials and Methods: Simulations were performed to compare the blood-myocardium signal difference with no T2-preparation to that with various T2-preparation times (24, 40, and 60 msec) using an electrocardiogram (ECG)triggered, segmented True-FISP acquisition. Seven volunteers were imaged to evaluate the effectiveness of T2-preparation for coronary artery delineation using True-FISP and to optimize the T2-preparation time. Results: Simulations showed that T2-preparation improved the signal difference between blood and myocardium over that without T2-preparation. The optimal T2-preparation time was determined to be 40 msec. In volunteer studies, a T2-preparation time of 40 msec provided a significant improvement in contrast-to-noise ratio (CNR) between the coronary arteries and myocardium over that without T2-preparation. It also showed a significant improvement in visualizing the distal portions of the coronary arteries. Conclusion: T2-preparation improves coronary artery delineation with True-FISP. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 8 条
[1]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[2]   CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST [J].
BRITTAIN, JH ;
HU, BS ;
WRIGHT, GA ;
MEYER, CH ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :689-696
[3]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[4]   MAGNETIZATION-TRANSFER AND T-2 RELAXATION COMPONENTS IN TISSUE [J].
HARRISON, R ;
BRONSKILL, MJ ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :490-496
[5]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[6]   COMPENSATION FOR PULSE IMPERFECTIONS IN NMR SPIN-ECHO EXPERIMENTS [J].
LEVITT, MH ;
FREEMAN, R .
JOURNAL OF MAGNETIC RESONANCE, 1981, 43 (01) :65-80
[7]   BROAD-BAND HETERONUCLEAR DECOUPLING [J].
LEVITT, MH ;
FREEMAN, R ;
FRENKIEL, T .
JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (02) :328-330
[8]   ITERATIVE CARR-PURCELL TRAINS [J].
SHAKA, AJ ;
RUCKER, SP ;
PINES, A .
JOURNAL OF MAGNETIC RESONANCE, 1988, 77 (03) :606-611