Reduction of Artifact of Metallic Implant in Magnetic Resonance Imaging by Coating of Diamagnetic Material

被引:11
作者
Gao, Yanhui [1 ]
Muramatsu, Kazuhiro [1 ]
Kushibe, Atsumichi [2 ]
Yamazaki, Keita [2 ]
Chiba, Akihiko [3 ]
Yamamoto, Toru [4 ]
机构
[1] Saga Univ, Dept Elect & Elect Engn, Saga 8408502, Japan
[2] Takenaka Co, Inst Res & Dev, Ohtsuka, Inzai 2701395, Japan
[3] Tohoku Univ, Inst Mat Res, Sendai, Miyagi 9808577, Japan
[4] Hokkaido Univ, Grad Sch Hlth Sci, Sapporo, Hokkaido 0600812, Japan
关键词
Artifact; diamagnetic material; magnetic field analysis; metallic implant; MRI; paramagnetic material; MRI ARTIFACTS;
D O I
10.1109/TMAG.2009.2025774
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Metallic implants composed of paramagnetic materials, such as stainless steel ( SUS), Ti, Co-Cr-Mo alloy, etc., are widely used as artificial hip joints or aneurysm clips. When the metallic implant is placed in a uniform magnetic field of a magnetic resonance scanner, a magnetic disturbance is created due to its magnetization. This magnetic disturbance distorts the image of the metallic implant and body tissues in the magnetic resonance imaging (MRI). In order to overcome this problem, a method of coating the metallic implant with diamagnetic material has been proposed as the magnetic disturbance created by the metallic implant can be removed by the cancellation of the respective magnetizations of the paramagnetic and diamagnetic materials. But the optimal thickness of the diamagnetic coating has been obtained only for a sphere model by mathematical modeling. In this paper, the effects of a straight cylindrical hip joint model and an aneurysm clip model on the magnetic disturbance are investigated by using the magnetic field analysis of the finite element method (FEM). First, the magnetic disturbances generated by the two models made of paramagnetic material are calculated and compared with measured results. Moreover, the associations of susceptibilities chi(par) and chi(dia) of the paramagnetic and diamagnetic materials and the optimal thicknesses of the diamagnetic coating when the magnetic disturbances can be reduced for the two models are shown.
引用
收藏
页码:4837 / 4840
页数:4
相关论文
共 5 条
[1]   Cancellation of metal-induced MRI artifacts with dual-component paramagnetic and diamagnetic material: Mathematical modelization and experimental verification [J].
Chauvel, B ;
Cathelineau, G ;
Balac, S ;
Lecerf, J ;
deCertaines, JD .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06) :936-938
[2]   CALCULATION OF MRI ARTIFACTS CAUSED BY STATIC-FIELD DISTURBANCES [J].
ERICSSON, A ;
HEMMINGSSON, A ;
JUNG, B ;
SPERBER, GO .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10) :1103-1112
[3]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[4]   CT and conventional and diffusion-weighted MR imaging in acute stroke: Study in 691 patients at presentation to the emergency department [J].
Mullins, ME ;
Schaefer, PW ;
Sorensen, AG ;
Halpern, EF ;
Ay, H ;
He, J ;
Koroshetz, WJ ;
Gonzalez, RG .
RADIOLOGY, 2002, 224 (02) :353-360
[5]   The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850