Features of the NIH atlas small animal PET scanner and its use with a coaxial small animal volume CT scanner

被引:0
|
作者
Seidel, J [1 ]
Vaquero, JJ [1 ]
Pascau, J [1 ]
Desco, M [1 ]
Johnson, CA [1 ]
Green, MV [1 ]
机构
[1] NIH, Bethesda, MD 20892 USA
来源
2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS | 2002年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
ATLAS (Advanced Technology Laboratory Animal Scanner), a small animal PET scanner designed to image animals the size of rats and mice, is about to enter service on the NIH campus in Bethesda, Maryland. This system is the first small animal PET scanner with a depth-of-interaction capability and the first to use iterative resolution recovery algorithms, rather than conventional filtered back projection, for "production" image reconstruction. ATLAS is also proximate to, and co-axial with, a high, resolution small animal CT scanner. When fully integrated, spatially registered PET and CT images of each animal will be used to correct the emission data for radiation attenuation and to aid in target identification. In this report we describe some of the technical and functional features of this system and illustrate how these features are used in an actual small animal imaging study.
引用
收藏
页码:545 / 548
页数:4
相关论文
共 50 条
  • [41] System Design Considerations for Collimation in a Small-Animal PET Scanner
    Li, Yusheng
    Matej, Samuel
    Karp, Joel S.
    Metzler, Scott D.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2838 - 2842
  • [42] YAP-(S)PET small animal scanner: Quantitative results
    Di Domenico, G
    Zavattini, G
    Moretti, E
    Piffanelli, A
    Giganti, M
    Motta, A
    Sabba, N
    Uccelli, L
    Benini, E
    Duatti, A
    Bolzati, C
    Boschi, A
    Del Guerra, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1351 - 1356
  • [43] Attenuation correction for pre-clinical PET images using a small animal CT scanner
    D'Ambrosio, D.
    Spinelli, A. E.
    Boschi, S.
    Quarta, C.
    Franchi, R.
    Pagotto, U.
    Marengo, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S227 - S228
  • [44] Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    Seidel, J
    Vaquero, JJ
    Green, MV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1347 - 1350
  • [45] Development of a data acquisition system for the MiCES small animal PET scanner
    Lewellen, TK
    Laymon, CM
    Miyaoka, RS
    Janes, M
    Park, B
    Lee, K
    Kinahan, PE
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1066 - 1070
  • [46] Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: Comparison to simulated LSO scanners without depth-of-interaction capability
    Seidel, Y
    Vaquero, JJ
    Green, MV
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1555 - 1558
  • [47] Improving the quantitative accuracy of a dedicated small animal SPECT/CT scanner
    Hwang, A
    Taylor, C
    Seo, Y
    Iwata, K
    Li, J
    Patt, B
    Hasegawa, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2133 - 2134
  • [48] PIXSCAN: Pixel detector CT-scanner for small animal imaging
    Delpierre, P.
    Debarbieux, F.
    Basolo, S.
    Berar, J. F.
    Bonissent, A.
    Boudet, N.
    Breugnon, P.
    Caillot, B.
    Brunner, F. Cassol
    Chantepie, B.
    Clemens, J. C.
    Dinkespiler, B.
    Khouri, R.
    Koudobine, I.
    Mararazzo, V.
    Meessen, C.
    Menouni, M.
    Morel, C.
    Mouget, C.
    Pangaud, P.
    Peyrin, F.
    Rougon, G.
    Sappey-Marinier, D.
    Valton, S.
    Vigeolas, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) : 425 - 428
  • [49] Influence of Co-57 and CT Transmission Measurements on the Quantification Accuracy and Partial Volume Effect of a Small Animal PET Scanner
    Mannheim, Julia G.
    Schmid, Andreas M.
    Pichler, Bernd J.
    MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (06) : 825 - 836
  • [50] Simultaneous PET/SPECT imaging with the small animal scanner YAP-(S)PET
    Bartoli, Antonietta
    Belcari, Nicola
    Del Guerra, Alberto
    Fabbri, Serena
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3408 - 3413