Features of the NIH atlas small animal PET scanner and its use with a coaxial small animal volume CT scanner

被引:0
|
作者
Seidel, J [1 ]
Vaquero, JJ [1 ]
Pascau, J [1 ]
Desco, M [1 ]
Johnson, CA [1 ]
Green, MV [1 ]
机构
[1] NIH, Bethesda, MD 20892 USA
来源
2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS | 2002年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
ATLAS (Advanced Technology Laboratory Animal Scanner), a small animal PET scanner designed to image animals the size of rats and mice, is about to enter service on the NIH campus in Bethesda, Maryland. This system is the first small animal PET scanner with a depth-of-interaction capability and the first to use iterative resolution recovery algorithms, rather than conventional filtered back projection, for "production" image reconstruction. ATLAS is also proximate to, and co-axial with, a high, resolution small animal CT scanner. When fully integrated, spatially registered PET and CT images of each animal will be used to correct the emission data for radiation attenuation and to aid in target identification. In this report we describe some of the technical and functional features of this system and illustrate how these features are used in an actual small animal imaging study.
引用
收藏
页码:545 / 548
页数:4
相关论文
共 50 条
  • [31] A small animal helical SPECT scanner
    Sun, Mingshan
    Izaguirre, Enrique W.
    Funk, Tobias
    Hwang, Andrew B.
    Carver, James
    Thompson, Steve
    Patt, Bradley E.
    Parnham, Kevin B.
    Vandehei, Thor
    Li, Junqiang
    Hasegawa, Bruce H.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2066 - 2069
  • [32] The MediSPECT Small Animal CdTe Scanner
    Montesi, M. C.
    Mettivier, G.
    Curion, A. S.
    Lauria, A.
    Russo, P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 566 - 568
  • [33] PIXSCAN: Pixel detector CT scanner for small animal imaging
    Delpierre, P.
    Basolo, S.
    Berar, J. F.
    Bonissent, A.
    Breugnon, P.
    Boudet, N.
    Caillot, B.
    Clemens, J. C.
    Debarbieux, F.
    Dinkespiler, B.
    Khouri, R.
    Koudobine, I.
    Matarazzo, V.
    Meessen, C.
    Menouni, M.
    Morel, C.
    Mouget, C.
    Pangaud, P.
    Peyrin, F.
    Rougon, G.
    Sappey-Marinier, D.
    Valton, S.
    Vigeolas, E.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2381 - 2385
  • [34] A single slice rebinning/2D exact positioning OSEM reconstruction for the NIH ATLAS small animal PET scanner.
    Liow, J
    Seidel, J
    Johnson, CA
    Toyama, H
    Green, MV
    Innis, RB
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 163P - 163P
  • [35] A high spatial resolution CT scanner for small animal imaging
    Cicalini, E
    Baldazzi, G
    Belcari, N
    Del Guerra, A
    Gombia, M
    Motta, A
    Panetta, D
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 : 313 - 316
  • [36] Characterization of a novel dual-panel PET scanner for use in small animal imaging
    Souris, JS
    Cho, S
    Penney, BC
    Chen, CT
    Kao, CM
    MEDICAL PHYSICS, 2005, 32 (06) : 2133 - 2133
  • [37] The data acquisition system of ClearPET neuro - a small animal PET scanner
    Streun, M
    Brandenburg, G
    Larue, H
    Parl, C
    Ziemons, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 700 - 703
  • [38] Evaluation of the First Silicon Photomultiplier Matrices for a Small Animal PET Scanner
    Llosa, Gabriela
    Belcari, Nicola
    Bisogni, M. Giuseppina
    Collazuol, Gianmaria
    Del Guerra, Alberto
    Marcatili, Sara
    Barrillon, Pierre
    de la Taille, Christophe
    Bondil-Blin, Sylvie
    Dinu, Nicoleta
    Melchiorri, Mirko
    Tarolli, Alessandro
    Piemonte, Claudio
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2849 - +
  • [39] System Design Considerations for Collimation in a Small-Animal PET Scanner
    Li, Yusheng
    Matej, Samuel
    Karp, Joel S.
    Metzler, Scott D.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2838 - 2842
  • [40] Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner
    Visser, Eric P.
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Gotthardt, Martin
    Oyen, Wim J. G.
    Boerman, Otto C.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 139 - 147