Simultaneous Measurement of Pressure and Temperature in Seawater with PDMS Sealed Microfiber Mach-Zehnder Interferometer

被引:74
|
作者
Hou, Yun-Fei [1 ]
Wang, Jing [1 ]
Wang, Xin [1 ]
Liao, Yi-Peng [1 ]
Yang, Lei [1 ]
Cai, En-Lin [2 ]
Wang, Shan-Shan [1 ]
机构
[1] Ocean Univ China, Opt & Optoelect Lab, Dept Phys, Qingdao 266100, Peoples R China
[2] Qingdao Univ, Sch Elect & Informat, Qingdao 266071, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Temperature measurement; Temperature sensors; Optical fiber sensors; Sensitivity; Ocean temperature; Optical fiber polarization; Partial discharges; Pressure sensing; temperature sensing; Mach-Zehnder interferometer; polydimethylsiloxane (PDMS); PHOTONIC CRYSTAL FIBER; REFRACTIVE-INDEX; GAS-PRESSURE; SENSOR; POINT; CAVITY;
D O I
10.1109/JLT.2020.3012716
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Simultaneousmeasurement of pressure and temperature in seawater is realized based on polydimethylsiloxane (PDMS) sealed microfiber Mach-Zehnder interferometer (MZI). Benefitting from the high thermal-optic coefficient and large elasticity of PDMS, high sensitivity and robust structure can be obtained. In theoretical modeling, significant enhanced pressure response in fiber is observed clearly, and pressure or temperature sensitivities are calculated theoretically. In experiment, PDMS sealed MZI is fabricated by a two-step sealing method. Using thisMZI, sensitivity of 13.31 nm/MPa for pressure sensing and -7.41 nm/degrees C for temperature sensing are demonstrated, respectively, which are about one order higher than bare fiber MZIs (without PDMS sealing). To verify the accuracy of sensor, several tests under arbitrarily pressure and temperature are performed with average errors of 4.38% and 1.44%, respectively. In addition, effects of encapsulation on avoiding cross-sensitivity with salinity, PDMS thickness on pressure sensitivity, response time, repeatability, time stability, and polarization of the sensor are also evaluated by experiment. Sensors demonstrated here showadvantages of lowcost, simple fabrication, robust and compact structure, high-pressure resistance, high sensitivity, good repeatability, and long-term stability.
引用
收藏
页码:6412 / 6421
页数:10
相关论文
共 50 条
  • [41] Current sensor based on inline microfiber Mach-Zehnder interferometer
    Jasim, A. A.
    Harun, S. W.
    Muhammad, M. Z.
    Arof, H.
    Ahmad, H.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 192 : 9 - 12
  • [42] All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index
    曹晔
    赵晨
    童峥嵘
    OptoelectronicsLetters, 2015, 11 (06) : 438 - 443
  • [43] Enhancement of temperature sensitivity of a Mach-Zehnder interferometer based on a polymer-overlaid microfiber
    Yoon, Min-Seok
    Kim, Yoen Jun
    Kim, Soo Kyung
    Han, Young-Geun
    24TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2015, 9634
  • [44] All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index
    Cao Y.
    Zhao C.
    Tong Z.-R.
    Optoelectronics Letters, 2015, 11 (06) : 438 - 443
  • [45] Simultaneous measurement of refractive index and temperature using thinned fiber based Mach-Zehnder interferometer
    Li, Lecheng
    Li, Xia
    Xie, Zhenhai
    Liao, Zhaolong
    Tu, Feng
    Liu, Deming
    OPTICS COMMUNICATIONS, 2012, 285 (19) : 3945 - 3949
  • [46] Simultaneous Curvature and Temperature Sensing Based on a Novel Mach-Zehnder Interferometer
    Xiaoyan Sun
    Haifeng Du
    Xinran Dong
    Youwang Hu
    Ji’an Duan
    Photonic Sensors, 2020, 10 : 171 - 180
  • [47] Simultaneous Curvature and Temperature Sensing Based on a Novel Mach-Zehnder Interferometer
    Sun, Xiaoyan
    Du, Haifeng
    Dong, Xinran
    Hu, Youwang
    Duan, Ji'an
    PHOTONIC SENSORS, 2020, 10 (02) : 171 - 180
  • [48] Simultaneous measurement of displacement and temperature using a PMF-based dual Mach-Zehnder interferometer
    Tian, Shuaifei
    Chen, Wenjing
    Li, Hanyang
    Yu, Zhangjun
    Yang, Jun
    Zhang, Yibo
    Zhu, Haibo
    Yuan, Yonggui
    Peng, Feng
    Zhang, Xiaojun
    Jiang, Fuqiang
    Yuan, Libo
    APPLIED OPTICS, 2018, 57 (32) : 9683 - 9689
  • [49] Research on simultaneous temperature and relative humidity measurement based on tapered PCF Mach-Zehnder interferometer
    Zhang, Jietong
    Tong, Zhengrong
    Zhang, Weihua
    Zhao, Yeming
    Li, Jiaxin
    OPTICAL FIBER TECHNOLOGY, 2021, 61
  • [50] Simultaneous measurement of temperature and microdisplacement based on a Mach-Zehnder interferometer cascaded with a fiber Bragg grating
    Cao, Ye
    Liu, Huiying
    Tong, Zhengrong
    Yuan, Shuo
    OPTICAL ENGINEERING, 2015, 54 (06)