Simultaneous Measurement of Pressure and Temperature in Seawater with PDMS Sealed Microfiber Mach-Zehnder Interferometer

被引:74
|
作者
Hou, Yun-Fei [1 ]
Wang, Jing [1 ]
Wang, Xin [1 ]
Liao, Yi-Peng [1 ]
Yang, Lei [1 ]
Cai, En-Lin [2 ]
Wang, Shan-Shan [1 ]
机构
[1] Ocean Univ China, Opt & Optoelect Lab, Dept Phys, Qingdao 266100, Peoples R China
[2] Qingdao Univ, Sch Elect & Informat, Qingdao 266071, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Temperature measurement; Temperature sensors; Optical fiber sensors; Sensitivity; Ocean temperature; Optical fiber polarization; Partial discharges; Pressure sensing; temperature sensing; Mach-Zehnder interferometer; polydimethylsiloxane (PDMS); PHOTONIC CRYSTAL FIBER; REFRACTIVE-INDEX; GAS-PRESSURE; SENSOR; POINT; CAVITY;
D O I
10.1109/JLT.2020.3012716
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Simultaneousmeasurement of pressure and temperature in seawater is realized based on polydimethylsiloxane (PDMS) sealed microfiber Mach-Zehnder interferometer (MZI). Benefitting from the high thermal-optic coefficient and large elasticity of PDMS, high sensitivity and robust structure can be obtained. In theoretical modeling, significant enhanced pressure response in fiber is observed clearly, and pressure or temperature sensitivities are calculated theoretically. In experiment, PDMS sealed MZI is fabricated by a two-step sealing method. Using thisMZI, sensitivity of 13.31 nm/MPa for pressure sensing and -7.41 nm/degrees C for temperature sensing are demonstrated, respectively, which are about one order higher than bare fiber MZIs (without PDMS sealing). To verify the accuracy of sensor, several tests under arbitrarily pressure and temperature are performed with average errors of 4.38% and 1.44%, respectively. In addition, effects of encapsulation on avoiding cross-sensitivity with salinity, PDMS thickness on pressure sensitivity, response time, repeatability, time stability, and polarization of the sensor are also evaluated by experiment. Sensors demonstrated here showadvantages of lowcost, simple fabrication, robust and compact structure, high-pressure resistance, high sensitivity, good repeatability, and long-term stability.
引用
收藏
页码:6412 / 6421
页数:10
相关论文
共 50 条
  • [31] Study of fiber sensor for the simultaneous measurement of temperature and strain based on Mach-Zehnder interferometer
    Bian, Ji-Cheng
    Lang, Ting-Ting
    Yu, Wen-Jie
    Kong, Wen
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (11): : 2169 - 2174
  • [32] Up-taper-based Mach-Zehnder interferometer for temperature and strain simultaneous measurement
    Kang, Zexin
    Wen, Xiaodong
    Li, Chao
    Sun, Jiang
    Wang, Jing
    Jian, Shuisheng
    APPLIED OPTICS, 2014, 53 (12) : 2691 - 2695
  • [33] Ring resonator and Mach-Zehnder interferometer based on PDMS
    Jandura, Daniel
    Pudis, Dusan
    Gaso, Peter
    Durisova, Jana
    Kuzma, Anton
    2016 PHOTONICS NORTH (PN), 2016,
  • [34] Simultaneous measurement of temperature and relative humidity by compact Mach-Zehnder interferometer and Fabry-Perot interferometer
    Tong, Rui-jie
    Zhao, Yong
    Zheng, Hong-kun
    Xia, Feng
    MEASUREMENT, 2020, 155
  • [35] Ultrasensitive Measurement of Micronewton Force or Weak Dynamic Signal Based on PDMS Sealed Tapered Fiber Mach-Zehnder Interferometer
    Xu, Tianzong
    Li, Lijun
    Xue, Mengge
    Yang, Fan
    Wang, Jie
    Wen, Zhijie
    Ma, Qian
    IEEE SENSORS JOURNAL, 2024, 24 (05) : 6240 - 6250
  • [36] A Hybrid Mach-Zehnder Interferometer for Refractive Index and Temperature Measurement
    Ni, Xiaoqi
    Wang, Ming
    Guo, Dongmei
    Hao, Hui
    Zhu, Jiali
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (17) : 1850 - 1853
  • [37] Microfiber Mach-Zehnder interferometer embedded in low index polymer
    Sulaiman, A.
    Harun, S. W.
    Lim, K. S.
    Ahmad, F.
    Ahmad, H.
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (04): : 1186 - 1189
  • [38] A Thermally Annealed Mach-Zehnder Interferometer for High Temperature Measurement
    Feng, Zhongyao
    Li, Jiacheng
    Qiao, Xueguang
    Li, Ling
    Yang, Hangzhou
    Hu, Manli
    SENSORS, 2014, 14 (08): : 14210 - 14221
  • [39] Microfiber in-line Mach-Zehnder interferometer for strain sensing
    Liao, C. R.
    Wang, D. N.
    Wang, Ying
    OPTICS LETTERS, 2013, 38 (05) : 757 - 759
  • [40] Microfiber-Based Inline Mach-Zehnder Interferometer for Dual-Parameter Measurement
    Luo, Haipeng
    Sun, Qizhen
    Xu, Zhilin
    Jia, Weihua
    Liu, Deming
    Zhang, Lin
    IEEE PHOTONICS JOURNAL, 2015, 7 (02):