Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography-influence of image reconstruction interval on graft visibility

被引:22
作者
Willmann, JK
Weishaupt, D
Kobza, R
Verdun, FR
Seifert, B
Marincek, B
Boehm, T
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Clin Cardiol, CH-8091 Zurich, Switzerland
[3] Univ Lausanne, Inst Appl Radiophys, Lausanne, Switzerland
[4] Univ Zurich, Dept Biostat, Zurich, Switzerland
关键词
arteries; grafts and prostheses; computed tomography (CT); angiography; multidetector row; coronary angiography; coronary vessels; bypass graft;
D O I
10.1148/radiol.2322030788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS: Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-detector row CT angiography and conventional coronary angiography. Raw helical CT data were reconstructed at 0%-90% of the cardiac cycle in increments of 10%. Each graft was separated into three segments (proximal segment, graft body, and distal anastomosis). Three graft types were identified according to site of distal anastomosis. Two readers assessed image quality of segments and graft types. Effective radiation dose was calculated. RESULTS: Best image quality of all segments was obtained at a reconstruction interval of 500/6-70% of the cardiac cycle. Image quality of the proximal segment did not vary significantly with different reconstruction intervals (analysis of variance, P = .8), whereas image quality of the graft body and clistal anastomosis changed significantly with varying reconstruction intervals (P < .001). Distal anastomosis and body of types 1 and 2 grafts were best seen at 60%-70% of the cardiac cycle, whereas distal anastomosis and body of type 3 grafts were best visualized at 50%. Accuracy of CT angiography for detection of graft patency was 94% for reader I and 95% for reader 2. Effective dose for CT was 11.4 mSv for both men and women. Mean effective dose for angiography was 2.1 mSv for men and women. CONCLUSION: Optimal selection of reconstruction interval improves image quality of the graft body and of distal anastomosis in particular. (C) RSNA, 2004.
引用
收藏
页码:568 / 577
页数:10
相关论文
共 24 条
[1]   Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Bachmann, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) :856-861
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[4]   Calibration of ionization chambers in air kerma length [J].
Bochud, FO ;
Grecescu, M ;
Valley, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09) :2477-2487
[5]  
BOURASSA MG, 1985, CIRCULATION, V72, P71
[6]  
CAMPEAU L, 1983, CIRCULATION, V68, P1
[7]   Accuracy of spiral computed tomography for identifying arterial and venous coronary graft patency [J].
Engelmann, MG ;
vonSmekal, A ;
Knez, A ;
Kurzinger, E ;
Huehns, TY ;
Hofling, B ;
Reiser, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (05) :569-574
[8]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[9]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[10]  
GRONDIN CM, 1989, CIRCULATION, V79, P24