Precise simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples following their successive i.p. administration

被引:6
作者
Nakhla, David S. [1 ,2 ]
Hussein, Lobna A. [3 ]
Magdy, N. [3 ]
Abdallah, Inas A. [1 ,4 ]
Hassan, Hazem E. [1 ,5 ]
机构
[1] Univ Maryland, Sch Pharm, Dept Pharmaceut Sci, 20 N Pine St,Room N525, Baltimore, MD 21201 USA
[2] Misr Int Univ, Fac Pharm, Dept Pharmaceut Chem, Cairo, Egypt
[3] Ain Shams Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Cairo, Egypt
[4] Univ Sadat City, Fac Pharm, Dept Analyt Chem, Sadat City, Egypt
[5] Helwan Univ, Fac Pharm, Dept Pharmaceut & Ind Pharm, Cairo, Egypt
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1048卷
关键词
HPLC; Methadone; Cocaine; Rats; Serum; Brain; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; DIODE-ARRAY DETECTION; HUMAN PLASMA; BIOLOGICAL-FLUIDS; DRUG-INTERACTIONS; HUMAN URINE; ORAL FLUID; LC-MS/MS;
D O I
10.1016/j.jchromb.2017.01.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive high-performance liquid chromatography (HPLC) assay with dual UV detection has been developed and validated for the simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples. Liquid-liquid extraction using hexanes was applied for samples extraction with Levo-Tetrahydropalmatine (L-THP) as the internal standard. Chromatographic separation of the analytes was achieved on a reversed -phase Waters Symmetry((R)) C-18 column (150 mm x 4.6 mm, 5 mu m). A gradient elution was employed with a mobile phase consisting of 5 mM potassium phosphate containing 0.1% triethylamine (pH = 6.5) (A) and acetonitrile (B) with a flow rate of 1 mL/min. UV detection was employed at 215 nm and 235 nm for the determination of methadone and cocaine, respectively. The calibration curves were linear over the range of 0.05-10 mu g/mL for both methadone and cocaine. The assay was validated according to FDA guidelines for bioanalytical method validation and results were satisfactory and met FDA criteria. Inter-day accuracy values of serum and brain samples ranged from 96.97 to 105.59% while intra-day accuracy values ranged from 91.49 to 111.92%. Stability assays showed that both methadone and cocaine were stable during sample storage, preparation, and analytical procedures. The method was successfully used to analyze biological samples obtained from a drug- drug interaction pharmacokinetics (PK) study conducted in rats to investigate the effect of methadone on cocaine PK. Our method not only can be used for bioanalysis of samples obtained from rats but also can potentially be applied to human biological serum samples to monitor compliance to methadone maintenance therapy (MMT) and to detect possible cocaine-methadone co-abuse. (c)2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 57 条
[11]   High-throughput simultaneous analysis of buprenorphine, methadone, cocaine, opiates, nicotine, and metabolites in oral fluid by liquid chromatography tandem mass spectrometry [J].
Concheiro, Marta ;
Gray, Teresa R. ;
Shakleya, Diaa M. ;
Huestis, Marilyn A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) :915-924
[12]   Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid [J].
Dams, R ;
Huestis, MA ;
Lambert, WE ;
Murphy, CM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (11) :1290-1294
[13]   LC-atmospheric pressure chemical ionization-MS/MS analysis of multiple illicit drugs, methadone, and their metabolites in oral fluid following protein precipitation [J].
Dams, R ;
Murphy, CM ;
Choo, RE ;
Lambert, WE ;
De Leenheer, AP ;
Huestis, MA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :798-804
[14]   Oral fluid as an alternative matrix to monitor opiate and cocaine use in substance-abuse treatment patients [J].
Dams, Riet ;
Choo, Robin E. ;
Lambert, Willy E. ;
Jones, Hendree ;
Huestis, Marilyn A. .
DRUG AND ALCOHOL DEPENDENCE, 2007, 87 (2-3) :258-267
[15]   Simultaneous Quantification of Methadone, Cocaine, Opiates, and Metabolites in Human Placenta by Liquid Chromatography-Mass Spectrometry [J].
de Castro, Ana ;
Concheiro, Marta ;
Shakleya, Diaa M. ;
Huestis, Marilyn A. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (05) :243-252
[16]   Determination of free and protein-bound methadone and its major metabolite EDDP: Enantiomeric separation and quantitation by LC/MS/MS [J].
Etter, ML ;
George, S ;
Graybiel, K ;
Eichhorst, J ;
Lehotay, DC .
CLINICAL BIOCHEMISTRY, 2005, 38 (12) :1095-1102
[17]   Analysis of opiates, cocaine and metabolites in urine by high-performance liquid chromatography with diode array detection (HPLC-DAD) [J].
Fernández, P ;
Vázquez, C ;
Morales, L ;
Bermejo, AM .
JOURNAL OF APPLIED TOXICOLOGY, 2005, 25 (03) :200-204
[18]   Microwave-assisted extraction and HPLC-DAD determination of drugs of abuse in human plasma [J].
Fernandez, Purificacion ;
Lago, Marta ;
Lorenzo, Rosa Antonia ;
Carro, Antonia Maria ;
Bermejo, Ana Maria ;
Tabernero, Maria Jesus .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (07) :388-393
[19]   Stereoselective quantification of methadone and its major oxidative metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, in human urine using high-performance liquid chromatography [J].
Foster, DJR ;
Somogyi, AA ;
Bochner, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 744 (01) :165-176
[20]   Determination of free-form of cocaine in rat brain by liquid chromatography-electrospray mass spectrometry with in vivo microdialysis [J].
Fuh, MR ;
Tai, YL ;
Pan, WHT .
JOURNAL OF CHROMATOGRAPHY B, 2001, 752 (01) :107-114