Precise simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples following their successive i.p. administration

被引:6
作者
Nakhla, David S. [1 ,2 ]
Hussein, Lobna A. [3 ]
Magdy, N. [3 ]
Abdallah, Inas A. [1 ,4 ]
Hassan, Hazem E. [1 ,5 ]
机构
[1] Univ Maryland, Sch Pharm, Dept Pharmaceut Sci, 20 N Pine St,Room N525, Baltimore, MD 21201 USA
[2] Misr Int Univ, Fac Pharm, Dept Pharmaceut Chem, Cairo, Egypt
[3] Ain Shams Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Cairo, Egypt
[4] Univ Sadat City, Fac Pharm, Dept Analyt Chem, Sadat City, Egypt
[5] Helwan Univ, Fac Pharm, Dept Pharmaceut & Ind Pharm, Cairo, Egypt
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1048卷
关键词
HPLC; Methadone; Cocaine; Rats; Serum; Brain; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; DIODE-ARRAY DETECTION; HUMAN PLASMA; BIOLOGICAL-FLUIDS; DRUG-INTERACTIONS; HUMAN URINE; ORAL FLUID; LC-MS/MS;
D O I
10.1016/j.jchromb.2017.01.048
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive high-performance liquid chromatography (HPLC) assay with dual UV detection has been developed and validated for the simultaneous quantification of methadone and cocaine in rat serum and brain tissue samples. Liquid-liquid extraction using hexanes was applied for samples extraction with Levo-Tetrahydropalmatine (L-THP) as the internal standard. Chromatographic separation of the analytes was achieved on a reversed -phase Waters Symmetry((R)) C-18 column (150 mm x 4.6 mm, 5 mu m). A gradient elution was employed with a mobile phase consisting of 5 mM potassium phosphate containing 0.1% triethylamine (pH = 6.5) (A) and acetonitrile (B) with a flow rate of 1 mL/min. UV detection was employed at 215 nm and 235 nm for the determination of methadone and cocaine, respectively. The calibration curves were linear over the range of 0.05-10 mu g/mL for both methadone and cocaine. The assay was validated according to FDA guidelines for bioanalytical method validation and results were satisfactory and met FDA criteria. Inter-day accuracy values of serum and brain samples ranged from 96.97 to 105.59% while intra-day accuracy values ranged from 91.49 to 111.92%. Stability assays showed that both methadone and cocaine were stable during sample storage, preparation, and analytical procedures. The method was successfully used to analyze biological samples obtained from a drug- drug interaction pharmacokinetics (PK) study conducted in rats to investigate the effect of methadone on cocaine PK. Our method not only can be used for bioanalysis of samples obtained from rats but also can potentially be applied to human biological serum samples to monitor compliance to methadone maintenance therapy (MMT) and to detect possible cocaine-methadone co-abuse. (c)2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 57 条
[1]  
Abdallah I. A., 2016, BIOMED CHROMATOGR
[2]   A fully validated LC-MS/MS method for simultaneous determination of nicotine and its metabolite cotinine in human serum and its application to a pharmacokinetic study after using nicotine transdermal delivery systems with standard heat application in adult smokers [J].
Abdallah, Inas A. ;
Hammell, Dana C. ;
Stinchcomb, Audra L. ;
Hassan, Hazem E. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1020 :67-77
[3]   Enantioselective high-performance liquid chromatographic method for the determination of methadone and its main metabolite in urine using an AGP and a C8 column coupled serially [J].
Angelo, HR ;
Beck, N ;
Kristensen, K .
JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (01) :35-40
[4]   THE EFFECT OF INCREASED COCAINE USE ON DRUG-TREATMENT [J].
BLACK, JL ;
DOLAN, MP ;
PENK, WE ;
ROBINOWITZ, R ;
DEFORD, HA .
ADDICTIVE BEHAVIORS, 1987, 12 (03) :289-292
[5]  
Boulton DW, 2000, CHIRALITY, V12, P681, DOI 10.1002/1520-636X(2000)12:9<681::AID-CHIR7>3.0.CO
[6]  
2-J
[7]   Determination of basic drugs of abuse in human serum by online extraction and LC-MS/MS [J].
Bouzas, Nerea Ferreiros ;
Dresen, Sebastian ;
Munz, Barbara ;
Weinmann, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (08) :2499-2507
[8]   Structure-activity relationships for thiol reactivity and rat or human hepatocyte toxicity induced by substituted p-benzoquinone compounds [J].
Chan, Katie ;
Jensen, Neil ;
O'Brien, Peter J. .
JOURNAL OF APPLIED TOXICOLOGY, 2008, 28 (05) :608-620
[9]   Novel high-performance liquid chromatographic and solid-phase extraction methods for quantitating methadone and its metabolite in spiked human urine [J].
Cheng, YF ;
Neue, UD ;
Woods, LL .
JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2) :19-31
[10]   Simultaneous analysis of buprenorphine, methadone, cocaine, opiates and nicotine metabolites in sweat by liquid chromatography tandem mass spectrometry [J].
Concheiro, Marta ;
Shakleya, Diaa M. ;
Huestis, Marilyn A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) :69-78