Intraoperative near-infrared imaging of parathyroid glands: A comparison of first- and second-generation technologies

被引:13
|
作者
Akbulut, Serkan [1 ]
Erten, Ozgun [1 ]
Gokceimam, Mehmet [1 ]
Kim, Yoo S. [1 ]
Krishnamurthy, Vikram [1 ]
Heiden, Katherine [1 ]
Jin, Judy [1 ]
Siperstein, Allan [1 ]
Berber, Eren [1 ,2 ]
机构
[1] Cleveland Clin, Dept Endocrine, 9500 Euclid Ave,F20, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Gen Surg, Cleveland, OH 44195 USA
关键词
autofluorescence; near‐ infrared fluorescence imaging; parathyroid gland; IDENTIFICATION; THYROIDECTOMY; FLUORESCENCE; SPECTROSCOPY;
D O I
10.1002/jso.26336
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Intraoperative near-infrared imaging (NIFI) of parathyroid glands (PG) by first-generation technology had limited image quality and depth penetration. Second-generation NIFI has recently been introduced. Our aim was to compare (1) capability to detect PG and (2) image quality between older and newer technologies. Methods Accurately detecting PG, as well as, quality of autofluorescence (AF) was compared between an older charge-coupled device (CCD) camera and a newer complementary metal-oxide semiconductor (CMOS). chi(2), t test, and analysis of variance were used for analysis. Results There were 300 patients who underwent parathyroidectomy (PTX) and/or thyroidectomy (THY) with NIFI, 200 with CCD, and 100 with CMOS. Although both NIFI technologies detected >94% of PG, CMOS was superior to CCD. Comparing AF quality, mean pixel intensity of PG compared with the background was higher with CMOS compared with CCD. When comparing PG detected by NIFI before visual identification by a surgeon, both CCD and CMOS had similar results (25% vs. 22%; p = .3). Conclusion Both NIFI cameras were excellent at detecting PG. Second-generation NIFI (CMOS) displayed higher detection rates and AF intensity. Although surgeons identified majority of PG before NIFI detection, 25% of PG were identified with NIFI first, suggesting future advancements of this technology may expand its applications during parathyroid/thyroid operations.
引用
收藏
页码:866 / 871
页数:6
相关论文
共 50 条
  • [21] Near-infrared autofluorescence-based parathyroid glands identification in the thyroidectomy or parathyroidectomy: a systematic review and meta-analysis
    Kim, Do Hyun
    Lee, Sunwoo
    Jung, Jaehoon
    Kim, Sohyun
    Kim, Sung Won
    Hwang, Se Hwan
    LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (02) : 491 - 499
  • [22] Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs
    Suh, Yong Joon
    Choi, June Young
    Chai, Young Jun
    Kwon, Hyungju
    Woo, Jung-Woo
    Kim, Su-jin
    Kim, Kyu Hyung
    Lee, Kyu Eun
    Lim, Yong Taik
    Youn, Yeo-Kyu
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (09): : 2811 - 2817
  • [23] Intraoperative Near-infrared Imaging for Parathyroid Gland Identification by Auto-fluorescence: A Feasibility Study
    Frederic De Leeuw
    Ingrid Breuskin
    Muriel Abbaci
    Odile Casiraghi
    Haïtham Mirghani
    Aïcha Ben Lakhdar
    Corinne Laplace-Builhé
    Dana Hartl
    World Journal of Surgery, 2016, 40 : 2131 - 2138
  • [24] Near infrared fluorescence imaging of rabbit thyroid and parathyroid glands
    Antakia, Ramez
    Gayet, Pascal
    Guillermet, Stephanie
    Stephenson, Tim J.
    Brown, Nicola J.
    Harrison, Barney J.
    Balasubramanian, Saba P.
    JOURNAL OF SURGICAL RESEARCH, 2014, 192 (02) : 480 - 486
  • [25] Why does diseased parathyroid appear weak or heterogenous intensity during intraoperative near-infrared autofluorescence?
    Huang, Shih-Ming
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [26] Optimization of Second Window Indocyanine Green for Intraoperative Near-Infrared Imaging of Thoracic Malignancy
    Newton, Andrew D.
    Predina, Jarrod D.
    Corbett, Christopher J.
    Frenzel-Sulyok, Lydia G.
    Xia, Leilei
    Petersson, E. James
    Tsourkas, Andrew
    Nie, Shuming
    Delikatny, Edward J.
    Singhal, Sunil
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2019, 228 (02) : 188 - 197
  • [27] Intraoperative near-infrared fluorescence imaging of parathyroid adenomas with use of low-dose methylene blue
    van der Vorst, Joost R.
    Schaafsma, Boudewijn E.
    Verbeek, Floris P. R.
    Swijnenburg, Rutger-Jan
    Tummers, Quirijn R. J. G.
    Hutteman, Merlijn
    Hamming, Jaap F.
    Kievit, Job
    Frangioni, John V.
    van de Velde, Cornelis J. H.
    Vahrmeijer, Alexander L.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (06): : 853 - 858
  • [28] Intraoperative real-time localization of parathyroid gland with near infrared fluorescence imaging
    Kim, Sung Won
    Lee, Hyoung Shin
    Lee, Kang Dae
    GLAND SURGERY, 2017, 6 (05) : 516 - 524
  • [29] Intraoperative guidance in parathyroid surgery using near-infrared fluorescence imaging and low-dose Methylene Blue
    Tummers, Quirijn R. J. G.
    Schepers, Abbey
    Hamming, Jaap F.
    Kievit, J.
    Frangioni, John V.
    van de Velde, Cornelis J. H.
    Vahrmeijer, Alexander L.
    SURGERY, 2015, 158 (05) : 1323 - 1330
  • [30] Intraoperative near-infrared fluorescent imaging during robotic operations
    de Vasconcellos Macedo, Antonio Luiz
    Schraibman, Vladimir
    Einstein-Sao Paulo, 2016, 14 (04): : 577 - 579