The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files

被引:8
|
作者
Ruiz-Sanchez, Celia [1 ]
Faus-Llacer, Vicente [1 ]
Faus-Matoses, Ignacio [1 ]
Zubizarreta-Macho, Alvaro [2 ]
Sauro, Salvatore [3 ,4 ]
Faus-Matoses, Vicente [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Stomatol, Valencia 46010, Spain
[2] Alfonso X El Sabio Univ, Fac Hlth Sci, Dept Endodont, Madrid 28691, Spain
[3] CEU Cardenal Herrera Univ, Fac Hlth Sci, Dept Dent, Valencia 46115, Spain
[4] IM Sechenov First Moscow State Med Univ, Dept Therapeut Dent, Moscow 119146, Russia
关键词
endodontics; cyclic fatigue; NiTi alloy; M-Wire; CM-Gold Wire; CM-Blue Wire; PROTAPER UNIVERSAL INSTRUMENTS; TITANIUM ROTARY INSTRUMENTS; MECHANICAL-PROPERTIES; RECIPROC BLUE; WAVEONE GOLD; PERFORMANCE; CURVATURE; FRACTURE; SAFETY; IMPACT;
D O I
10.3390/jcm9113755
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 mu m apical diameter, 60 degrees curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
引用
收藏
页码:1 / 15
页数:16
相关论文
共 50 条
  • [41] Improving the reliability of NiTi endodontic files using eddy currents, thermography and fatigue tests: A multimethod approach
    Alves, Elisa
    Saldanha, Guilherme
    Machado, Miguel A.
    Santos, Telmo G.
    Martins, Rui F.
    INTERNATIONAL JOURNAL OF FATIGUE, 2023, 177
  • [42] The effects of shape memory alloys' tension-compression asymmetryon NiTi endodontic files' fatigue life
    Karamooz-Ravari, M. R.
    Dehghani, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (05) : 437 - 445
  • [43] Dynamic or static cyclic fatigue tests: which best determines the lifespan of endodontic files?
    Gambarra-Soares, Thaiane
    Lopes, Helio Pereira
    Machado Oliveira, Julio Cezar
    Souza, Leticia Chaves
    Leal Vieira, Victor Talarico
    Elias, Carlos Nelson
    ENDO-ENDODONTIC PRACTICE TODAY, 2013, 7 (02): : 101 - 104
  • [44] Fatigue resistance of NiTi rotary files operated with low-torque motor
    Gambarini, G
    Laszkiewicz, J
    Piatowska, D
    Bossu, M
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1288 - 1288
  • [45] Cyclic Fatigue and Torsional Failure of EdgeTaper Platinum Endodontic Files at Simulated Body Temperature
    Jamleh, Ahmed
    Alghaihab, Amjad
    Alfadley, Abdulmohsen
    Alfawaz, Hussam
    Alqedairi, Abdullah
    Alfouzan, Khalid
    JOURNAL OF ENDODONTICS, 2019, 45 (05) : 611 - 614
  • [46] Fatigue Analysis of NiTi Rotary Endodontic Files through Finite Element Simulation: Effect of Root Canal Geometry on Fatigue Life
    Roda-Casanova, Victor
    Perez-Gonzalez, Antonio
    Zubizarreta-Macho, Alvaro
    Faus-Matoses, Vicente
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (23)
  • [47] XRD Study of NiTi Endodontic Files Using Synchrotron Radiation
    Francisco Manuel Braz Fernandes
    J. P. Oliveira
    A. Machado
    Norbert Schell
    Journal of Materials Engineering and Performance, 2014, 23 : 2477 - 2481
  • [48] Influence of different heat treatments and temperatures on the cyclic fatigue resistance of endodontic instruments with the same design
    Walid Nehme
    Alfred Naaman
    Franck Diemer
    Maria Laura Leotta
    Giusy Rita Maria La Rosa
    Eugenio Pedullà
    Clinical Oral Investigations, 2023, 27 : 1793 - 1798
  • [49] Influence of different heat treatments and temperatures on the cyclic fatigue resistance of endodontic instruments with the same design
    Nehme, Walid
    Naaman, Alfred
    Diemer, Franck
    Leotta, Maria Laura
    La Rosa, Giusy Rita Maria
    Pedulla, Eugenio
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (04) : 1793 - 1798
  • [50] Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of V taper 2 and V taper 2H rotary NiTi files
    Chang, S. W.
    Shim, K. S.
    Kim, Y. C.
    Jee, K. K.
    Zhu, Q.
    Perinpanayagam, H.
    Kum, K. Y.
    SCANNING, 2016, 38 (06) : 564 - 570