Highly Efficient Motion-Corrected Simultaneous Cardiac PET-MR Imaging

被引:0
作者
Munoz, Camila [1 ]
Neji, Radhouene [1 ,2 ]
Marsden, Paul [1 ]
Reader, Andrew J. [1 ]
Botnar, Rene M. [1 ]
Prieto, Claudia [1 ]
机构
[1] Kings Coll London, Dept Biomed Engn, Div Imaging Sci & Biomed Engn, London, England
[2] Siemens Healthcare, MR Res Collaborat, Frimley, England
来源
2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD) | 2016年
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
MR-based motion correction of PET data has been proposed as a high-impact application for improving image quality and myocardial tissue quantification in cardiac PET-MR imaging. However, current PET-MR motion compensation schemes acquire only motion information from MR data during PET acquisition time and diagnostic MR images afterwards, significantly increasing total exam time. Here we propose an efficient acquisition and reconstruction scheme for simultaneous cardiac PET-MR imaging that acquires both diagnostic and motion information from MR, with motion information being used to correct both PET and MR data. The proposed MR acquisition scheme includes acquiring low-resolution 2D image navigators at each heartbeat by spatially encoding the start-up echoes of an ECG-gated gradient echo sequence, allowing for 100% MR scan efficiency (i.e. all data is accepted for reconstruction, reducing scan time). These 2D image navigators are then used to estimate foot-head and right-left motion of the heart during the respiratory cycle in a beat-to-beat fashion, providing motion estimates to translationally correct and bin the MR data. MR images from each respiratory bin are used to estimate 3D non-rigid motion between respiratory bins. These non-rigid motion fields are then used for correcting both the MR and PET data. Results from healthy volunteers show that motion correction improves MR visualisation of the right and left anterior descending coronary arteries. A simulated PET acquisition showed improvements in contrast of the myocardium and better depiction of papillary muscles when applying motion correction. The presented framework improves image quality and contrast compared with uncorrected images for both MR and PET images.
引用
收藏
页数:3
相关论文
共 9 条
[1]   Matrix description of general motion correction applied to multishot images [J].
Batchelor, PG ;
Atkinson, D ;
Irarrazaval, P ;
Hill, DLG ;
Hajnal, J ;
Larkman, D .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1273-1280
[2]   Whole-heart coronary MR angiography with 2D self-navigated image reconstruction [J].
Henningsson, Markus ;
Koken, Peter ;
Stehning, Christian ;
Razavi, Reza ;
Prieto, Claudia ;
Botnar, Rene M. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) :437-445
[3]   MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging [J].
Munoz, Camila ;
Kolbitsch, Christoph ;
Reader, Andrew J. ;
Marsden, Paul ;
Schaeffter, Tobias ;
Prieto, Claudia .
PET CLINICS, 2016, 11 (02) :179-191
[4]   Towards coronary plaque imaging using simultaneous PET-MR: a simulation study [J].
Petibon, Y. ;
El Fakhri, G. ;
Nezafat, R. ;
Johnson, N. ;
Brady, T. ;
Ouyang, J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) :1203-1222
[5]   Highly Efficient Respiratory Motion Compensated Free-Breathing Coronary MRA Using Golden-Step Cartesian Acquisition [J].
Prieto, Claudia ;
Doneva, Mariya ;
Usman, Muhammad ;
Henningsson, Markus ;
Greil, Gerald ;
Schaeffter, Tobias ;
Botnar, Rene M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) :738-746
[6]   Hybrid PET/MR Imaging of the Heart: Potential, Initial Experiences, and Future Prospects [J].
Rischpler, Christoph ;
Nekolla, Stephan G. ;
Dregely, Isabel ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (03) :402-415
[7]   STIR: software for tomographic image reconstruction release 2 [J].
Thielemans, Kris ;
Tsoumpas, Charalampos ;
Mustafovic, Sanida ;
Beisel, Tobias ;
Aguiar, Pablo ;
Dikaios, Nikolaos ;
Jacobson, Matthew W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (04) :867-883
[8]   Fast generation of 4D PET-MR data from real dynamic MR acquisitions [J].
Tsoumpas, C. ;
Buerger, C. ;
King, A. P. ;
Mollet, P. ;
Keereman, V. ;
Vandenberghe, S. ;
Schulz, V. ;
Schleyer, P. ;
Schaeffter, T. ;
Marsden, P. K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20) :6597-6613
[9]   Standardized uptake value atlas:: Characterization of physiological 2-deoxy-2-[18F]fluoro-D-glucose uptake in normal tissues [J].
Wang, Yingbing ;
Chiu, Edison ;
Rosenberg, Jarrett ;
Gambhir, Sanjiv Sam .
MOLECULAR IMAGING AND BIOLOGY, 2007, 9 (02) :83-90