Determination of 26 polychlorinated biphenyls congeners in soil samples using microwave-assisted extraction with open vessel and gas chromatography

被引:10
作者
Halfadji, Ahmed [1 ,2 ]
Touabet, Abdelkrim [1 ]
机构
[1] USTHB, LAOF, Fac Chem, Algiers, Algeria
[2] Univ Ibn Khaldoun Tiaret, Fac Sci Appl, Dept Sci & Technol, Tiaret, Algeria
关键词
Microwave-assisted extraction in open vessel (MAE-OV); Soxhlet method; polychlorinated biphenyls; soil analysis; gas chromatography (GC-ECD); POLYCYCLIC AROMATIC-HYDROCARBONS; ACCELERATED SOLVENT-EXTRACTION; POLYBROMINATED DIPHENYL ETHERS; SOXHLET EXTRACTION; ORGANIC-COMPOUNDS; FLUID EXTRACTION; SEDIMENTS; EFFICIENCY;
D O I
10.1080/17518253.2018.1445300
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A procedure focused on microwave-assisted extraction in open vessel (MAE-OV) and gas chromatography with electron capture detection (GC-ECD) was used for the determination of 26 congeners of polychlorinated biphenyls (PCBs) in soil samples. The limit of detection (LOD) and limit of quantification (LOQ) were evaluated for commercial PCBs mixture Aroclor1260. LOD and LOQ were calculated for each PCB congener, in the ranges (0.03-0.27ngg(-1)) and (0.11-0.70ngg(-1)), respectively. After optimization, 26 PCBs congeners were successfully extracted from soil samples with recovery amounts ranging between 84.7% and 117.3% for all PCBs congeners. The evaluated method of MAE-OV showed good separation and extraction of all PCBs congeners from soil samples. Extraction parameters such as solvent choice, power and extraction time were investigated. This study indicated that MAE-OV could be an interesting alternative method to extract PCBs from soils, since it is economical, easy, fast and requires low amounts of solvents. [GRAPHICS] .
引用
收藏
页码:209 / 216
页数:8
相关论文
共 28 条
  • [1] Ahlborg U.G., 1992, RISK ASSESSMENT POLY
  • [2] Determination of selected polychlorinated biphenyls in soil by miniaturised ultrasonic solvent extraction and gas chromatography-mass-selective detection
    Aydin, Mehmet Emin
    Tor, Ali
    Ozcan, Senar
    [J]. ANALYTICA CHIMICA ACTA, 2006, 577 (02) : 232 - 237
  • [3] Betit C., 2014, COMP MULTIPLE DRUG M
  • [4] Pressurized fluid extraction of polychlorinated biphenyls in solid environmental samples
    Björklund, E
    Bowadt, S
    Nilsson, T
    Mathiasson, L
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (02) : 285 - 293
  • [5] Dedrick R.L., 2012, Polychlorinated biphenyls (PCBs): mammalian and environmental toxicology, V1
  • [6] Eskilsson CS, 2000, J CHROMATOGR A, V902, P227
  • [7] Microwave assisted water extraction of plant compounds
    Florez, Noelia
    Conde, Enma
    Dominguez, Herminia
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (04) : 590 - 607
  • [8] MICROWAVE EXTRACTION - A NOVEL SAMPLE PREPARATION METHOD FOR CHROMATOGRAPHY
    GANZLER, K
    SALGO, A
    VALKO, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 371 : 299 - 306
  • [9] Chemometric study of selected polychlorinated biphenyls in ambient air of Madrid (Spain)
    García-Alonso, S
    Pérez-Pastor, RM
    Quejido-Cabezas, AJ
    [J]. TALANTA, 2002, 57 (04) : 773 - 783
  • [10] RAPID DECHLORINATION OF POLYCHLORINATED-BIPHENYLS ON THE SURFACE OF A PD/FE BIMETALLIC SYSTEM
    GRITTINI, C
    MALCOMSON, M
    FERNANDO, Q
    KORTE, N
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (11) : 2898 - 2900