Dual-Energy CT for the Assessment of Contrast Material Distribution in the Pulmonary Parenchyma

被引:168
作者
Thieme, Sven F. [1 ]
Johnson, Thorsten R. C. [1 ]
Lee, Christopher [2 ]
McWilliams, Justin [3 ]
Becker, Christoph R. [1 ]
Reiser, Maximilian F. [1 ]
Nikolaou, Konstantin [1 ]
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol, Thorac Imaging Sect, Los Angeles, CA 90095 USA
[3] Ronald Reagan UCLA, Dept Intervent Radiol, Med Ctr, Los Angeles, CA USA
关键词
dual-energy CT; iodine distribution maps; pulmonary embolism; pulmonary perfusion; COMPUTED-TOMOGRAPHY; BLOOD-FLOW; PERFUSION; EMBOLISM; HYPERTENSION; DIAGNOSIS; LUNG; ANGIOGRAPHY; EXPERIENCE; SPECT;
D O I
10.2214/AJR.08.1653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the feasibility and diagnostic value of dual-energy CT iodine mapping at pulmonary CT angiography. SUBJECTS AND METHODS. Ninety-three patients underwent CT angiography with the dual-energy technique on a dual-source CT scanner. Postprocessing was used to map iodine in the lung parenchyma on the basis of its spectral behavior, and image quality was assessed by two readers. Iodine distribution patterns were rated as homogeneous, patchy, or circumscribed defects. Conventional CT angiographic images reconstructed from the same data sets were reviewed for the presence and localization of pulmonary embolism, whether embolic occlusion was partial or complete, and the presence of changes in the lung parenchyma. Dual-energy perfusion findings were correlated with the CT angiographic and lung-window CT findings in per-patient and per-segment analyses. RESULTS. Iodine distribution was homogeneous in 49 patients, of whom CT angiography showed no pulmonary embolism in 46 patients and nonocclusive pulmonary emboli in three patients. Images of 29 patients showed a patchy pattern; 24 of these patients had no pulmonary embolism, and five had nonocclusive pulmonary emboli with solely nonocclusive intravascular clots. Images of 15 patients showed segmental or subsegmental defects; four of these patients had evidence of pulmonary embolism, and 11 had occlusive pulmonary emboli with at least one occlusive clot in the pulmonary vasculature. CONCLUSION. Dual-energy CT is reliable in the detection of defects in pulmonary parenchymal iodine distribution that correspond to embolic vessel occlusion.
引用
收藏
页码:144 / 149
页数:6
相关论文
共 24 条
  • [1] Fink C, 2007, RADIOLOGE, V47, P708, DOI 10.1007/s00117-007-1532-6
  • [2] Regional lung perfusion:: Assessment with partially parallel three-dimensional MR imaging
    Fink, C
    Puderbach, M
    Bock, M
    Lodemann, KP
    Zuna, I
    Schmähl, A
    Delorme, S
    Kauczor, HU
    [J]. RADIOLOGY, 2004, 231 (01) : 175 - 184
  • [3] Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging - Intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels
    Fink, C
    Puderbach, M
    Ley, S
    Plathow, C
    Bock, M
    Zuna, I
    Kauczor, HU
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (03) : 143 - 148
  • [4] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [5] When to perform CTA in patients suspected of PE?
    Ghaye, Benoit
    Dondelinger, Robert F.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (03) : 500 - 509
  • [6] Hatabu H, 2000, MAGN RESON MED, V44, P808, DOI 10.1002/1522-2594(200011)44:5<808::AID-MRM20>3.0.CO
  • [7] 2-4
  • [8] Hatabu H, 1999, MAGNET RESON MED, V42, P1033, DOI 10.1002/(SICI)1522-2594(199912)42:6<1033::AID-MRM7>3.0.CO
  • [9] 2-7
  • [10] Material differentiation by dual energy CT: initial experience
    Johnson, Thorsten R. C.
    Krauss, Bernhard
    Sedlmair, Martin
    Grasruck, Michael
    Bruder, Herbert
    Morhard, Dominik
    Fink, Christian
    Weckbach, Sabine
    Lenhard, Miriam
    Schmidt, Bernhard
    Flohr, Thomas
    Reiser, Maximilian F.
    Becker, Christoph R.
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (06) : 1510 - 1517