Method to test the long-term stability of functional electrical stimulation via multichannel electrodes (e.g., applicable for laryngeal pacing) and to define best points for stimulation: in vivo animal analysis

被引:1
作者
Faenger, Bernd [1 ]
Arnold, Dirk [1 ,2 ]
Schumann, Nikolaus P. [1 ]
Guntinas-Lichius, Orlando [3 ]
Scholle, Hans-Christoph [1 ]
机构
[1] Friedrich Schiller Univ Jena, Div Motor Res Pathophysiol & Biomech, Dept Trauma Hand & Reconstruct Surg, Univ Hosp, Erfurter Str 35, D-07740 Jena, Germany
[2] Friedrich Schiller Univ Jena, Inst Systemat Zool & Evolutionary Biol, Phylet Museum, Jena, Germany
[3] Jena Univ Hosp, Dept Otorhinolaryngol, Jena, Germany
关键词
Larynx pacemaker; Functional electrical stimulation; Stimulation; Multichannel array electrode; EMG; Electromyography; Motor endplate; Motor point; Fatigue; Muscle; Sihler's staining; Animal; MOTOR POINTS; MUSCLE; LOCALIZATION; PATIENT; SURFACE;
D O I
10.1007/s00405-016-4202-3
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The study aim was to identify and analyze intramuscular electrically sensitive points. Electrically sensitive points are herein defined as positions, which allow muscles stimulation with a minimum possible fatigue for a maximum amount of time. A multichannel array electrode was used which could be interesting to retain the function of larynx muscle after paralysis. Eight array electrodes were implanted in the triceps brachii muscle of four rats. While being under anesthesia, the animals were intramuscularly stimulated at 16 different positions. Sihler's staining technique was used to make visible the nerves routes and the intramuscular position of the individual electrode plate. The positions of the motor end plates were determined by means of multichannel-electromyography. The positions that allow longest stimulation periods are located close to the points where the nerves enter the muscle. Stimulation at the position of the motor end plates does not result in stimulation periods above average. Locations initially causing strong muscle contractions are not necessarily identical to the ones allowing long stimulation periods. The animal model identified the stimulation points for minimal possible muscle fatigue stimulation as being located close to the points of entrance of the nerve into the muscle. Stimulation causing an initially strong contraction response is no indication of optimal location of the stimulation electrode in terms of chronic stimulation. The array electrode of this study could be interesting as a stimulation electrode for a larynx pacemaker.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 26 条
[1]   Atlas of the muscle motor points for the lower limb: implications for electrical stimulation procedures and electrode positioning [J].
Botter, Alberto ;
Oprandi, Gianmose ;
Lanfranco, Fabio ;
Allasia, Stefano ;
Maffiuletti, Nicola A. ;
Minetto, Marco Alessandro .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (10) :2461-2471
[2]   Phrenic nerve pacing in a tetraplegic patient via intramuscular diaphragm electrodes [J].
DiMarco, AF ;
Onders, RP ;
Kowalski, KE ;
Miller, ME ;
Ferek, S ;
Mortimer, JT .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (12) :1604-1606
[3]   Development of a novel larynx pacemaker multichannel array electrode: In vivo animal analysis [J].
Faenger, Bernd ;
Schumann, Nikolaus P. ;
Arnold, Dirk ;
Grassme, Roland ;
Guntinas-Lichius, Orlando ;
Scholle, Hans-Christoph .
LARYNGOSCOPE, 2016, 126 (02) :429-436
[4]   RECRUITMENT PROPERTIES OF MONOPOLAR AND BIPOLAR EPIMYSIAL ELECTRODES [J].
GRANDJEAN, PA ;
MORTIMER, JT .
ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (01) :53-66
[5]  
Kamen G., 2009, Essentials of Electromyography, Vfirst
[6]   REDUCING MUSCLE FATIGUE IN FES APPLICATIONS BY STIMULATING WITH N-LET PULSE TRAINS [J].
KARU, ZZ ;
DURFEE, WK ;
BARZILAI, AM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (08) :809-817
[7]   Evaluation of a deep brain stimulation electrode for laryngeal pacing [J].
Katada, Akihiro ;
Van Himbergen, Daniel ;
Kunibe, Isamu ;
Nonaka, Satoshi ;
Harabuchi, Yasuaki ;
Huang, Shan ;
Billante, Cheryl R. ;
Zealear, David L. .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (08) :621-629
[8]   ELECTRODE CHARACTERIZATION FOR FUNCTIONAL APPLICATION TO UPPER EXTREMITY FNS [J].
KILGORE, KL ;
PECKHAM, PH ;
KEITH, MW ;
THROPE, GB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :12-21
[9]   SYNTHESIS OF HAND GRASP USING FUNCTIONAL NEUROMUSCULAR STIMULATION [J].
KILGORE, KL ;
PECKHAM, PH ;
THROPE, GB ;
KEITH, MW ;
GALLAHERSTONE, KA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (07) :761-770
[10]   Anatomic Localization of Motor Points of Hip Adductors [J].
Kwon, Jeong-Yi ;
Kim, Joon-Sung ;
Lee, Won Ihl .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2009, 88 (04) :336-341