Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels

被引:34
作者
Dimitrova, N. A. [1 ]
Arabadzhiev, T. I. [1 ]
Hogrel, J. -Y. [2 ]
Dimitrov, G. V. [1 ]
机构
[1] Bulgarian Acad Sci, Ctr Biomed Engn, BU-1113 Sofia, Bulgaria
[2] GH Pitie Salpetriere, Inst Myol, F-75651 Paris, France
关键词
Muscle fatigue; Isometric contraction; Longitudinal electrode position; Interference EMG; Spectral indices; Peripheral factors; Central factors; SKELETAL-MUSCLE FIBER; M-WAVE CHANGES; EXTRACELLULAR POTENTIALS; POWER SPECTRA; CHARACTERISTIC FREQUENCIES; ELECTRODE LOCATION; FUNCTIONAL-STATE; FINITE-LENGTH; SURFACE EMG; STIMULATION;
D O I
10.1016/j.jelekin.2007.08.007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The aim of the present study was to test the applicability of indices of muscle fatigue to interference EMG signals detected at various distances from the end-plate region during isometric voluntary contractions at different force levels. Bar electrode with 12 leading off surfaces and 5 mm inter-pole distance was used to detect EMG from human m. biceps brachii. The sensitivity of the new spectral indices to detect muscle fatigue was higher than that of mean or median frequencies. Considerable variations in the characteristic frequencies and values of spectral indices that could reflect recruitment and/or rotation of MUs were found under submaximal efforts. The increase of the indices was considered as a sign of peripheral muscle fatigue while their decreasing could be a sign of de-recruitment of fatigued or/and recruitment of new MUs reflecting central fatigue. The sensitivity of the indices to fatigue depended on the electrode arrangement and its longitudinal position in respect of the end-plate region and ends of the muscle fibres. It was larger for the electrodes placed in the middle of the semi-fibre. To overcome the problem with inappropriate position of the electrode, one could use an electrode whose longitudinal dimension would cover the entire semi-length of the analyzed fibres. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 27 条
[1]   Simulation analysis of the performance of a novel high sensitive spectral index for quantifying M-wave changes during fatigue [J].
Arabadzhiev, TI ;
Dimitrov, GV ;
Dimitrova, NA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (02) :149-158
[2]   Intracellular action potential generation and extinction strongly affect the sensitivity of M-wave characteristic frequencies to changes in the peripheral parameters with muscle fatigue [J].
Arabadzhiev, TI ;
Dimitrov, GV ;
Dimitrova, NA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (02) :159-169
[3]   Simulation analysis of interference EMG during fatiguing voluntary contractions. Part II - Changes in amplitude and spectral characteristics [J].
Dimitrov, G. V. ;
Arabadzhiev, T. I. ;
Hogrel, J. -Y. ;
Dimitrova, N. A. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (01) :35-43
[4]   Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length Part II: Effect of parameters altering with functional state [J].
Dimitrov, GV ;
Dimitrova, NA .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (09) :702-707
[5]   Effect of parameters altering with muscle fibre functional state on power spectra of spatially filtered extracellular potentials [J].
Dimitrov, G.V. ;
Dimitrova, N.A. .
Journal of Medical Engineering and Technology, 2001, 25 (02) :74-78
[6]   Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length - Part I: Effect of fibre anatomy [J].
Dimitrov, GV ;
Dimitrova, NA .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (08) :580-587
[7]  
DIMITROV GV, 2006, MED SCI SPORTS EXERC, V38, P1079
[8]   Estimate of M-wave changes in human biceps brachii during continuous stimulation [J].
Dimitrova, NA ;
Hogrel, JY ;
Arabadzhiev, TI ;
Dimitrov, GV .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (04) :341-348
[9]   Interpretation of EMG changes with fatigue: facts, pitfalls, and fallacies [J].
Dimitrova, NA ;
Dimitrov, GV .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (01) :13-36
[10]  
Dimitrova NA, 2001, J MED ENG TECHNOL, V25, P34, DOI 10.1080/03091900010022201