Trifecta has lower gradient and less prosthesis-patient mismatch than Mosaic Ultra in the aortic position: A prospective randomized study

被引:14
作者
Braathen, Bjorn [1 ]
Husebye, Trygve [2 ]
Lunde, Ida G. [3 ,4 ,5 ]
Tonnessen, Theis [1 ,5 ]
机构
[1] Oslo Univ Hosp, Dept Cardiothorac Surg, Ulleval, Norway
[2] Oslo Univ Hosp, Dept Cardiol, Ulleval, Norway
[3] Inst Expt Med Res, Oslo, Norway
[4] Ctr Heart Failure Res, Oslo, Norway
[5] Univ Oslo, Oslo, Norway
关键词
aortic valve; transvalvular gradient; prosthesis-patient mismatch; VALVE-REPLACEMENT; HEMODYNAMIC PERFORMANCE; PORCINE BIOPROSTHESIS; MAGNA EASE; STENOSIS; MULTICENTER; DURABILITY; EXPERIENCE; FREESTYLE; SURVIVAL;
D O I
10.1016/j.jtcvs.2018.11.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: When aortic valve replacement is needed, a biological valve is usually implanted in patients older than age 60 to 65 years. A large valvular opening area is important to avoid prosthesispatient mismatch and facilitate reverse left ventricular remodeling. The Trifecta biological valve (St Jude Medical, St Paul, Minn) is, because of its design, believed to reduce transvalvular gradient compared with other biological valves, especially in smaller annuli. Several retrospective studies have compared transvalvular gradients of implanted valves prostheses using the respective manufacturers given size and not the actual annulus size measured by a metric sizer. This makes comparison of the hemodynamic properties of different valve brands and sizes difficult. We therefore performed a prospective randomized study, using the same metric sizer to measure annulus size, and compared hemodynamic profiles of the Trifecta to our standard Mosaic Ultra biological valve (Medtronic, Minneapolis, Minn). Methods: Ninety elective patients with small to medium annulus diameter undergoing aortic valve replacement were randomized to either Trifecta or Mosaic Ultra. After native valve removal and decalcification, a Hegar-sizer was used to measure true annulus size. Then the largest possible valve of either brand was implanted according to the randomization protocol. Echocardiography was performed 6 months postoperatively. Results: Baseline parameters of the 2 cohorts were comparable. There were lower transvalvular gradients in the Trifecta compared with the Mosaic Ultra group for the given annulus sizes. Severe prosthesis-patient mismatch was present in 28% of patients in the Mosaic group and 3% of patients in the Trifecta group. Conclusions: Trifecta showed lower transvalvular gradients and less severe prosthesispatient mismatch compared with Mosaic Ultra for the given annulus sizes.
引用
收藏
页码:1032 / 1039
页数:8
相关论文
共 31 条
[1]   Long-term results of the Medtronic Mosaic porcine bioprosthesis in the aortic position [J].
Anselmi, Amedeo ;
Flecher, Erwan ;
Ruggieri, Vito Giovanni ;
Harmouche, Majid ;
Langanay, Thierry ;
Corbineau, Herve ;
Verhoye, Jean-Philippe ;
Leguerrier, Alain .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (06) :1884-1891
[2]   Randomized comparison of exercise haemodynamics of Freestyle, Magna Ease and Trifecta bioprostheses after aortic valve replacement for severe aortic stenosisaEuro [J].
Bach, David S. ;
Patel, Himanshu J. ;
Kolias, Theodore J. ;
Deeb, G. Michael .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (02) :361-367
[3]   Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :1-25
[4]   The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study [J].
Bavaria, Joseph E. ;
Desai, Nimesh D. ;
Cheung, Anson ;
Petracek, Michael R. ;
Groh, Mark A. ;
Borger, Michael A. ;
Schaff, Hartzell V. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (02) :590-597
[5]   One single dose of histidine-tryptophan-ketoglutarate solution gives equally good myocardial protection in elective mitral valve surgery as repetitive cold blood cardioplegia: A prospective randomized study [J].
Braathen, Bjorn ;
Jeppsson, Anders ;
Schersten, Henrik ;
Hagen, Ole M. ;
Vengen, Oystein ;
Rexius, Helena ;
Lepore, Vincenzo ;
Tonnessen, Theis .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04) :995-1001
[6]   Cold blood cardioplegia reduces the increase in cardiac enzyme levels compared with cold crystalloid cardioplegia in patients undergoing aortic valve replacement for isolated aortic stenosis [J].
Braathen, Bjorn ;
Tonnessen, Theis .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (04) :874-880
[7]   Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series [J].
Deutsch, Marcus-Andre ;
Prinzing, Anatol ;
Fiegl, Kathrin ;
Wottke, Michael ;
Badiu, Catalin C. ;
Krane, Markus ;
Goppel, Gertrud ;
Bleiziffer, Sabine ;
Guenzinger, Ralf ;
Lange, Ruediger .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (06) :1691-1698
[8]  
Eichinger WB, 2004, J HEART VALVE DIS, V13, P382
[9]  
Eichinger WB, 2002, J HEART VALVE DIS, V11, P529
[10]   European experience with the Mosaic bioprosthesis [J].
Eichinger, WB ;
Botzenhardt, F ;
Gunzinger, R ;
Kemkes, BM ;
Sosnowski, A ;
Maïza, D ;
Coto, EO ;
Bleese, N .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) :333-339