Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags

被引:45
|
作者
Buckley, K. [1 ]
Atkins, C. G. [1 ,2 ]
Chen, D. [3 ,4 ]
Schulze, H. G. [1 ]
Devine, D. V. [3 ,4 ]
Blades, M. W. [2 ]
Turner, R. F. B. [1 ,2 ,5 ]
机构
[1] Univ British Columbia, Michael Smith Labs, 2185 East Mall, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Dept Chem, 2036 Main Mall, Vancouver, BC V6T 1Z1, Canada
[3] Univ British Columbia, Dept Pathol & Lab Med, 2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada
[4] Univ British Columbia, Ctr Blood Res, 2350 Hlth Sci Mall, Vancouver, BC V6T 1Z3, Canada
[5] Univ British Columbia, Dept Elect & Comp Engn, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
RAMAN-SPECTROSCOPY; WHOLE-BLOOD; STORAGE; HEMOGLOBIN; FRESH; AGE;
D O I
10.1039/c5an02461g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 degrees C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.
引用
收藏
页码:1678 / 1685
页数:8
相关论文
共 50 条
  • [21] LABELED RED BLOOD CELL SCINTIGRAPHY IN THE NON-INVASIVE DIAGNOSTICS OF ENDOMETRIOSIS
    Demirel, F.
    Koca, G.
    Demirel, K.
    Aydogmus, H.
    Korkmaz, M.
    Gokmen, B.
    FERTILITY AND STERILITY, 2010, 94 (04) : S202 - S202
  • [22] Raman spectroscopy of stored red blood cells: evaluating clinically relevant biochemical markers in donated blood
    Atkins, Chad G.
    Buckley, Kevin
    Chen, Deborah
    Schulze, H. Georg
    Devine, Dana V.
    Blades, Michael W.
    Turner, Robin F. B.
    CLINICAL AND BIOMEDICAL SPECTROSCOPY AND IMAGING IV, 2015, 9537
  • [23] Direct biochemical characterization of stored red blood cells using Raman spectroscopy
    Gautham, Rekha
    Oh, Joo-Yeun
    Patel, Rakesh
    Dluhy, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [24] Non-invasive blood glucose in vivo detection based on photoacoustic spectroscopy
    Lü P.-F.
    Lu Z.-Q.
    He Q.-Z.
    Wang Q.
    Zhao H.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (06): : 1301 - 1308
  • [25] Non-Invasive Blood Glucose Monitoring Using Near Infrared Spectroscopy
    Gayathri, B.
    Sruthi, K.
    Menon, K. A. Unnikrishna
    2017 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2017, : 1139 - 1142
  • [26] Occlusion spectroscopy as a new paradigm for non-invasive blood measurements.
    Fine, I
    Fikhte, B
    Shvartsman, LD
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING, 2001, 4263 : 122 - 130
  • [27] Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements
    Dingari, Narahara Chari
    Barman, Ishan
    Singh, Gajendra P.
    Kang, Jeon Woong
    Dasari, Ramachandra R.
    Feld, Michael S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2871 - 2880
  • [28] The effects of pen ink and surface disinfectants on red blood cells stored in plasticized polyvinylchloride transfusion bags
    Uy, Ralph Justin
    Serrano, Katherine
    Hadjesfandiari, Narges
    Shih, Andrew W.
    Devine, Dana
    TRANSFUSION, 2024, 64 (01) : 141 - 149
  • [29] Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
    Wrobel, Maciej S.
    Kim, Jeong Hee
    Raj, Piyush
    Barman, Ishan
    Smulko, Janusz
    BIOSENSORS & BIOELECTRONICS, 2021, 180
  • [30] Non-Invasive Blood Glucose Monitor Based on Spectroscopy Using a Smartphone
    Dantu, Vishnu
    Vempati, Jagannadh
    Srivilliputhur, Srinivasan