Optimization of background electrolyte composition for simultaneous contactless conductivity and fluorescence detection in capillary electrophoresis of biological samples

被引:11
|
作者
Lacna, Julia [1 ,2 ]
Prikryl, Jan [3 ]
Teshima, Norio [4 ]
Murakami, Hiroya [4 ]
Esaka, Yukihiro [5 ]
Foret, Frantisek [1 ,3 ]
Kuban, Petr [1 ,3 ]
机构
[1] CEITEC Masaryk Univ, Dept Bioanalyt Instrumentat, Brno, Czech Republic
[2] Masaryk Univ, Dept Chem, Brno, Czech Republic
[3] Czech Acad Sci, Dept Bioanalyt Instrumentat, Inst Analyt Chem, Brno, Czech Republic
[4] Aichi Inst Technol, Dept Appl Chem, Toyota, Japan
[5] Gifu Pharmaceut Univ, Gifu, Japan
关键词
Capillary electrophoresis; Contactless conductivity detection; Dual detection; Laser induced fluorescence detection; Saliva; LASER-INDUCED FLUORESCENCE; EXHALED BREATH CONDENSATE; CONDUCTOMETRIC DETECTOR; SENSITIVE DETERMINATION; DUAL DETECTION; AMINO-ACIDS; CATIONS; ANIONS; CE; ANTIOXIDANTS;
D O I
10.1002/elps.201900112
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual (CD)-D-4-LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2-[4-(2-hydroxyethyl)piperazin-1-yl]ethanesulfonic acid, 15 mM 2-amino-2-hydroxymethyl-propane-1,3-diol, and 2 mM 18-crown-6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min. The samples were injected hydrodynamically from both capillary ends using the double-opposite end injection principle. Sensitive detection of anions, cations, and organic acids with micromolar LODs using (CD)-D-4 and simultaneously glutathione with nanomolar LODs using LIF was achieved in a single run. The developed BGE may be useful in analyses of biological samples containing analytes with differing concentrations of several orders of magnitude that is not possible with single detection mode.
引用
收藏
页码:2390 / 2397
页数:8
相关论文
共 50 条
  • [1] Simultaneous light emitting diode-induced fluorescence and contactless conductivity detection for capillary electrophoresis
    Tan, F
    Yang, BC
    Guan, YF
    ANALYTICAL SCIENCES, 2005, 21 (05) : 583 - 585
  • [2] Simultaneous Light Emitting Diode-Induced Fluorescence and Contactless Conductivity Detection for Capillary Electrophoresis
    Feng Tan
    Bingcheng Yang
    Yafeng Guan
    Analytical Sciences, 2005, 21 : 583 - 585
  • [3] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [4] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [5] Optimization of separation of heavy metals by capillary electrophoresis with contactless conductivity detection
    Lau, Hiu Fung
    Quek, Ngee Mian
    Law, Wai Siang
    Zhao, Jian Hong
    Hauser, Peter C.
    Li, Sam Fong Yau
    ELECTROPHORESIS, 2011, 32 (10) : 1190 - 1194
  • [6] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [7] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [8] Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples
    Pormsila, Worapan
    Morand, Rejane
    Kraehenbuehl, Stephan
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 921 - 926
  • [9] Considerations on contactless conductivity detection in capillary electrophoresis
    Baltussen, E
    Guijt, RM
    van der Steen, G
    Laugere, F
    Baltussen, S
    van Dedem, GWK
    ELECTROPHORESIS, 2002, 23 (17) : 2888 - 2893
  • [10] Sensitive Simultaneous Determination of Synthetic Food Colorants in Preserved Fruit Samples by Capillary Electrophoresis with Contactless Conductivity Detection
    Jia Yi
    Lewei Zeng
    Qiyan Wu
    Lirong Yang
    Tianyao Xie
    Food Analytical Methods, 2018, 11 : 1608 - 1618