The role of energy storage systems in resilience enhancement of health care centers with critical loads

被引:38
|
作者
Liu, Jun [1 ,2 ]
Jian, Lirong [1 ]
Wang, Wenting [1 ,3 ]
Qiu, Zumeng [1 ]
Zhang, Jianjun [4 ]
Dastbaz, Parisa [5 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Sch Econ & Management, Nanjing, Peoples R China
[2] Hanjing Project Management Co Ltd, Jinan, Peoples R China
[3] Taiyuan Inst Technol, Dept Econ & Management, Taiyuan, Peoples R China
[4] Water Affairs Bur Lixia Dist, Jinan, Peoples R China
[5] Tarbiat Modares Univ, Fac Ind & Syst Engn, Tehran, Iran
来源
JOURNAL OF ENERGY STORAGE | 2021年 / 33卷
关键词
Energy storage system; Resilience; Microgrid; Techno-economic analysis; Renewable energy source; TECHNOECONOMIC ASSESSMENT; POWER-SYSTEM; MICROGRIDS; DESIGN; WEATHER;
D O I
10.1016/j.est.2020.102086
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the spread of pandemic coronavims disease (COVID-19), health care centers have been encountered an increasing number of infected patients. Therefore, the resilience of hospitals during unpredicted power outages would be a concerning issue that need to be addressed appropriately. Electricity outage can endanger patients' lives, especially those who have needed immediate special care. In this study, a hybrid micmgrid (MG) including renewable energy sources (RESs), energy storage systems (ESSs), and diesel generators (DGs) is proposed to enhance the hospital's resilience during unpredicted power outages. To evaluate the resilience performance of the proposed MG, random outages are generated in different days of the year. Furthermore, a resilience index is introduced to measure the amount of unmet electrical load demand. Based on the optimization results, the resilient configuration consists of the wind turbine (WT) system, DG, ESS, and bi-directional converter. However, the optimum economic configuration is based on WT, DG, and bi-directional converter. In the resilient configuration, the WT system supplies most of the load demand over the optimization year. The surplus generated electricity by the WT system is directly sold-back to the main grid based on the predefined feed-in-tariff (FiT) rate. Simulation results show that the optimal operation of the ESS has improved the resilience of MG during unpredicted grid outages. The reliability of the hospital is also increased by considering ESS and DG in the architecture of the MG. The net present cost (NPC) and the cost of energy (COE) of the proposed system are 103,507 US$ and 272x10(-6) US$/kW, respectively. Optimization results based on the grid-load system as the base case and those of hybrid energy systems indicates that the utilization of the ESS has led to an increase in NPC and COE of the resilient MG. Moreover, the proposed resilient MG produces fewer greenhouse emissions in comparison with optimum economic configuration regarding the ESS utilization. The results of sensitivity analysis on the number and duration of outages indicate the significant effect of grid outages on the configuration and economic of the system.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Grid Resilience Enhancement and Stability Improvement of an Autonomous DC Microgrid Using a Supercapacitor-Based Energy Storage System
    Wang, Li
    Peng, Xian-Lun
    Li, Ting-You
    Hsu, Yu-Cheng
    Tseng, Ching-Chung
    Prokhorov, Anton V.
    Mokhlis, Hazlie
    Chua, Kein Huat
    Tripathy, Manoj
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (02) : 1975 - 1985
  • [32] Resilience Enhancement with Transportable Storage Systems and Repair Crews in Coupled Transportation and Distribution Networks
    Noutash, Ali
    Kalantar, Mohsen
    SUSTAINABLE CITIES AND SOCIETY, 2023, 99
  • [33] Resilience Oriented Planning of Urban Multi-Energy Systems With Generalized Energy Storage Sources
    Huang, Wujing
    Zhang, Xi
    Li, Kangping
    Zhang, Ning
    Strbac, Goran
    Kang, Chongqing
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2022, 37 (04) : 2906 - 2918
  • [34] Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage
    Hutchinson, Spencer
    Heredia, Willy G. Bernal
    Ghatpande, Omkar A.
    2022 IEEE CONFERENCE ON TECHNOLOGIES FOR SUSTAINABILITY (SUSTECH), 2022, : 71 - 78
  • [35] Resilience-Driven Optimal Sizing of Energy Storage Systems in Remote Microgrids
    Picioroaga, Irina
    Luca, Madalina
    Tudose, Andrei
    Sidea, Dorian
    Eremia, Mircea
    Bulac, Constantin
    SUSTAINABILITY, 2023, 15 (22)
  • [36] From fragility to resilience: A systems approach to strengthen primary health care
    Lugten, Elizabeth
    Marcus, Rachel
    Bright, Rhea
    Maruf, Farzana
    Kureshy, Nazo
    FRONTIERS IN PUBLIC HEALTH, 2023, 10
  • [37] Improving Reliability and Stability of the Power Systems: A Comprehensive Review on the Role of Energy Storage Systems to Enhance Flexibility
    Islam, Muhammad Muzammal
    Yu, Tianyou
    Giannoccaro, Giovanni
    Mi, Yang
    la Scala, Massimo
    Nasab, Mohammad Rajabi
    Wang, Jie
    IEEE ACCESS, 2024, 12 : 152738 - 152765
  • [38] Sustainable microgrids with energy storage as a means to increase power resilience in critical facilities: An application to a hospital
    Lagrange, Alexis
    de Simon-Martin, Miguel
    Gonzalez-Martinez, Alberto
    Bracco, Stefano
    Rosales-Asensio, Enrique
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 119
  • [39] Resilience-centered optimal sizing and scheduling of a building-integrated PV-based energy system with hybrid adiabatic-compressed air energy storage and battery systems
    Bazdar, Elaheh
    Nasiri, Fuzhan
    Haghighat, Fariborz
    ENERGY, 2024, 308
  • [40] Resilience Enhancement Strategy for Distribution Network Considering Supporting Role of Micro Energy Grid
    Ge S.
    Zhang C.
    Liu H.
    Xu Z.
    Dianwang Jishu/Power System Technology, 2019, 43 (07): : 2306 - 2313