The role of energy storage systems in resilience enhancement of health care centers with critical loads

被引:38
|
作者
Liu, Jun [1 ,2 ]
Jian, Lirong [1 ]
Wang, Wenting [1 ,3 ]
Qiu, Zumeng [1 ]
Zhang, Jianjun [4 ]
Dastbaz, Parisa [5 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Sch Econ & Management, Nanjing, Peoples R China
[2] Hanjing Project Management Co Ltd, Jinan, Peoples R China
[3] Taiyuan Inst Technol, Dept Econ & Management, Taiyuan, Peoples R China
[4] Water Affairs Bur Lixia Dist, Jinan, Peoples R China
[5] Tarbiat Modares Univ, Fac Ind & Syst Engn, Tehran, Iran
来源
JOURNAL OF ENERGY STORAGE | 2021年 / 33卷
关键词
Energy storage system; Resilience; Microgrid; Techno-economic analysis; Renewable energy source; TECHNOECONOMIC ASSESSMENT; POWER-SYSTEM; MICROGRIDS; DESIGN; WEATHER;
D O I
10.1016/j.est.2020.102086
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the spread of pandemic coronavims disease (COVID-19), health care centers have been encountered an increasing number of infected patients. Therefore, the resilience of hospitals during unpredicted power outages would be a concerning issue that need to be addressed appropriately. Electricity outage can endanger patients' lives, especially those who have needed immediate special care. In this study, a hybrid micmgrid (MG) including renewable energy sources (RESs), energy storage systems (ESSs), and diesel generators (DGs) is proposed to enhance the hospital's resilience during unpredicted power outages. To evaluate the resilience performance of the proposed MG, random outages are generated in different days of the year. Furthermore, a resilience index is introduced to measure the amount of unmet electrical load demand. Based on the optimization results, the resilient configuration consists of the wind turbine (WT) system, DG, ESS, and bi-directional converter. However, the optimum economic configuration is based on WT, DG, and bi-directional converter. In the resilient configuration, the WT system supplies most of the load demand over the optimization year. The surplus generated electricity by the WT system is directly sold-back to the main grid based on the predefined feed-in-tariff (FiT) rate. Simulation results show that the optimal operation of the ESS has improved the resilience of MG during unpredicted grid outages. The reliability of the hospital is also increased by considering ESS and DG in the architecture of the MG. The net present cost (NPC) and the cost of energy (COE) of the proposed system are 103,507 US$ and 272x10(-6) US$/kW, respectively. Optimization results based on the grid-load system as the base case and those of hybrid energy systems indicates that the utilization of the ESS has led to an increase in NPC and COE of the resilient MG. Moreover, the proposed resilient MG produces fewer greenhouse emissions in comparison with optimum economic configuration regarding the ESS utilization. The results of sensitivity analysis on the number and duration of outages indicate the significant effect of grid outages on the configuration and economic of the system.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Optimizing the operation of energy storage embedded energy hub concerning the resilience index of critical load
    Khayatzadeh, Jafar
    Soleymani, Soodabeh
    Mozafari, Seyed Babak
    Shourkaei, Hosein Mohammadnezhad
    JOURNAL OF ENERGY STORAGE, 2022, 48
  • [22] Strategic dispatch of electric buses for resilience enhancement of urban energy systems
    Zhang, Xi
    Dong, Zihang
    Huangfu, Fenyu
    Ye, Yujian
    Strbac, Goran
    Kang, Chongqing
    APPLIED ENERGY, 2024, 361
  • [23] Game theoretical approach for critical sizing of energy storage systems for residential prosumers
    Gholami, M.
    Sanjari, M. J.
    Berrada, A.
    JOURNAL OF ENERGY STORAGE, 2023, 64
  • [24] A resilience-oriented optimal planning of energy storage systems in high renewable energy penetrated systems
    Oraibi, W. Abdulrazzaq
    Mohammadi-Ivatloo, B.
    Hosseini, S. H.
    Abapour, M.
    JOURNAL OF ENERGY STORAGE, 2023, 67
  • [25] Underground energy storage system supported resilience enhancement for power system in high penetration of renewable energy
    Qin, Boyu
    Shi, Wen
    Fang, Ruoquan
    Wu, Dongyang
    Zhu, Yu
    Wang, Hongzhen
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [26] Assessing impacts of energy storage on resilience of distribution systems against hurricanes
    Hieu T.NGUYEN
    John W.MUHS
    Masood PARVANIA
    Journal of Modern Power Systems and Clean Energy, 2019, 7 (04) : 731 - 740
  • [27] Wearable biosensor systems and resilience: a perfect storm in health care?
    Drury, Robert L.
    FRONTIERS IN PSYCHOLOGY, 2014, 5
  • [28] Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics
    Nazaralizadeh, Solmaz
    Banerjee, Paramarshi
    Srivastava, Anurag K.
    Famouri, Parviz
    ENERGIES, 2024, 17 (05)
  • [29] Enhancing resilience of distribution systems: Integrating mobile energy storage systems and information gap decision theory for uncertainty management
    Rajabzadeh, Mohammad
    Kalantar, Mohsen
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [30] Power Resilience Enhancement of a Residential Electricity User Using Photovoltaics and a Battery Energy Storage System under Uncertainty Conditions
    Manoj Kumar, Nallapaneni
    Ghosh, Aritra
    Chopra, Shauhrat S.
    ENERGIES, 2020, 13 (16)