The role of energy storage systems in resilience enhancement of health care centers with critical loads

被引:43
作者
Liu, Jun [1 ,2 ]
Jian, Lirong [1 ]
Wang, Wenting [1 ,3 ]
Qiu, Zumeng [1 ]
Zhang, Jianjun [4 ]
Dastbaz, Parisa [5 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Sch Econ & Management, Nanjing, Peoples R China
[2] Hanjing Project Management Co Ltd, Jinan, Peoples R China
[3] Taiyuan Inst Technol, Dept Econ & Management, Taiyuan, Peoples R China
[4] Water Affairs Bur Lixia Dist, Jinan, Peoples R China
[5] Tarbiat Modares Univ, Fac Ind & Syst Engn, Tehran, Iran
关键词
Energy storage system; Resilience; Microgrid; Techno-economic analysis; Renewable energy source; TECHNOECONOMIC ASSESSMENT; POWER-SYSTEM; MICROGRIDS; DESIGN; WEATHER;
D O I
10.1016/j.est.2020.102086
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the spread of pandemic coronavims disease (COVID-19), health care centers have been encountered an increasing number of infected patients. Therefore, the resilience of hospitals during unpredicted power outages would be a concerning issue that need to be addressed appropriately. Electricity outage can endanger patients' lives, especially those who have needed immediate special care. In this study, a hybrid micmgrid (MG) including renewable energy sources (RESs), energy storage systems (ESSs), and diesel generators (DGs) is proposed to enhance the hospital's resilience during unpredicted power outages. To evaluate the resilience performance of the proposed MG, random outages are generated in different days of the year. Furthermore, a resilience index is introduced to measure the amount of unmet electrical load demand. Based on the optimization results, the resilient configuration consists of the wind turbine (WT) system, DG, ESS, and bi-directional converter. However, the optimum economic configuration is based on WT, DG, and bi-directional converter. In the resilient configuration, the WT system supplies most of the load demand over the optimization year. The surplus generated electricity by the WT system is directly sold-back to the main grid based on the predefined feed-in-tariff (FiT) rate. Simulation results show that the optimal operation of the ESS has improved the resilience of MG during unpredicted grid outages. The reliability of the hospital is also increased by considering ESS and DG in the architecture of the MG. The net present cost (NPC) and the cost of energy (COE) of the proposed system are 103,507 US$ and 272x10(-6) US$/kW, respectively. Optimization results based on the grid-load system as the base case and those of hybrid energy systems indicates that the utilization of the ESS has led to an increase in NPC and COE of the resilient MG. Moreover, the proposed resilient MG produces fewer greenhouse emissions in comparison with optimum economic configuration regarding the ESS utilization. The results of sensitivity analysis on the number and duration of outages indicate the significant effect of grid outages on the configuration and economic of the system.
引用
收藏
页数:15
相关论文
共 54 条
[2]   Optimal design and analysis of grid-connected photovoltaic under different tracking systems using HOMER [J].
Al Garni, Hassan Z. ;
Awasthi, Anjali ;
Ramli, Makbul A. M. .
ENERGY CONVERSION AND MANAGEMENT, 2018, 155 :42-57
[3]   Optimization design and economic analysis of energy management strategy based on photovoltaic/energy storage for heterogeneous cellular networks using the HOMER model [J].
Alsharif, Mohammed H. .
SOLAR ENERGY, 2017, 147 :133-150
[4]  
[Anonymous], 2019, AHWAZ ELECT CEO POWE
[5]  
[Anonymous], 2020, OCHA REPORT DISASTER
[6]  
[Anonymous], 2020, MASIH DANESHVARI HOS
[7]  
[Anonymous], 2020, POWER OUTAGE WAS CAU
[8]  
[Anonymous], 2020, 60 COUNTRYS ELECT NE
[9]  
[Anonymous], 2020, IRAN RENEWABLE ENERG
[10]  
[Anonymous], 2020, POWER OUTAGES COMING