Off-line calibration and data analysis for the silicon beam telescope on the CERN H2 beam

被引:11
作者
Kortelainen, M. J. [1 ]
Lampen, T. [1 ]
Moilanen, H. [1 ]
Maenpaa, T. [1 ]
机构
[1] Helsinki Inst Phys, FIN-00014 Helsinki, Finland
关键词
Particle tracking telescope; Si particle detectors; Position resolution; Track reconstruction; Detector alignment; STRIP DETECTOR; PERFORMANCE; APV25;
D O I
10.1016/j.nima.2009.01.189
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Silicon Beam Telescope (SiBT07) at the CERN H2 beam is a position-sensitive beam telescope targeted for LHC upgrade tests. The telescope consists of eight consecutive silicon microstrip detectors and slots for two test detectors. This article describes the reconstruction of reference tracks with the CMS data analysis software CMSSW. The related data analysis and calibration procedures, including pedestal corrections, common-mode corrections, and track-based alignment, are also described. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:600 / 606
页数:7
相关论文
共 17 条
[1]  
[Anonymous], 6 WORKSH EL LHC EXP
[2]  
[Anonymous], 2006, CERNLHCC2006001 CMS, V1
[3]   Performance and calibration studies of silicon strip detectors in a test beam [J].
Banzuzi, K ;
Haapakorpi, M ;
Heikkinen, A ;
Heinonen, JV ;
Honkanen, A ;
Karimäki, V ;
Mäenpää, T ;
Pietarinen, E ;
Salomäki, T ;
Tuominiemi, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (03) :536-544
[4]  
Cowan G., 1998, Statistical data analysis
[5]  
DEMARTEAU M, 2003, 4308 DO
[6]   Design and results from the APV25, a deep sub-micron CMOS front-end chip for the CMS tracker [J].
French, MJ ;
Jones, LL ;
Morrissey, Q ;
Neviani, A ;
Turchetta, R ;
Fulcher, J ;
Hall, G ;
Noah, E ;
Raymond, M ;
Cervelli, G ;
Moreira, P ;
Marseguerra, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (02) :359-365
[7]   Performance of a CMS silicon strip detector module with APV25 readout [J].
Friedl, M ;
Bauer, T ;
Hrubec, J ;
Krammer, M ;
Pernicka, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 488 (1-2) :175-183
[8]   BEAM TEST-RESULTS OF AN ION-IMPLANTED CAPACITIVELY COUPLED SILICON STRIP DETECTOR PROCESSED ON A 100-MM SILICON-WAFER [J].
HIETANEN, I ;
LINDGREN, J ;
ORAVA, R ;
TUUVA, T ;
BRENNER, R ;
ANDERSSON, M ;
LEINONEN, K ;
RONKAINEN, H ;
TURALA, M ;
WEILHAMMER, P ;
DULINSKI, W ;
HUSSON, D ;
LOUNIS, A ;
SCHAEFFER, M ;
TURCHETTA, R ;
CHAUVEAU, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (03) :677-680
[9]  
JONES L, 2001, APV25S1 USER MANUAL
[10]   Explicit covariance matrix for particle measurement precision [J].
Karimaki, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (02) :284-292