Evaluation of piping damage in German nuclear power plants

被引:5
|
作者
Bieniussa, KW
Reck, H
机构
关键词
D O I
10.1016/S0029-5493(96)01312-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Information relating to piping damage in safety-relevant systems in German nuclear power plants with light water reactors (both pressurized water reactors (PWRs) and boiling water reactors (BWRs)) were analyzed with respect to the modes and the causes of damages. In general, the total range of observed piping damage is low. The incidents (82) in plants with PWRs affected mainly pipes with small diameters. Almost all damaged piping showed wall-penetrating cracks combined with leakages, which revealed the damage. Initial cracks at piping with larger diameters were discovered in isolated cases during in-service inspections. With regard to the incidents (71) in plants with BWRs, piping with small as well as large diameters was affected to different degrees. Wall-penetrating cracks combined with leakages were detected at piping with small diameters. For large-diameters pipes, cracks were indicated during in-service inspections and supplementary examinations. The results of the incident evaluations confirm the conservativeness of the safety concept chosen for the design of German nuclear power plants with light water reactors. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:15 / 32
页数:18
相关论文
共 50 条
  • [21] Safety of German Nuclear Power Plants.
    Birkhofer, A.
    Atw. Atomwirtschaft, Atomtechnik, 1987, 32 (10): : 474 - 480
  • [22] Precursor analyses for German nuclear power plants
    Babst, S.
    Gaenssmantel, G.
    Stueck, R.
    KERNTECHNIK, 2009, 74 (03) : 111 - 113
  • [23] Benchmark analysis on PFM analysis codes for aged piping of nuclear power plants
    Itoh, Hiroto
    Li, Yinsheng
    Osakabe, Kazuya
    Onizawa, Kunio
    Yoshimura, Shinobu
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (07) : 2055 - 2058
  • [25] NEW TECHNIQUES FOR NONDESTRUCTIVE TESTING OF PIPING SYSTEMS IN NUCLEAR-POWER-PLANTS
    ETTEMEYER, A
    NUCLEAR ENGINEERING AND DESIGN, 1993, 139 (02) : 183 - 185
  • [26] Benchmark analysis on PFM analysis codes for aged piping of nuclear power plants
    Hiroto Itoh
    Yinsheng Li
    Kazuya Osakabe
    Kunio Onizawa
    Shinobu Yoshimura
    Journal of Mechanical Science and Technology, 2012, 26 : 2055 - 2058
  • [27] STANDARDIZATION OF PIPING SUPPORTS IN NUCLEAR-POWER PLANTS USING PRETESTED COMPONENTS
    LAUER, J
    LABES, M
    HULSEN, H
    NUCLEAR ENGINEERING AND DESIGN, 1988, 108 (03) : 477 - 483
  • [28] A STUDY OF PIPING STRESS-ANALYSIS TECHNIQUES FOR NUCLEAR-POWER PLANTS
    MOHAMED, SA
    HERSH, LG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 96 - 96
  • [29] Seismic fragility analysis of seismically isolated nuclear power plants piping system
    Firoozabad, Ehsan Salimi
    Jeon, Bub-Gyu
    Choi, Hyoung-Suk
    Kim, Nam-Sik
    NUCLEAR ENGINEERING AND DESIGN, 2015, 284 : 264 - 279
  • [30] EVALUATION OF AGED STEAM PIPING MAKES FOR SAFER POWER-PLANTS
    WRAY, R
    BALASCHAK, JJ
    POWER ENGINEERING, 1987, 91 (08) : 26 - 30