Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations

被引:21
作者
Koenig, A. M. [1 ]
Maas, J. [1 ]
Viniol, S. [1 ]
Etzel, R. [2 ]
Fiebich, M. [1 ,2 ]
Thomas, R. P. [1 ]
Mahnken, A. H. [1 ]
机构
[1] Philipps Univ Marburg, Univ Hosp Marburg, Clin Diagnost & Intervent Radiol, Marburg, Germany
[2] Mittelhessen Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
关键词
Radiation protection; Interventional radiology; Radiation-absorbing pad; MEDICAL STAFF; CANCER-RISKS; PROTECTION; EXPOSURE; OPERATOR; DOSIMETRY; EFFICACY; SHIELD;
D O I
10.1016/j.ejrad.2020.109245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiation-absorbing pads are an additional possibility to reduce scattered radiation at its source. The goal of this study is to investigate the efficacy of a new reusable radiation-absorbing pad at its origin in an experimental setup. Material and methods: All measurements were carried out using a clinical angiography system with a standardized fluoroscopy protocol, different C-arm angulations and an anthropomorphic torso phantom as a scattering body. An ionization chamber was used to measure the radiation exposure at five different heights of a simulated operator during a simulated transfemoral angiography intervention. Measurements were carried out with and without radiation-absorbing pads with lead equivalents of 0.25 and 0.5 mm placed onto the scattering body. For all measurements a mobile acrylic shield and an under-table lead curtain was used. Results: At all operator heights from 100 to 165 cm a significant radiation dose reduction of up to 80.6 % < 0.01) using the radiation-absorbing pad was measured, when compared to no radiation-absorbing pad. At the height of 165 cm the radiation-absorbing pad with a lead equivalence of 0.5 mm showed a significant radiation dose reduction (51.4 %, p < 0.01) in comparison to a lead equivalence of 0.25 mm. Conclusion: The addition of a radiation-absorbing pad to the standard protection means results in a significant dose reduction for the operator, particularly for upper body parts.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Fighting the Gender Gap in Interventional Radiology: Facts and Fiction Relating to Radiation
    Jaschke, Werner
    Bartal, Gabriel
    Trianni, Annalisa
    Belli, Anna-Maria
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (08) : 1254 - 1256
  • [42] An initial investigation of a wireless patient radiation dosimeter for use in interventional radiology
    Yohei Inaba
    Koichi Chida
    Yuuki Murabayashi
    Mime Endo
    Kazuki Otomo
    Masayuki Zuguchi
    Radiological Physics and Technology, 2020, 13 : 321 - 326
  • [43] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Bartal, Gabriel
    Vano, Eliseo
    Paulo, Graciano
    Miller, Donald L.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (02) : 289 - 298
  • [44] Management of Patient and Staff Radiation Dose in Interventional Radiology: Current Concepts
    Gabriel Bartal
    Eliseo Vano
    Graciano Paulo
    Donald L. Miller
    CardioVascular and Interventional Radiology, 2014, 37 : 289 - 298
  • [45] Radiation safety in pediatric interventional radiology: Step Lightly
    Manrita Sidhu
    Pediatric Radiology, 2010, 40 : 511 - 513
  • [46] An audit of patient radiation doses in interventional radiology at a South African hospital
    Slave, Oneile
    Mahomed, Nasreen
    SA JOURNAL OF RADIOLOGY, 2023, 27 (01):
  • [47] CURRENT TRENDS OF RADIATION PROTECTION EQUIPMENT IN INTERVENTIONAL RADIOLOGY
    Budosova, Darina
    Horvathova, Martina
    Bardyova, Zuzana
    Balazs, Tibor
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (9-11) : 554 - 559
  • [48] Evaluation of UV-permeability and photo-oxidisability of organic ultraviolet radiation-absorbing coatings
    Li, Neng
    Chen, Yuhe
    Bao, Yongjie
    Zhang, Zeqian
    Wu, Zaixing
    Chen, Zhangmin
    APPLIED SURFACE SCIENCE, 2015, 332 : 186 - 191
  • [49] Occupational orthopedic problems and its relation to personal radiation protection in interventional radiology
    Koenig, A. M.
    Froehlich, L.
    Viniol, S.
    Thomas, R. P.
    Mahnken, A. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
  • [50] Radiation dose optimization in diagnostic and interventional radiology: Current issues and future perspectives
    Tsapaki, Virginia
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 16 - 21