Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations

被引:21
|
作者
Koenig, A. M. [1 ]
Maas, J. [1 ]
Viniol, S. [1 ]
Etzel, R. [2 ]
Fiebich, M. [1 ,2 ]
Thomas, R. P. [1 ]
Mahnken, A. H. [1 ]
机构
[1] Philipps Univ Marburg, Univ Hosp Marburg, Clin Diagnost & Intervent Radiol, Marburg, Germany
[2] Mittelhessen Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
关键词
Radiation protection; Interventional radiology; Radiation-absorbing pad; MEDICAL STAFF; CANCER-RISKS; PROTECTION; EXPOSURE; OPERATOR; DOSIMETRY; EFFICACY; SHIELD;
D O I
10.1016/j.ejrad.2020.109245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiation-absorbing pads are an additional possibility to reduce scattered radiation at its source. The goal of this study is to investigate the efficacy of a new reusable radiation-absorbing pad at its origin in an experimental setup. Material and methods: All measurements were carried out using a clinical angiography system with a standardized fluoroscopy protocol, different C-arm angulations and an anthropomorphic torso phantom as a scattering body. An ionization chamber was used to measure the radiation exposure at five different heights of a simulated operator during a simulated transfemoral angiography intervention. Measurements were carried out with and without radiation-absorbing pads with lead equivalents of 0.25 and 0.5 mm placed onto the scattering body. For all measurements a mobile acrylic shield and an under-table lead curtain was used. Results: At all operator heights from 100 to 165 cm a significant radiation dose reduction of up to 80.6 % < 0.01) using the radiation-absorbing pad was measured, when compared to no radiation-absorbing pad. At the height of 165 cm the radiation-absorbing pad with a lead equivalence of 0.5 mm showed a significant radiation dose reduction (51.4 %, p < 0.01) in comparison to a lead equivalence of 0.25 mm. Conclusion: The addition of a radiation-absorbing pad to the standard protection means results in a significant dose reduction for the operator, particularly for upper body parts.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Personal Radiation Protection and Corresponding Dosimetry in Interventional Radiology: An Overview and Future Developments
    Koenig, Alexander Marc
    Etzel, Robin
    Thomas, Rohit Philip
    Mahnken, Andreas H.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (06): : 512 - 521
  • [32] High filtration in interventional practices reduces patient radiation doses but not always scatter radiation doses
    Sanchez, Roberto M.
    Vano, Eliseo
    Salinas, Pablo
    Gonzalo, Nieves
    Escaned, Javier
    Fernandez, Jose M.
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117)
  • [33] Efficacy of Radiation Safety Glasses in Interventional Radiology
    Bart D. van Rooijen
    Michiel W. de Haan
    Marco Das
    Carsten W. K. P. Arnoldussen
    R. de Graaf
    Wim H. van Zwam
    Walter H. Backes
    Cécile R. L. P. N. Jeukens
    CardioVascular and Interventional Radiology, 2014, 37 : 1149 - 1155
  • [34] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [35] SCATTER RADIATION IN THE FLUOROSCOPY-GUIDED INTERVENTIONAL ROOM
    Bohari, Asmah
    Hashim, Suhairul
    Mustafa, Siti Norsyafiqah Mohd
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) : 397 - 402
  • [36] Occupational radiation exposure in vascular interventional radiology: A complete evaluation of different body regions
    Bacchim Neto, Fernando Antonio
    Fattori Alves, Allan Felipe
    Mascarenhas, Yvone Maria
    Nicolucci, Patricia
    de Pina, Diana Rodrigues
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (08): : 1019 - 1024
  • [37] A Portable Dosimetric System Based on a CMOS Image Sensor for Radiation Protection in Interventional Radiology
    Conti, E.
    Placidi, P.
    Magalotti, D.
    Bissi, L.
    Paolucci, M.
    Scorzoni, A.
    Servoli, L.
    2014 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) PROCEEDINGS, 2014, : 288 - 292
  • [38] A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations
    Abdelrahman, Mahmoud
    Lombardo, Pasquale
    Camp, Anna
    Duch, Maria A.
    Phillips, Christophe
    Seret, Alain
    Vanhavere, Filip
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 58 - 70
  • [39] Radiation metrics for vascular and interventional radiology procedures in a tertiary care institution
    Arabi, Mohammad
    Rajeh, Ali S.
    Alhendi, Nasser
    Alotaibi, Khalid T.
    Yahyan, Talal A.
    Alyousef, Khalid
    Ardah, Husam
    SAUDI MEDICAL JOURNAL, 2022, 43 (09) : 1035 - 1042
  • [40] Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures
    Efstathopoulos, E. P.
    Pantos, I.
    Andreou, M.
    Gkatzis, A.
    Carinou, E.
    Koukorava, C.
    Kelekis, N. L.
    Brountzos, E.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997) : 70 - 77