Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations

被引:21
|
作者
Koenig, A. M. [1 ]
Maas, J. [1 ]
Viniol, S. [1 ]
Etzel, R. [2 ]
Fiebich, M. [1 ,2 ]
Thomas, R. P. [1 ]
Mahnken, A. H. [1 ]
机构
[1] Philipps Univ Marburg, Univ Hosp Marburg, Clin Diagnost & Intervent Radiol, Marburg, Germany
[2] Mittelhessen Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
关键词
Radiation protection; Interventional radiology; Radiation-absorbing pad; MEDICAL STAFF; CANCER-RISKS; PROTECTION; EXPOSURE; OPERATOR; DOSIMETRY; EFFICACY; SHIELD;
D O I
10.1016/j.ejrad.2020.109245
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiation-absorbing pads are an additional possibility to reduce scattered radiation at its source. The goal of this study is to investigate the efficacy of a new reusable radiation-absorbing pad at its origin in an experimental setup. Material and methods: All measurements were carried out using a clinical angiography system with a standardized fluoroscopy protocol, different C-arm angulations and an anthropomorphic torso phantom as a scattering body. An ionization chamber was used to measure the radiation exposure at five different heights of a simulated operator during a simulated transfemoral angiography intervention. Measurements were carried out with and without radiation-absorbing pads with lead equivalents of 0.25 and 0.5 mm placed onto the scattering body. For all measurements a mobile acrylic shield and an under-table lead curtain was used. Results: At all operator heights from 100 to 165 cm a significant radiation dose reduction of up to 80.6 % < 0.01) using the radiation-absorbing pad was measured, when compared to no radiation-absorbing pad. At the height of 165 cm the radiation-absorbing pad with a lead equivalence of 0.5 mm showed a significant radiation dose reduction (51.4 %, p < 0.01) in comparison to a lead equivalence of 0.25 mm. Conclusion: The addition of a radiation-absorbing pad to the standard protection means results in a significant dose reduction for the operator, particularly for upper body parts.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians
    McCaffrey, J. P.
    Tessier, F.
    Shen, H.
    MEDICAL PHYSICS, 2012, 39 (07) : 4537 - 4546
  • [2] Radiation Protection in Interventional Radiology
    Garg, Tushar
    Shrigiriwar, Apurva
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (04) : 939 - 945
  • [3] Radiation exposure in interventional radiology
    Pinto, N. G. V.
    Braz, D.
    Vallim, M. A.
    Filho, L. G. P.
    Azevedo, F. S.
    Barroso, R. C.
    Lopes, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 586 - 590
  • [4] Radiation protection of patients in interventional radiology
    Roche, A.
    JOURNAL DE RADIOLOGIE, 2010, 91 (11): : 1231 - 1235
  • [5] Radiation protection in interventional radiology
    Johnson, DR
    Kyriou, J
    Morton, EJ
    Clifton, A
    Fitzgerald, M
    MacSweeney, E
    CLINICAL RADIOLOGY, 2001, 56 (02) : 99 - 106
  • [6] Use of a sterile, disposable, radiation-absorbing shield reduces occupational. exposure to scatter radiation during pectoral device implantation
    Simons, GR
    Orrison, WW
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06): : 726 - 729
  • [7] Effectiveness of a new radiation protection system in the interventional radiology setting
    Etzel, Robin
    Koenig, Alexander M.
    Keil, Boris
    Fiebich, Martin
    Mahnken, Andreas H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 56 - 61
  • [8] Exoskeleton System for Radiation Protection in Interventional Radiology
    Hosse, Clarissa
    Kolck, Johannes
    Can, Elif
    Fehrenbach, Uli
    Auer, Timo A.
    Pivetta, Fabio
    Collettini, Federico
    Gebauer, Bernhard
    de Bucourt, Maximilian
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2024, 49 (02): : 78 - 84
  • [9] Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite
    Panick, Catherine
    Wunderle, Kevin
    Sands, Mark
    Martin, Charles
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (12) : 1925 - 1934
  • [10] Assessment of radiation doses to cardiologists during interventional examinations
    Bor, D.
    Olgar, T.
    Onal, E.
    Caglan, A.
    Toklu, T.
    MEDICAL PHYSICS, 2009, 36 (08) : 3730 - 3736