Chondroitin sulfate and sulfated hyaluronan-containing collagen coatings of titanium implants influence peri-implant bone formation in a minipig model

被引:55
作者
Korn, P. [1 ]
Schulz, M. C. [1 ]
Hintze, V. [2 ]
Range, U. [3 ]
Mai, R. [1 ]
Eckelt, U. [1 ]
Schnabelrauch, M. [4 ]
Moeller, S. [4 ]
Becher, J. [4 ]
Scharnweber, D. [2 ]
Stadlinger, B. [5 ]
机构
[1] Tech Univ Dresden, Fac Med Carl Gustav Carus, Dept Oral & Maxillofacial Surg, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Max Bergmann Ctr Biomat, Insitute Mat Sci, D-01069 Dresden, Germany
[3] Tech Univ Dresden, Fac Med Carl Gustav Carus, Inst Med Informat & Biometry, D-01307 Dresden, Germany
[4] Innovent eV, Biomat Dept, D-07745 Jena, Germany
[5] Univ Zurich, Clin Craniomaxillofacial & Oral Surg, CH-8032 Zurich, Switzerland
关键词
dental implant; coating; osseointegration; chondroitin sulfate; sulfated hyaluronan; HYDROXYAPATITE-COATED IMPLANTS; OSTEOGENIC DIFFERENTIATION; MATRICES ENHANCE; DENTAL IMPLANTS; SURFACE; GLYCOSAMINOGLYCANS; QUANTITATION; OSSEOINTEGRATION; PROLIFERATION; PROTEOGLYCANS;
D O I
10.1002/jbm.a.34913
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An improved osseous integration of dental implants in patients with lower bone quality is of particular interest. The aim of this study was to evaluate the effect of artificial extracellular matrix implant coatings on early bone formation. The coatings contained collagen (coll) in conjunction with either chondroitin sulfate (CS) or sulfated hyaluronan (sHya). Thirty-six screw-type, grit-blasted, and acid-etched titanium implants were inserted in the mandible of 6 minipigs. Three surface states were tested: (1) uncoated control (2) coll/CS (3) coll/sHya. After healing periods of 4 and 8 weeks, bone implant contact (BIC), bone volume density (BVD) as well as osteoid related parameters were measured. After 4 weeks, control implants showed a BIC of 44% which was comparable to coll/CS coated implants (48%) and significantly higher compared to coll/sHya coatings (37%, p=0.012). This difference leveled out after 8 weeks. No significant differences could be detected for BVD values after 4 weeks and all surfaces showed reduced BVD values after 8 weeks. However, at that time, BVD around both, coll/CS (30%, p=0.029), and coll/sHya (32%, p=0.015), coatings was significantly higher compared to controls (22%). The osteoid implant contact (OIC) showed no significant differences after 4 weeks. After 8 weeks OIC for controls was comparable to coll/CS, the latter being significantly higher compared to coll/sHya (0.9% vs. 0.4%, p=0.012). There were no significant differences in osteoid volume density. In summary, implant surface coatings by the chosen organic components of the extracellular matrix showed a certain potential to influence osseointegration in vivo. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2334-2344, 2014.
引用
收藏
页码:2334 / 2344
页数:11
相关论文
共 63 条
  • [1] Survival of hydroxyapatite-coated implants: A meta-analytic review
    Albrektsson, T
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (12) : 1379 - 1380
  • [2] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [3] Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection
    Alsaadi, Ghada
    Quirynen, Marc
    Komarek, Arnost
    van Steenberghe, Daniel
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (07) : 610 - 617
  • [4] Heparin inhibits osteoclastic differentiation and function
    Ariyoshi, Wataru
    Takahashi, Tetsu
    Kanno, Takahiro
    Ichimiya, Hisashi
    Shinmyouzu, Kouhei
    Takano, Hiroshi
    Koseki, Takeyoshi
    Nishihara, Tatsuji
    [J]. JOURNAL OF CELLULAR BIOCHEMISTRY, 2008, 103 (06) : 1707 - 1717
  • [5] Synthesis of New Regioselectively Sulfated Hyaluronans for Biomedical Application
    Becher, Jana
    Moeller, Stephanie
    Weiss, Dieter
    Schiller, Juergen
    Schnabelrauch, Matthias
    [J]. MODERN TRENDS IN POLYMER SCIENCE-EPF 09, 2010, 296 : 446 - +
  • [6] Collageneous matrix coatings on titanium implants modified with decorin and chondroitin sulfate: Characterization and influence on osteoblastic cells
    Bierbaum, S
    Douglas, T
    Hanke, T
    Scharnweber, D
    Tippelt, S
    Monsees, TK
    Funk, RHW
    Worch, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 77A (03) : 551 - 562
  • [7] Modification of Ti6Al4V surfaces using collagen I, III, and fibronectin. I. Biochemical and morphological characteristics of the adsorbed matrix
    Bierbaum, S
    Beutner, R
    Hanke, T
    Scharnweber, D
    Hempel, U
    Worch, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (02): : 421 - 430
  • [8] Heparan sulphate proteoglycans fine-tune mammalian physiology
    Bishop, Joseph R.
    Schuksz, Manuela
    Esko, Jeffrey D.
    [J]. NATURE, 2007, 446 (7139) : 1030 - 1037
  • [9] Enhanced bone apposition to a chemically modified SLA titanium surface
    Buser, D
    Broggini, N
    Wieland, M
    Schenk, RK
    Denzer, AJ
    Cochran, DL
    Hoffmann, B
    Lussi, A
    Steinemann, SG
    [J]. JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) : 529 - 533
  • [10] Nanostructured ceramics for biomedical implants
    Catledge, SA
    Fries, MD
    Vohra, YK
    Lacefield, WR
    Lemons, JE
    Woodard, S
    Venugopalan, R
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2002, 2 (3-4) : 293 - 312