Development of an electrochemical flow injection immunoassay (FIIA) for the real-time monitoring of biospecific interactions

被引:54
作者
Killard, AJ
Zhang, SQ
Zhao, HJ
John, R
Iwuoha, EI
Smyth, MR [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
[2] Griffith Univ, Nathan, Qld 4111, Australia
[3] Univ W Indies, Dept Chem, St Augustine, Trinidad Tobago
关键词
flow injection; immunoassay; biosensor; screen printed electrode; polyaniline;
D O I
10.1016/S0003-2670(99)00611-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Not only are sensors a revolution in analysis; they themselves are also experiencing a revolution brought about by parallel developments in sensor fabrication techniques and materials, polymer chemistry, signal processing methodologies, the increased use of biomolecular processes as a means of analyte detection, and the coupling of sensors to other techniques such as flow injection analysis. Many of these developments have been incorporated into the present study, which we are undertaking in the development of our immunosensor technology. The system described here utilises screen-printed electrodes which are low-cost, disposable devices that are simple to fabricate. Incorporated into our sensor is the electroactive polymer, polyaniline, which brings about mediatorless redox coupling between the electrode and biomolecular components attached to the polymer surface. This system also utilises enzyme-labelled antibodies as the biomolecular recognition component for the analysis of the test analyte, biotin. The system has also been integrated into a flow injection system. This has led to the monitoring of real-time antibody-antigen interactions using electrochemical methods and foreshadows the development of single-step immunosensors. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 119
页数:11
相关论文
共 21 条
  • [1] Electrochemical characteristics of D-amino acid oxidase Immobilized in a conductive redox polymer
    Arai, G
    Noma, T
    Hayashi, M
    Yasumori, I
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 452 (01): : 43 - 48
  • [2] A microelectrochemical switch responsive to NADH
    Bartlett, PN
    Wang, JH
    Wallace, ENK
    [J]. CHEMICAL COMMUNICATIONS, 1996, (03) : 359 - 360
  • [3] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [4] DEVELOPMENT OF AN ANTIBODY-BASED BIOSENSOR FOR DETERMINATION OF 7-HYDROXYCOUMARIN (UMBELLIFERONE) USING HORSERADISH-PEROXIDASE LABELED ANTI-7-HYDROXYCOUMARIN ANTIBODY
    DEASY, B
    DEMPSEY, E
    SMYTH, MR
    EGAN, D
    BOGAN, D
    OKENNEDY, R
    [J]. ANALYTICA CHIMICA ACTA, 1994, 294 (03) : 291 - 297
  • [5] Second-order kinetic analysis of IAsys biosensor data: Its use and applicability
    Edwards, PR
    Maule, CH
    Leatherbarrow, RJ
    Winzor, DJ
    [J]. ANALYTICAL BIOCHEMISTRY, 1998, 263 (01) : 1 - 12
  • [6] Development of a highly sensitive enzyme-linked immunosorbent assay for atrazine - Performance evaluation by flow injection immunoassay
    Gascon, J
    Oubina, A
    Ballesteros, B
    Barcelo, D
    Camps, F
    Marco, MP
    GonzalezMartinez, MA
    Morais, S
    Puchades, R
    Maquieira, A
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 149 - 162
  • [7] Monoclonal antibody-based flow-through immunosensor for analysis of carbaryl
    GonzalezMartinez, MA
    Morais, S
    Puchades, R
    Maquieira, A
    Abad, A
    Montoya, A
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (14) : 2812 - 2818
  • [8] FLOW-INJECTION IMMUNOASSAYS
    GUBITZ, G
    SHELLUM, C
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 421 - 428
  • [9] SCREEN-PRINTED VOLTAMMETRIC AND AMPEROMETRIC ELECTROCHEMICAL SENSORS FOR DECENTRALIZED TESTING
    HART, JP
    WRING, SA
    [J]. ELECTROANALYSIS, 1994, 6 (08) : 617 - 624
  • [10] Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses
    Hart, JP
    Wring, SA
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (02) : 89 - 103