Calibrated Frequency-Division Distorted Born Iterative Tomography for Real-Life Head Imaging

被引:25
作者
Guo, L. [1 ]
Nguyen-Trong, N. [2 ]
Al-Saffar, A. [1 ]
Stancombe, A. [1 ]
Bialkowski, K. [1 ]
Abbosh, A. [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn ITEE, Brisbane, Qld 4072, Australia
[2] Univ Adelaide, Sch Elect & Elect Engn, Adelaide, SA 5000, Australia
关键词
Antenna measurements; Radio frequency; Transmitting antennas; Phantoms; Tomography; Microwave theory and techniques; Frequency measurement; microwave imaging; calibration; stroke imaging; MICROWAVE TOMOGRAPHY; INVERSION; SYSTEM; RECONSTRUCTION; ALGORITHM; SUPERRESOLUTION; RESOLUTION; PROTOTYPE;
D O I
10.1109/TMI.2021.3132000
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The clinical use of microwave tomography (MT) requires addressing the significant mismatch between simulated environment, which is used in the forward solver, and real-life system. To alleviate this mismatch, a calibrated tomography, which uses two homogeneous calibration phantoms and a modified distorted Born iterative method (DBIM), is presented. The two phantoms are used to derive a linear model that matches the forward solver to real-life measurements. Moreover, experimental observations indicate that signal quality at different frequencies varies between different antennas due to inevitably inconsistent manufacturing tolerance and variances in radio-frequency chains. An optimum frequency, at which the simulated and measured signals of the antenna present maximum similarity when irradiating the calibrated phantoms, is thus calculated for each antenna. A frequency-division DBIM (FD-DBIM), in which different antennas in the array transmit their corresponding optimum frequencies, is subsequently developed. A clinical brain scanner is then used to assess performance of the algorithm in lab and healthy volunteers' tests. The linear calibration model is first used to calibrate the measured data. After that FD-DBIM is used to solve the problem and map the dielectric properties of the imaged domain. The simulated and experimental results confirm validity of the presented approach and its superiority to other tomographic method.
引用
收藏
页码:1087 / 1103
页数:17
相关论文
共 66 条
[1]   Iterative forward and inverse algorithms based on domain integral equations for three-dimensional electric and magnetic objects [J].
Abubakar, A ;
van den Berg, PM .
JOURNAL OF COMPUTATIONAL PHYSICS, 2004, 195 (01) :236-262
[2]   Imaging of biomedical data using a multiplicative regularized contrast source inversion method [J].
Abubakar, A ;
van den Berg, PM ;
Mallorqui, JJ .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2002, 50 (07) :1761-1771
[3]   Modified Born Iterative Method in Medical Electromagnetic Tomography Using Magnetic Field Fluctuation Contrast Source Operator [J].
Afsari, Arman ;
Abbosh, Amin M. ;
Rahmat-Samii, Yahya .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2019, 67 (01) :454-463
[4]   Qualitative Microwave Imaging With Scattering Parameters Measurements [J].
Akinci, Mehmet Nuri ;
Caglayan, Tughan ;
Ozgur, Selcuk ;
Alkasi, Ugur ;
Ahmadzay, Habibullah ;
Abbak, Mehmet ;
Cayoren, Mehmet ;
Akduman, Ibrahim .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (09) :2730-2740
[5]   Microwave Tomography-Enhanced GPR in Forensic Surveys: The Case Study of a Tropical Environment [J].
Almeida, Emerson Rodrigo ;
Porsani, Jorge Luis ;
Catapano, Ilaria ;
Gennarelli, Gianluca ;
Soldovieri, Francesco .
IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2016, 9 (01) :115-124
[6]   Variable-Exponent Lebesgue-Space Inversion for Brain Stroke Microwave Imaging [J].
Bisio, Igor ;
Estatico, Claudio ;
Fedeli, Alessandro ;
Lavagetto, Fabio ;
Pastorino, Matteo ;
Randazzo, Andrea ;
Sciarrone, Andrea .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (05) :1882-1895
[7]   Brain Stroke Microwave Imaging by Means of a Newton-Conjugate-Gradient Method in Lp Banach Spaces [J].
Bisio, Igor ;
Estatico, Claudio ;
Fedeli, Alessandro ;
Lavagetto, Fabio ;
Pastorino, Matteo ;
Randazzo, Andrea ;
Sciarrone, Andrea .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (08) :3668-3682
[8]   Inversion of experimental multi-frequency data using the contrast source inversion method [J].
Bloemenkamp, RF ;
Abubakar, A ;
van den Berg, PM .
INVERSE PROBLEMS, 2001, 17 (06) :1611-1622
[9]   On the Opportunities and Challenges in Microwave Medical Sensing and Imaging [J].
Chandra, Rohit ;
Zhou, Huiyuan ;
Balasingham, Ilangko ;
Narayanan, Ram M. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (07) :1667-1682
[10]   Subspace-Based Optimization Method for Solving Inverse-Scattering Problems [J].
Chen, Xudong .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2010, 48 (01) :42-49