Development and validation of a fast and simple multi- analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC- MS and one- point calibration

被引:26
作者
Meyer, Golo M. J. [1 ]
Weber, Armin A. [1 ]
Maurer, Hans H. [1 ]
机构
[1] Univ Saarland, Dept Expt & Clin Toxicol, Inst Expt & Clin Pharmacol & Toxicol, D-66421 Homburg, Saar, Germany
关键词
poisoning; quantification; one-point calibration; validation; GC-MS; multi-analyte procedure; TANDEM MASS-SPECTROMETRY; LIBRARY-ASSISTED IDENTIFICATION; PRESSURE CHEMICAL-IONIZATION; HUMAN BLOOD-PLASMA; HUMAN SERUM; CLINICAL TOXICOLOGY; ANTIDEPRESSANTS; METABOLITES; URINE; TESTS;
D O I
10.1002/dta.1555
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:472 / 481
页数:10
相关论文
共 39 条
[1]  
[Anonymous], 2008, DTSCH ARZTEBLATT
[2]  
[Anonymous], 2011, MASS SPECTRAL GC DAT
[3]   Which drug tests in medical emergencies? [J].
Boyer, EW ;
Shannon, MW .
CLINICAL CHEMISTRY, 2003, 49 (03) :353-354
[4]   Development and practical application of a library of CID accurate mass spectra of more than 2,500 toxic compounds for systematic toxicological analysis by LC-QTOF-MS with data-dependent acquisition [J].
Broecker, Sebastian ;
Herre, Sieglinde ;
Wuest, Bernhard ;
Zweigenbaum, Jerry ;
Pragst, Fritz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) :101-117
[5]   Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAPA® LC-MS/MS system and library searching [J].
Dresen, S. ;
Ferreiros, N. ;
Gnann, H. ;
Zimmermann, R. ;
Weinmann, W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (07) :2425-2434
[6]   Screening of pesticides in blood with liquid chromatography-linear ion trap mass spectrometry [J].
Dulaurent, Sylvain ;
Moesch, Christian ;
Marquet, Pierre ;
Gaulier, Jean-Michel ;
Lachatre, Gerard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (06) :2235-2249
[7]  
Flanagan Robert J, 2004, Toxicol Rev, V23, P251, DOI 10.2165/00139709-200423040-00005
[8]   Development of an LC-MS/MS method for the quantitation of 55 compounds prescribed in combined cardiovascular therapy [J].
Gonzalez, Oskar ;
Maria Alonso, Rosa ;
Ferreiros, Nerea ;
Weinmann, Wolfgang ;
Zimmermann, Ralf ;
Dresen, Sebastian .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (3-4) :243-252
[9]   Quantitative determination of forty-eight antidepressants and antipsychotics in human serum by HPLC tandem mass spectrometry:: A multi-level, single-sample approach [J].
Kirchherr, H. ;
Kuehn-Velten, W. N. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 843 (01) :100-113
[10]   Screening, library-assisted identification and validated quantification of 23 benzodiazepines, flumazenil, zaleplone, zolpidem and zopiclone in plasma by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization [J].
Kratzsch, C ;
Tenberken, O ;
Peters, FT ;
Weber, AA ;
Kraemer, T ;
Maurer, HH .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (08) :856-872