Fixed-bed column study for hexavalent chromium removal and recovery by short-chain polyaniline synthesized on jute fiber

被引:144
作者
Kumar, Potsangbam Albino [1 ]
Chakraborty, Saswati [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Gauhati 781039, Assam, India
关键词
Chromium; Polyaniline; Breakthrough curve; BDST model; Dynamic bed capacity; GRANULAR ACTIVATED CARBON; AQUEOUS-SOLUTION; WASTE-WATER; METAL-IONS; ADSORPTION; BIOSORPTION; CR(VI); BATCH; REDUCTION; SORPTION;
D O I
10.1016/j.jhazmat.2008.05.147
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fixed-bed column studies were conducted to evaluate performance of a short-chain polymer, polyaniline, synthesized on the surface of jute fiber (PANI-jute) for the removal of hexavalent chromium [Cr(VI)] in aqueous environment. Influent pH, column bed depth, influent Cr(VI) concentrations and influent flow rate were variable parameters for the present study. Optimum pH for total chromium removal was observed as 3 by electrostatic attraction of acid chromate ion (HCrO4-) with protonated amine group (NH3+) Of PANI-jute. With increase in column bed depth from 40 to 60cm, total chromium uptake by PANI-jute increased from 4.14 to 4.66 mg/g with subsequent increase in throughput volume from 9.84 to 12.6 L at exhaustion point. The data obtained for total chromium removal were well described by BDST equation till 10% breakthrough. Adsorption rate constant and dynamic bed capacity at 10% breakthrough were observed as 0.01 L/mg h and 1069.46 mg/L, respectively. Adsorbed total chromium was recovered back from PANI-jute as non-toxic Cr(III) after ignition with more than 97% reduction in weight, minimizing the problem of solid waste disposal. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1086 / 1098
页数:13
相关论文
共 48 条